Journals / Düzce Üniversitesi Bilim ve Teknoloji Dergisi / 2020 / Cilt: 8 - Sayı: 3

A Vortex-Assisted Microextraction Based On Deep Eutectic Solvents for Determination of Four Parabens from Cosmetic Baby Oils and Optimization by Box-Behnken Design

Kozmetik Bebek Yağlarında Dört Parabenin Tayini için Derin Ötektik Çözücülere Dayanan Vorteks Destekli Mikro Ekstraksiyon ve BoxBehnken Tasarımı ile Optimizasyon

Pages
1936–1947
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This developed method isvery suitable and effective method for the extraction of parabens from cosmetic products of similar structure.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This study presents microextraction and determination of four parabens by vortex-assisted microextraction basedon deep eutectic solvents (DESs) in cosmetic baby oils.
📊
Key Findings & Data:The most suitable DES, ChCl-ethylene glycol moleratios of DES were determined as 1:2 for use in this study.
💡
Conclusion & Impact:This developed method isvery suitable and effective method for the extraction of parabens from cosmetic products of similar structure.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

This study presents microextraction and determination of four parabens by vortex-assisted microextraction basedon deep eutectic solvents (DESs) in cosmetic baby oils. The most suitable DES, ChCl-ethylene glycol moleratios of DES were determined as 1:2 for use in this study. The effect of DES types has been explored attraditional one factor experiment at a time. The effect of DES volume, dilution solvent volume and vortex timeon extraction recovery were examined and optimized by the Box-Behnken design. After optimum conditionswere determined, vortex-assisted microextraction based on DES, 0.1-100 µg mL-1concentration in the range ofthe calibration curve was plotted for all parabens. The recovery values of parabens in cosmetic baby oil sampleswere in the range of 82.02-101.95% and the RSDs were varied from 1.64% to 2.91%. This developed method isvery suitable and effective method for the extraction of parabens from cosmetic products of similar structure.

Özet

Bu çalışma kozmetik bebek yağlarında derin ötektik çözücülere (DES'ler) dayalı vorteks destekli mikroekstraksiyon ile dört parabenin mikro ekstraksiyonu ve tayinini sunmaktadır. En uygun DES, ChCl-etilen glikol mol oranları bu çalışmada kullanılmak üzere 1:2 olarak belirlenmiştir. DES türlerinin etkisi, geleneksel tek faktörlü deneyde araştırılmıştır. DES hacmi, seyreltme çözücü hacmi ve vorteks süresinin ekstraksiyon geri kazanımı üzerindeki etkisi Box-Behnken tasarımı ile incelenmiş ve optimize edilmiştir. Optimum koşullar belirlendikten sonra, DES'e dayalı vorteks destekli mikro ekstraksiyon, kalibrasyon eğrisi 0.1-100 µg mL-1 konsantrasyon tüm parabenler için çizildi. Kozmetik bebek yağı numunelerindeki parabenlerin geri kazanım değerleri % 82.02-101.95 aralığındadır ve RSD'ler %1.64 ile %2.91 arasında değişmektedir. Bu geliştirilen yöntem, benzer yapıdaki kozmetik ürünlerden parabenlerin ekstraksiyonu için çok uygun ve etkili bir yöntemdir.

🔖

Cite This Article

Özak, S. S. (2022). A Vortex-Assisted Microextraction Based On Deep Eutectic Solvents for Determination of Four Parabens from Cosmetic Baby Oils and Optimization by Box-Behnken Design. Düzce Üniversitesi Bilim ve Teknoloji Dergisi, Cilt: 8 - Sayı: 3, 1936–1947. https://ajindex.com/articles/494109

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. M. Esteki, S. Nouroozi, S. Amanifar, and Z. Shahsavari, “A Simple and Highly Sensitive Method for Quantitative Detection of Methyl Paraben and Phenol in Cosmetics Using Derivative Spectrophotometry and Multivariate Chemometric Techniques,” Journal of the Chinese Chemical Society, vol. 64, pp. 152-163, 2017
  2. C.F. Grecco, I.D. Souza, and M.E. C. Queiroz, “Recent Development of Chromatographic Methods to Determine Parabens in Breast Milk Samples: A Review,” Journal of Chromatography B, vol. 1093, pp. 82-90, 2018
  3. C. Freire, J. M. Molina-Molina, L. M. Iribarne-Durán, I. Jiménez-Díaz, F. Vela-Soria, V. Mustieles, and N. Olea, “Concentrations of Bisphenol A and Parabens in Socks for Infants and Young Children in Spain and Their Hormone-Like Activities,” Environment International, vol. 127, pp. 592- 600, 2019
  4. I. Van Overmeire, K. Vrijens, T. Nawrot, A. Van Nieuwenhuyse, J. Van Loco, and T. Reyns, “Simultaneous Determination of Parabens, Bisphenols and Alkylphenols in Human Placenta By UltraHigh Performance Liquid Chromatography-Tandem Mass Spectrometry,” Journal of Chromatography B, vol. 1121, pp. 96-102, 2019
  5. I. Gosens, C. J. Delmaar, W. Ter Burg, C. De Heer, and A. G. Schuur, “Aggregate Exposure Approaches for Parabens in Personal Care Products: A Case Assessment for Children Between 0 and 3 Years Old,” Journal of Exposure Science and Environmental Epidemiology, vol. 24, pp. 208-214, 2014
  6. T. Potouridis, E. Berger, and W. Püttmann, “Analysis of Alkyl Esters of P-Hydroxybenzoic Acid (Parabens) in Baby Teethers via Gas Chromatography-Quadrupole Mass Spectrometry (GCqMS) Using A Stable Isotope Dilution Assay (SIDA),” Analytical Methods, vol. 8, pp. 3466-3474, 2016
  7. E. Yıldız, and H. Çabuk, “Miniaturized Matrix Solid-Phase Dispersion Coupled with Supramolecular Solvent-Based Microextraction for the Determination of Paraben Preservatives in Cream Samples,” Journal of Separation Science, vol. 41, pp. 2750-2758, 2018
  8. C. W. Chen, W. C. Hsu, Y. C. Lu, J. R. Weng, and C. H. Feng, “Determination of Parabens Using Two Microextraction Methods Coupled with Capillary Liquid Chromatography-UV Detection,” Food Chemistry, vol. 241 pp. 411-418, 2018
  9. Q. Yin, Y. Zhu, and Y. Yang, “Dispersive Liquid–Liquid Microextraction Followed By Magnetic Solid-Phase Extraction for Determination of Four Parabens in Beverage Samples By UltraPerformance Liquid Chromatography Tandem Mass Spectrometry,” Food Analytical Methods, vol. 11 pp. 797-807, 2018. [10]