Journals / Anadolu Üniversitesi Bilim ve Teknoloji Dergisi :A-Uygulamalı Bilimler ve Mühendislik / 2017 / Cilt: 18 - Sayı: 1

COMPARISON OF THE MECHANICAL RESPONSE OF POROUS Ti-6Al-4V ALLOYS PRODUCED BY DIFFERENT COMPACTION TECHNIQUES

Pages
13–21
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

However, the S-DP foam, which was produced by diepressing of spherical powders, has the highest toughness.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Porous Ti-6Al-4V alloys are attractive candidates as implant materials due to their good biocompatibility combined with the porous structure leading to increased osseointegration and decreased stiffness.
📊
Key Findings & Data:Accordingly, different processing techniques were employed for the production of Ti-6Al-4V foams in the literature.
💡
Conclusion & Impact:However, the S-DP foam, which was produced by diepressing of spherical powders, has the highest toughness.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Porous Ti-6Al-4V alloys are attractive candidates as implant materials due to their good biocompatibility combined with the porous structure leading to increased osseointegration and decreased stiffness. Accordingly, different processing techniques were employed for the production of Ti-6Al-4V foams in the literature. Among these techniques, sintering with space holder is used to produce porous Ti-6Al-4V alloys in this study. Magnesium was employed as the space holder material because of its relatively low boiling point as well as high oxygen affinity. Two different compaction techniques, die compaction with hydraulic pressing and cold isostatic pressing (CIP), were employed for obtaining green compacts. Both spherical and nonspherical Ti-6Al-4V powders were used to investigate the effect of powder shape on compaction. Processed foams were characterized in terms of both microstructural and mechanical aspects in order to investigate the effect of pressing conditions in combination with powder characteristics. It was observed that NS-CIP foam, which was produced by compacting nonspherical powders by cold isostatic press, has the highest strength. However, the S-DP foam, which was produced by diepressing of spherical powders, has the highest toughness.

🔖

Cite This Article

AŞIK, E. E., SELİMOĞLU, G. İ., ŞEN, F., YAYMACI, G. (2022). COMPARISON OF THE MECHANICAL RESPONSE OF POROUS Ti-6Al-4V ALLOYS PRODUCED BY DIFFERENT COMPACTION TECHNIQUES. Anadolu Üniversitesi Bilim ve Teknoloji Dergisi :A-Uygulamalı Bilimler ve Mühendislik, Cilt: 18 - Sayı: 1, 13–21. https://ajindex.com/articles/438276

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Hartman AD, Gerdemann SJ, Hansen JS. Producing lower-cost titanium for automotive applications J. Min. Metals Mater. Soc., 50:16-19, 1998
  2. Boyer RR. An overview on the use of titanium in the aerospace industry Mater. Sci. Eng. A, 213:103-114, 1996
  3. Geetha M, Singh AK, Asokamani R, Gogia AK Ti based biomaterials, the ultimate choice for orthopaedic implants - A review Prog. Mater. Sci., 54:397-425, 2009
  4. Rack HJ, Qazi JI. Titanium alloys for biomedical applications Mater. Sci. Eng. C, 26:1269-1277, 2006
  5. Niinomi M. Mechanical properties of biomedical titanium alloys Mater. Sci. Eng. A, 243:231-236, 1998
  6. Spoerke ED, Murray NG, Li H, Brinson LC, Dunand DC, Stupp SI. A bioactive titanium foam scaffold for bone repair Acta Biomater. 1:523-33, 2005
  7. Heinl P, Müller L, Körner C, Singer RF, Müller FA. Cellular Ti-6Al-4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting Acta Biomater., 4:1536-44, 2008
  8. Navarro M, Michiardi A, Castaño O, Planell JA. Biomaterials in orthopaedics J. R. Soc. Interface, 5:1137-58, 2008
  9. Jacobs JJ, Sumner DR, Galante JO. Mechanisms of bone loss associated with total hip replacement Orthop. Clin. North Am., 24:583-90, 1993
  10. Karachalios T, Tsatsaronis C, Efraimis G, Papadelis P, Lyritis G, Diakoumopoulos G. The longterm clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty J. Arthroplasty, 19:469-475, 2004
  11. Arpak B, Araz K, Nakaş İ, Bor Ş, Nergiz İ. The mechanical characterization and in vivo evaluation of porous tini as graft material Funct. Mater. Lett., 05:1250023, 2012
  12. Willie BM, Yang X, Kelly NH, Merkow J, Gagne S, Ware R, Wright TM, Bostrom MP. Osseointegration into a novel titanium foam implant in the distal femur of a rabbit J. Biomed. Mater. Res. B. Appl. Biomater., 92:479-488, 2010
  13. Kienapfel H, Sprey C, Wilke A, Griss P. Implant fixation by bone ingrowth J. Arthroplasty, 14:355-368, 1999
  14. Banhart J. Manufacture, characterisation and application of cellular metals and metal foams Prog. Mater. Sci., 46:559-632, 2001
  15. Clemow AJ, Weinstein AM, Klawitter JJ, Koeneman J, Anderson J. Interface mechanics of porous titanium implants J. Biomed. Mater. Res., 15:73-82, 1981
  16. Esen Z, Bor Ş. Processing of titanium foams using magnesium spacer particles. Scr. Mater., 56:341-344, 2007
  17. Nilles JL, Lapitsky M. Biomechanical investigations of bone-porous carbon and porous meta