Journals / Diagnostic and Interventional Radiology / 2022 / Cilt: 28 - Sayı: 1

Techniques in adrenal vein sampling: Multipurpose catheter shape facilitates sampling of cranially oriented right adrenal veins

Pages
79–82
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Multipurpose catheters should be readily considered when cranially oriented RAVs are present and when caudally oriented catheters fail to identify the RAV.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Adrenal vein sampling (AVS) failure is often attributed to difficulty in sampling the right adrenal vein (RAV).
📊
Key Findings & Data:Between 2014 and 2019, 351 patients underwent AVS and RAV sampling, with a multipurpose catheter used in 23 patients (7%, 10 male, 13 female patients).
💡
Conclusion & Impact:Multipurpose catheters should be readily considered when cranially oriented RAVs are present and when caudally oriented catheters fail to identify the RAV.
🔬Design:Research Article
📍Scope:2014 Verileri
⚙️Variables:Domain Parameters

Abstract

Adrenal vein sampling (AVS) failure is often attributed to difficulty in sampling the right adrenal vein (RAV). Normally, the RAV is caudally oriented; however, cranial orientation of the RAV is not uncommon. In such cases, use of a multipurpose catheter may facilitate sampling. Between 2014 and 2019, 351 patients underwent AVS and RAV sampling, with a multipurpose catheter used in 23 patients (7%, 10 male, 13 female patients). Data regarding pre-AVS imaging, procedural details, and AVS results were collected, the RAV vertical angle was measured on venography using the inferior vena cava (IVC) right lateral wall as the craniocaudal axis (0° defined as caudal, 180° cranial), and correlation between the number of catheters used until successful sampling with the multipurpose catheter and various procedural measures was assessed. Twenty-four technically successful AVS procedures were performed in 23 patients, all of whom had cranially oriented RAVs on intra-procedural venography. A multipurpose catheter was the first choice in 2 patients with previously known cranially oriented RAVs. In the remaining patients, the multipurpose catheter was the second choice in 21% (n = 5), third choice in 50% (n = 12), and up to the eighth choice (n = 1). Early utilization of the multipurpose catheter correlated with lower fluoroscopic time (r = .71, P = .0001) and lower contrast volume (r = .77, P < .0001). These results support the use of the multipurpose catheter when sampling cranially oriented RAVs. Multipurpose catheters should be readily considered when cranially oriented RAVs are present and when caudally oriented catheters fail to identify the RAV.

🔖

Cite This Article

DePIETRO, D. M., TREROTOIA, S. O. (2022). Techniques in adrenal vein sampling: Multipurpose catheter shape facilitates sampling of cranially oriented right adrenal veins. Diagnostic and Interventional Radiology, Cilt: 28 - Sayı: 1, 79–82. https://ajindex.com/articles/487256

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Trerotola SO, Asmar M, Yan Y, Fraker DL, Cohen DL. Failure mode analysis in adrenal vein sampling: a single-center experience. J Vasc Interv Radiol. 2014
  2. 25(10):1611-1619. [CrossRef] 2. Daunt N. Adrenal vein sampling: how to make it quick, easy, and successful. RadioGraphics. 2005
  3. 25(Suppl 1):S143-S158. [CrossRef] 3. Kahn SL, Angle JF. Adrenal vein sampling. Tech Vasc Interv Radiol. 2010
  4. 13(2):110-125. [CrossRef] 4. Araki T, Okada H, Onishi H. Does catheter shape influence the success of right adrenal venous sampling? The interaction of catheter shape to anatomical factors on CT. Jpn J Radiol. 2016
  5. 34(11):707-717. [CrossRef] 5. Lee BC, Chang CC, Liu KL, et al. Evaluation of right adrenal vein anatomy by dyna computed tomography in patients with primary aldosteronism. Sci Rep. 2016
  6. 6(1):1-8. [CrossRef] 6. Omura K, Ota H, Takahashi Y, et al. Anatomical variations of the right adrenal vein: concordance between multidetector computed tomography and catheter venography. Hypertension. 2017
  7. 69(3):428-434. [CrossRef] 7. Matsuura T, Takase K, Ota H, et al. Radiologic anatomy of the right adrenal vein: preliminary experience with MDCT. Am J Roentgenol. 2008
  8. 191(2):402-408. [CrossRef] 8. Rossi GP, Auchus RJ, Brown, et al. An expert consensus statement on use of adrenal vein sampling for the subtyping of primary aldosteronism. Hypertension. 2008
  9. 63(1):151-160. 9. Shibayama Y, Wada N, Naruse M, et al. The occurrence of apparent bilateral aldosterone suppression in adrenal vein sampling for primary aldosteronism. J Endocr Soc. 2018
  10. 2(5):398-407. [CrossRef] 10. DePietro DM, Fraker DL, Wachtel H, et al. Double-Down” Adrenal Vein Sampling Results in Patients with Apparent Bilateral Aldosterone Suppression: Utility of Repeat Sampling including Super-Selective Sampling. Journal of Vascular and Interventional Radiology. 2021