Investigation of the thickness of surface reaction layer in titanium casting

Titanyum dökümlerde yüzey reaksiyon tabakası kalınlığının araştırılması

Pages
143–148
Publication Date
2022-10-10
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The minimum surface reaction layer was observed on the sample that had been casted by RTU.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Today, dental alloys, that have good physical properties, economic and corrosion resistant are preferred.
📊
Key Findings & Data:The value of surface reaction layer on titanium samples casted by RTF and RTU on A, B, C surfaces showed significant differences (P < 0.001).
💡
Conclusion & Impact:The minimum surface reaction layer was observed on the sample that had been casted by RTU.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Today, dental alloys, that have good physical properties, economic and corrosion resistant are preferred. Titanium and titanium alloys called nobel alloys, are commonly used. Not only the difficulty of casting of titanium, but also the surface reaction layer that presents on the surface and the thickness of this layer are important. In this study, the thickness of surface reaction layer in titanium cast was searched by using two kinds of investment. The surface reaction layer of titanium samples casted by two different kinds of investment, rematitan plus (RTF) and rematitan ultra (RTU) were determined by computerised optic microscope. The value of surface reaction layer on titanium samples casted by RTF and RTU on A, B, C surfaces showed significant differences (P < 0.001). By decreasing the volume of casting sample, the amount of titanium that has contaminated was decreased. The minimum surface reaction layer was observed on the sample that had been casted by RTU.

Özet

Günümüzde fiziksel özellikleri iyi, korozyona dirençli, ekonomik olan dental alaşımlar tercih edilmeye başlanmıştır. Kıymetsiz metal grupları içinde yer alan titanyum ve titanyum alaşımları kullanımı giderek yaygınlaşmaktadır. Titanyum dökümündeki zorluğun yanında yüzeyinde oluşan yüzey reaksiyon tabakası ve bu tabakanın kalınlığıda önemlidir. Bu araştırmada farklı iki rövetman kullanılarak elde edilen titanyum dökümlerde yüzey reaksiyon tabakasının kalınlığının araştırılması amaçlanmıştır. İçeriği farklı iki rövetman rematitan plus (RTF) ve rematitan ultra (RTU) rövetmanlarla dökülmüş titanyum örneklerde yüzey reaksiyon tabakası bilgisayar destekli optik mikroskopla değerlendirildi. RTF ve RTU ile dökülen örneklerden alınan yüzey reaksiyon kalınlığı değerleri A, B, C yüzeylerinde birbirinden anlamlı derecede farklıdır (P < 0.001). Dökülen objenin hacmi azaldıkça kontaminasyona uğrayan metal miktarı azaldığı için yüzey reaksiyon tabakası kalınlığı azaldı. Yüzey reaksiyon tabakası kalınlığı en düşük RTU ile dökülen örneklerde elde edildi.

🔖

Cite This Article

MANAV, Ö., YAZICIOĞLU, H. (2022). Investigation of the thickness of surface reaction layer in titanium casting. Ankara Üniversitesi Diş Hekimliği Fakültesi Dergisi, Cilt: 29 - Sayı: 2, 143–148. https://ajindex.com/articles/442287

References (18)

  1. Ersoy E. Sabit protez alaşımları. A Ü Diş Hek Fak Der 1989; 16: 539-42
  2. PâBler K. Titan in der Zahnmedizin in "Titan in der Zahnmedezin" (Wirz J, Bischoff H ed) Quintessenz Verlags-GmbH Berlin 1997; 1:41- 62
  3. PâBler K. Der Dental Titangub-Grundlagen Technologie und Werkstoffkundliche Bewentung. Quintessenz Zahntech 1991; 18: 717-26
  4. PaBler K, Bestelmeyer F, Ohmmacht P, Sernet F. Einfliisse auf die qualitat und eigenschaften von dentalen titangüssen. Denta Labour 1991;39: 809-15
  5. Lautenschlager EP, Monaghan P. Titanium and titanium alloys as dental materials. Int Dental J 1993;43: 245-53
  6. Weber H, Pröbster L, Geis-Gerstorfer J. Titan als Prothetischer Werkstoff. Dtsch Zahnarztl Z 1992;2: 473-81
  7. Hopp M, Lange KP. TitanguB in "Titan in der Zahnmedizin" (Wirz J. Bischoff H ed.) Quintessenz Verlags-GmbH Berlin 1997;3:71- 86
  8. Myakawa O, Watonabe K, Okava S, Nakano S, Kobayashi M, Shiokawa N. Layered Structure of cast titanium surface. Dent Mater J 1989;8: 175-85
  9. Matthew J, Donachie J. Titanium. 1st ed ASM International Metals Park USA 1988;31-9
  10. Brauner H. Zur Randschichtaufhartung an titan werkstaffen durch unterschiedliche forms toffe und Einhettmassen. Dtsch Zahnarztl Z 1992;2: 511-5
  11. Pâsler K. Darstellung, priifung und eigen- schaften von edelmetallfreien dentallegierungen und titan. 1st ed Quintessenz Verlags-GmbH Berlin 1998;76-9
  12. Luthy H. Titanium. Materials Science Aspects 1st information meeting on titanium in dentistry. Geneva Conference Abtracts 1994;31- 45
  13. Yılmaz H. Titanyum ve protetik diş tedavisinde kullanımı. AÜ Diş Hek Fak Der 1998;8: 75-9
  14. Meyer JM. Titanium: Today and tomorrow. Ist information meeting on titanium in dentistry. Geneva Conference Abstracts 1994;9- 20
  15. Lenz E. Die randschicten von titanguBobjekten in "titan in der Zahnmedizin" (Wirz J. Bischoff H ed) Quintessenz Verlags-GmbH Berlin 1997;3:106-14
  16. Geis-Gerstorfer J, Simonis A, Eckhardt M, Hoselberger D. Der titanguB mit dem titaniumer die guBtechinc. 1st noch nicht vol ausgereift. Dental Labor 1989;37: 1789-92
  17. Pasler K, Bestelmeyer F, Ohnmacht P, Sernet F. Einflusse auf die gualitat und eigenschaften von dentalen titangussen. Dental Labor 1991;39: 809-15
  18. International Standard. Metalic and Oxid Coatings-measurement of coating thickness- microcopical method. 2nd ed 1463 ISO Switzerland 1982. 19*. Takahashi J, Kimura H, Lautenschlager EP, Chern UH, Moser JB, Greener EH. Casting pure titanium into commercial phospha