Test results indicate a significant enhancement in compressive strength, ductility and energy dissipation for the ex-ternally confined specimens for both low and medium strength concrete, with a more pronounced effect on low strength concrete.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The objective of this study is to evaluate the effects of unconfined concrete compressive strength and the thickness of the external jacket on the stress-strain behavior of fiber reinforced polymer (FRP) jacketed concrete specimens, particularly on the strength, ductility and energy dissipation characteristics.
📊
Key Findings & Data:In this experimental study, totally 16 concrete cylinder specimens are tested under axial compression.
💡
Conclusion & Impact:Test results indicate a significant enhancement in compressive strength, ductility and energy dissipation for the ex-ternally confined specimens for both low and medium strength concrete, with a more pronounced effect on low strength concrete.
🔬Design:Research Article
📍Scope:8 specimens
⚙️Variables:Domain Parameters

Abstract

The objective of this study is to evaluate the effects of unconfined concrete compressive strength and the thickness of the external jacket on the stress-strain behavior of fiber reinforced polymer (FRP) jacketed concrete specimens, particularly on the strength, ductility and energy dissipation characteristics. In this experimental study, totally 16 concrete cylinder specimens are tested under axial compression. The unconfmed concrete com-pressive strength for 8 specimens is around 30 MPa, while the remaining 8 specimens have the concrete compressive strength around 6 MPa. In each set, two unconfined specimens are tested without any strengthening, and other specimens are tested after they are externally confined by 1, 3 and 5 plies of FRP jackets in sets of two. Test results indicate a significant enhancement in compressive strength, ductility and energy dissipation for the ex-ternally confined specimens for both low and medium strength concrete, with a more pronounced effect on low strength concrete. Consequently, the investigated strengthening technique may be more preferable when dealing with structural members that have the problems of low compressive strength and ductility.

🔖

Cite This Article

KUMBASAR, N., KOÇ, V., İLKİ, A. (2022). Low and medium strength concrete members confined by fiber reinforced polymer jackets. ARI The Bulletin of the Istanbul Technical University, Cilt: 53 - Sayı: 1, 118–123. https://ajindex.com/articles/448166

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. A. Mirmiran and M. Shahawy, ASCE Journal of Structural Engineering 123, 583 (1997)
  2. V. M. Karbhari and Y. Gao, ASCE Journal of Materials in Civil Engineering 9, 185 (1997)
  3. H. A. Toutanji, ACI Materials Journal 96, 397, (1999)
  4. P; Rochette and P. Labossiere, ASCE Journal of Composites for Construction 4, 129 (2000)
  5. Y. Xiao and H. Wu, ASCE Journal of Materials in Civil Engineering 12, 139 (2000)
  6. A. İlki and N. Kumbasar, Int. Jour. Str. Eng. Mech. 13, 75 (2002)
  7. A. İlki, N. Kumbasar, and V. Koç, Strength and Deformability of Low Strength Concrete Confined by Carbon Fiber Composite Sheets, Proc. 15th ASCE Engineering Mechanics Conference, New York (2002).