Journals / Annals of Medical Research / 2022 / Cilt: 29 - Sayı: 2

Measuring optic nerve sheath diameter and lens thickness by b-mode sonographic evaluation in glaucoma

Pages
148–152
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: In glaucoma, sonography is a reliable tool of evaluating the optic nerve sheath diameter and lens thickness.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: This study was conducted to measure optic nerve sheath diameter (ONSD) and lens thickness (LT) with B-mode USG in patients with glaucoma and compare them with a healthy control group.
📊
Key Findings & Data:Materials and Methods: Seventy-two individuals were recruited, 35 with glaucoma and 37 age- and gender-matched controls without glaucoma.
💡
Conclusion & Impact:Conclusion: In glaucoma, sonography is a reliable tool of evaluating the optic nerve sheath diameter and lens thickness.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: This study was conducted to measure optic nerve sheath diameter (ONSD) and lens thickness (LT) with B-mode USG in patients with glaucoma and compare them with a healthy control group. Materials and Methods: Seventy-two individuals were recruited, 35 with glaucoma and 37 age- and gender-matched controls without glaucoma. Patients with systemic hypertension, diabetes mellitus, and cataract, history of ocular trauma, higher refractive error, active ophthalmologic infection and smoking were excluded from the study. The ONSD and LT values of both eyes were measured in the supine position using 10MHz frequency B-scan ultrasound. Data analysis was performed by transferring to the SPSS version 25 program. Results: The mean ONSD of glaucomatous eyes (3.60 mm and 3.50 mm on the right and left, respectively) was found to be significantly thinner than the controls (4.20 mm and 4.55 mm on the right and left, respectively). The mean LT of eyes with controls (4.25 mm and 4.15 mm on the right and left, respectively) was significantly lower compared to glaucoma (4.40 mm and 4.30 mm on the right and left, respectively). Conclusion: In glaucoma, sonography is a reliable tool of evaluating the optic nerve sheath diameter and lens thickness.

🔖

Cite This Article

DAĞDELEN, K. (2022). Measuring optic nerve sheath diameter and lens thickness by b-mode sonographic evaluation in glaucoma. Annals of Medical Research, Cilt: 29 - Sayı: 2, 148–152. https://ajindex.com/articles/445593

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Leffler CT, Schwartz SG, Giliberti FM, Young MT, Bermudez D. What was Glaucoma Called before the 20th Century? Ophthalmology and Eye Diseases. 2015;7:OED.S32004
  2. Sáles CS, Lee RY, Agadzi AK, Hee MR, Singh K, Lin SC. Open-angle glaucoma in Filipino and white Americans: a comparative study. Journal of glaucoma. 2014;23(4):246-53
  3. Tian H, Li L, Song F. Study on the deformations of the lamina cribrosa during glaucoma. Acta Biomaterialia. 2017;55:340-8
  4. Erb C. FunktionelleStörungenimzeitlichenVerlauf der Glaukomerkrankung. Der Ophthalmologe. 2015;112(5):402-9
  5. Okafor K, Vinod K, Gedde SJ. Update on pigment dispersion syndrome and pigmentary glaucoma. Current Opinion in Ophthalmology. 2017;28(2):154-60
  6. Miglior S, Bertuzzi F. Exfoliative glaucoma: new evidence in the pathogenesis and treatment. Progress in brain research. 221: Elsevier; 2015. p. 233-41
  7. Schuster AK, Erb C, Hoffmann EM, Dietlein T, Pfeiffer N. The Diagnosis and Treatment of Glaucoma. DeutschesÄrzteblatt International. 2020;117(13):225
  8. Omatiga AG, Onakpoya OH, Idowu BM, Asaleye CM, Adegbehingbe BO, Aderibigbe AS. B-mode sonographic evaluation of optic nerve sheath diameter and lens thickness in Nigerian adults with glaucoma. African Health Sciences. 2018;18(2):343-51
  9. Wang N, Xie X, Yang D, Ren R, Xian J, Li Y, et al. Evaluation of optic nerve and optic nerve sheath diameter in primary open angle glaucoma with 3-tesla magnetic resonance imaging. Investigative Ophthalmology & Visual Science. 2011;52(14):3963-
  10. Bourne RRA, Jonas JB, Bron AM, Cicinelli MV, Das A, Flaxman SR, et al. Prevalence and causes of vision loss in high-income countries and in Eastern and Central Europe in 2015: magnitude, temporal trends and projections. British Journal of Ophthalmology. 2018;102(5):575-85
  11. Bourne RRA, Taylor HR, Flaxman SR, Keeffe J, Leasher J, Naidoo K, et al. Number of People Blind or Visually Impaired by Glaucoma Worldwide and in World Regions 1990 – 2010: A Meta-Analysis. PLOS ONE. 2016;11(10):e0162229
  12. Beatty S, Good P, McLaughlin J, O’Neill E. Correlation between the orbital and intraocular portions of the optic nerve in glaucomatous and ocular hypertensive eyes. Eye. 1998;12(4):707-13
  13. Beatty S, Good P, McLaughlin J, O’Neill E. Echographic measurements of the retrobulbar optic nerve in normal and glaucomatous eyes. British journal of ophthalmology. 1998;82(1):43-7
  14. Liu H, Yang D, Ma T, Shi W, Zhu Q, Kang J, et al. Measurement and associations of the optic