Journals / Cyprus Journal of Medical Sciences / 2021 / Cilt: 6 - Sayı: 4

Analysis of Peroperative Lateral Femoral Cortical Burst Complication Related to ToggleLoc with ZipLoop in Anterior Cruciate Ligament Reconstruction

Pages
279–284
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a precaution, condylar placement of the femoral tunnel lateral cortical aperture should be avoided.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:BACKGROUND/AIMS ToggleLoc adjustable loop suspension device is a widely used implant in anterior cruciate ligament (ACL) reconstruction, which offers several advantages.
📊
Key Findings & Data:RESULTS Peroperative lateral femoral cortical burst complication was observed in four of 52 patients.
💡
Conclusion & Impact:As a precaution, condylar placement of the femoral tunnel lateral cortical aperture should be avoided.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

BACKGROUND/AIMS ToggleLoc adjustable loop suspension device is a widely used implant in anterior cruciate ligament (ACL) reconstruction, which offers several advantages. However, peroperative problems related to these devices are not clear. The objective of this study was to report and analyze the peroperative lateral femoral cortical burst complication of ToggleLoc adjustable loop suspension device in ACL reconstruction. MATERIALS AND METHODS Fifty-two patients who underwent ACL reconstruction with ToggleLoc device were reviewed for peroperative lateral femoral cortical burst complication. The relation between lateral femoral cortical burst and tunnel position on lateral femoral cortex (condylar–- epicondylar) was investigated from patients’ records. A case-based analysis was done. Preoperative and postoperative Lysholm scores were also noted. RESULTS Peroperative lateral femoral cortical burst complication was observed in four of 52 patients. In five of the 52 cases, ToggleLoc button was placed over the condylar region, and four of the cases with condylar button placement had the complication. The mean preoperative and postoperative Lysholm scores were 37.98 (min: 26, max: 62) and 91.73 (min: 81, max: 100), respectively. CONCLUSION ToggleLoc button structure and distal loading of tensioning sutures cause increased risk of lateral femoral cortical burst during ACL reconstruction. As a precaution, condylar placement of the femoral tunnel lateral cortical aperture should be avoided.

🔖

Cite This Article

YALÇINOZAN, M., AYDIN, D. (2022). Analysis of Peroperative Lateral Femoral Cortical Burst Complication Related to ToggleLoc with ZipLoop in Anterior Cruciate Ligament Reconstruction. Cyprus Journal of Medical Sciences, Cilt: 6 - Sayı: 4, 279–284. https://ajindex.com/articles/482187

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Nye DD, Mitchell WR, Liu W, Ostrander RV. Biomechanical comparison of fixed-loop and adjustable-loop cortical suspensory devices for metaphyseal femoral-sided soft tissue graft fixation in anatomic anterior cruciate ligament reconstruction using a porcine model. Arthroscopy. 2017;33(6):1225-1232. [CrossRef] 2. Choi NH, Yang BS, Victoroff BN. Clinical and radiological outcomes after hamstring anterior cruciate ligament reconstructions: Comparison between fixed-loop and adjustable-loop cortical suspension devices. Am J Sports Med. 2017;45(4):826-831. [CrossRef] 3. Houck DA, Kraeutler MJ, McCarty EC, Bravman JT. Fixed-versus adjustable-loop femoral cortical suspension devices for anterior cruciate ligament reconstruction: A systematic review and metaanalysis of biomechanical studies. Orthop J Sports Med. 2018;6(10):2325967118801762. 4. Kubota M, Ohno R, Sato T, Yamada D, Fukusato S, Kaneko K. Pearls and pitfalls of the ToggleLoc with ZipLoop for anterior cruciate ligament reconstruction. Arthrosc Tech. 2018;7(8):e863-e867. [CrossRef] 5. Hammond KE, Dierckman BD, Potini VC, Xerogeanes JW, Labib SA, Hutton WC. Lateral femoral cortical breach during anterior cruciate ligament reconstruction: A biomechanical analysis. Arthroscopy. 2012;28(3):365-371. [CrossRef] 6. Petre BM, Smith SD, Jansson KS, et al. Femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction: A comparative biomechanical study. Am J Sports Med. 2013;41(2):416-422. [CrossRef] 7. Clockaerts S, Van Haver A, Verhaegen J, et al. Transportal femoral drilling creates more horizontal ACL graft orientation compared to transtibial drilling: A 3D CT imaging study. Knee. 2016;23(3):412-419. [CrossRef] 8. Zantop T, Haase AK, Fu FH, Petersen W. Potential risk of cartilage damage in double bundle ACL reconstruction: Impact of knee flexion angle and portal location on the femoral PL bundle tunnel. Arch Orthop Trauma Surg. 2008;128:509-513. [CrossRef]