Journals / Bitlis Eren Üniversitesi Fen Bilimleri Dergisi / 2019 / Cilt: 8 - Sayı: XII. International Conference on Nuclear Structure Properties (NSP 2019) Özel Sayı

The Determination of the Total Efficiency for NaI(Tl) Detector by GATE Simulation

NaI(Tl) Dedektörünün GATE Simülasyon Programıyla Toplam Veriminin Belirlenmesi

Pages
37–45
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The calculatedand simulated data indicated good agreement with finding more sensitive GATE simulation result in the lowerenergy range from 50 keV to 150 keV.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study the total efficiency of the NaI(Tl) detector have been calculated by using Geant4 based GATEsimulation program.
📊
Key Findings & Data:The simulation was performed using point and disc isotropic gamma-ray sources at variousdistance between source and detector in the photon energy range 50-3000 keV.
💡
Conclusion & Impact:The calculatedand simulated data indicated good agreement with finding more sensitive GATE simulation result in the lowerenergy range from 50 keV to 150 keV.
🔬Design:Research Article
📍Scope:2018 Verileri
⚙️Variables:Domain Parameters

Abstract

In this study the total efficiency of the NaI(Tl) detector have been calculated by using Geant4 based GATEsimulation program. The simulation was performed using point and disc isotropic gamma-ray sources at variousdistance between source and detector in the photon energy range 50-3000 keV. Results were compared withdifferent analytical and Monte Carlo calculations obtained in the time of the periods 1958-2018. The calculatedand simulated data indicated good agreement with finding more sensitive GATE simulation result in the lowerenergy range from 50 keV to 150 keV.

Özet

Bu çalışmada Geant4 tabanlı GATE simulasyon programı kullanılarak NaI(Tl) detektörünün toplam verimi hesaplanmıştır. Simulasyon, 50-3000 keV foton enerji aralığında çeşitli kaynak-detektör uzaklıklarında izotropik nokta ve disk gama ışını kaynağı kullanılarak gerçekleştirilmiştir. Sonuçlar, 1958-2018 periyodu boyunca elde edilen farklı analitik ve Monte Carlo hesaplamaları sonuçları ile karşılaştırılmıştır. Hesaplanan ve GATE simulasyonuyla elde edilen sonuçların birbiriyle uyumlu çıkmasının yanında, bu çalışmada 50 keV ile 150 keV arasındaki düşük enerjideki gamalar için çok daha hassas sonuçlar bulunmuştur.

🔖

Cite This Article

YALÇIN, S., YAVUZKANAT, N., GÜNGÜR, D. (2022). The Determination of the Total Efficiency for NaI(Tl) Detector by GATE Simulation. Bitlis Eren Üniversitesi Fen Bilimleri Dergisi, Cilt: 8 - Sayı: XII. International Conference on Nuclear Structure Properties (NSP 2019) Özel Sayı, 37–45. https://ajindex.com/articles/467032

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Zazubovich S. 2001. Physics of halide scintillators. Radiation Measurements, 33 (5): 699-704
  2. Mouhtia I., Elaniquea A., Messousb M.Y., Benahmedb A., McFeec J.E., Elgouba Y., Griffithd P. 2019. Characterization of CsI(Tl) and LYSO(Ce) scintillator detectors by measurements and Monte Carlo simulations. Applied Radiation and Isotopes, 154 (108878): 1-7
  3. Yalcin S., Gurler O., Kaynak G., Gundogdu O. 2007. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disc sources. Applied Radiation and Isotopes, 65: 1179-1186
  4. Tarım Akar U., Gürler O., Yalçın S. 2018. A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance. Celal Bayar University Journal of Science, 14 (2): 195-199
  5. Hofstadter R. 1949. The Detection of Gamma-Rays with Thallium-Activated Sodium Iodide Crystals. Physical Review, 75 (5): 796-810
  6. Pilakouta M., Pappa F.K., Patiris D.L., Tsabaris C., Kalfas C.A. 2018. A methodology for expanding the use of NaI(Tl) based spectrometry in environmental radioactivity measurements. Applied Radiation and Isotopes, 139: 159-168
  7. Zhang Y., Li C., Liu D., Zhang Y., Liu Y., 2015. Monte Carlo simulation of a NaI(Tl) detector for in situ radioactivity measurements in the marine environment. Applied Radiation and Isotopes, 98: 44-48
  8. Duc Tam H., Hai Yen N.T., Tran, L.B., Dinh Chuong, H., Thien Thanh, T. 2017. Optimization of the Monte Carlo simulation model of NaI(Tl) detector by Geant4 code. Applied Radiation and Isotopes, 130: 75–79
  9. Wang J., Zhang Y., Liu D., Wu B., Zhang Y., Jiang H., 2018. Automated spectra analysis of in situ radioactivity measurements in the marine environment using NaI(Tl) detector. Applied Radiation and Isotopes, 141: 88–94
  10. Hamzawy A., 2010. Simple analytical formula to calculate γ-ray cylindrical detectors efficiencies. Nuclear Instruments and Methods in Physics Research Section A, 624 (1): 124-129
  11. Chuong H.D., Nguyen Q.H., Nguyen T.M.L., Nguyen V.H. 2019. Validation of gamma scanning method for optimizing NaI(Tl) detector model in Monte Carlo simulation. Applied Radiation and Isotopes, 149: 1-8 [12] Zikovsky L., Chah B. 1988. A computer program for calculating Ge(li) detector counting efficiencies with large volume samples. Nuclear Instruments and Methods in Physics Research, A263 (2-3): 483-486
  12. Özmutlu C., Ortaovalı A.Z. 1976. Calculation of total and full energy peak efficienc