⚡ TL;DR(Too Long; Didn't Read)

Electricity consumption and payback period were also determined by considering the various parameters of the study.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Energy savings on cooling systems can be achieved using novel refrigeration cycles.
📊
Key Findings & Data:While lithium bromide-water and NH3/H2O are the working fluids in the vapor-absorption part, various refrigerants are used in the vapor-compression section.
💡
Conclusion & Impact:Electricity consumption and payback period were also determined by considering the various parameters of the study.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Energy savings on cooling systems can be achieved using novel refrigeration cycles. To this end, vapor-compression/vaporabsorption cascade refrigeration systems may be a substitute for single-stage vapor-compression refrigeration systems. These cycles can use renewable energy sources such as geothermal and solar heat energy as well as waste heat from processes to provide cooling, and they also require less electrical energy than vapor-compression cycles with alternative refrigerants. In this study, vapor-compression and vapor-absorption cascade systems undergo second-law analysis for various cooling capacities. While lithium bromide-water and NH3/H2O are the working fluids in the vapor-absorption part, various refrigerants are used in the vapor-compression section. The refrigerants R134a and R600a as well as R410A and R407C are tested in the study. The effects on the coefficient of system performance (COP) of alterations in cooling capacity, superheating, and subcooling in the vapor-compression part; temperature in the generator and absorber; and degree of overlap in cascade condenser in the vaporabsorption part. The results were validated by values given in the literature. Improvements in the COPs of the vapor compression, vapor absorption, and cascade systems were obtained separately. According to the analyses, cascade systems' COP increases with generator and evaporator temperatures and also increase as condenser and absorber temperatures decrease. Moreover, the generator had the highest exergy-destruction rates, followed by the condenser and absorber, respectively. Electricity consumption and payback period were also determined by considering the various parameters of the study.

🔖

Cite This Article

TANER, T., WONGWISES, S., DALKILIÇ, A. S., ÇELEN, A., ÇEBİ, A. (2022). PARAMETRIC STUDY OF ENERGY, EXERGY AND THERMOECONOMIC ANALYSES ON A VAPOR-COMPRESSION SYSTEM CASCADED WITH LIBR/WATER AND NH3/WATER ABSORPTION CASCADE REFRIGERATION CYCLES. Anadolu Üniversitesi Bilim ve Teknoloji Dergisi :A-Uygulamalı Bilimler ve Mühendislik, Cilt: 18 - Sayı: 1, 78–96. https://ajindex.com/articles/438262

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Cimsit C, Ozturk IT. Buhar sıkıştırmalı-absorbsiyonlu çift kademeli soğutma çevrimi ve alternatif çevrimlerle karşılaştırılması. Isı Bilim Tek Derg 2014; 34(1): 19-26
  2. Solum C, Heperkan H. Jeotermal enerjili çift etkili lityum bromür - su akışkanlı absorbsiyonlu soğutma sisteminin ekserji analizi. Tesis Müh 2015; 147: 27-34
  3. Bouaziz N, Benlffa R, Nehdi E, Kairouani L. Conception of an absorption refrigerating system operating at low enthalpy sources. Thermodynamics- Systems in Equilibrium and Nonequilibrium, InTech, 2011
  4. Cimsit C, Ozturk IT, Hosoz M. Second law based thermodynamic analysis of compressionabsorption cascade refrigeration cycles. Isı Bilim Tek Derg 2014; 34(2): 9-18
  5. Yakar G, Karabacak R, Altan B D. Absorpsiyonlu soğutma sistemleri ile mekanik sıkıştırmalı soğutma sistemlerinin etkinlik ve ekserji verimlilikleri yönünden karşılaştırılmaları. Pamuk Üni Müh Fak Derg 2005; 11(2): 161-169
  6. Kaynaklı Ö, Yamankaradeniz R. Absorpsiyonlu soğutma sistemlerinde kullanilan eşanjörlerin sistemin performansina etkisi. Ulu Üni Müh Fak Derg 2003; 1: 111-120
  7. Öcal P, Pıhtılı K. Kademeli soğutma sistemlerinde belirli soğutucu akışkanlar için ikinci kanun analizi. In: 2. Ulusal İklimlendirme Soğutma Eğitimi Sempozyumu ve Sergisi; 23-25 October 2014; Balıkesir, Turkey: pp. 23-25
  8. Selbas R. Absorbsiyonlu soğutma sistemlerinde absorber sıcaklığının etkisinin termodinamik ve termoekonomik analizi. Süley Demir Üni Fen Bilim Enst Derg 2006; 10-1: 136-143
  9. Seewald JS, Perez-Blanco H. A simple model for calculating the performance of a lithiumbromide/water coil absorber. Ashrae Transactions 1993; 100(2)-3814: 3814-3824
  10. Solum C, Koç İ, Altuntaş Y. Çift etkili LiBr/H2O akışkanlı absorpsiyonlu soğutma sisteminde termodinamiksel büyüklüklerin sistem performansina etkileri. Hav Uzay Tekn Derg 2011; January 1(5): 19-26
  11. Yakut AK, Şencan Ş, Selbaş A, Dikmen R, Görgülü E, Dostuçok Bİ, Kutlu S. Güneş enerjisi destekli absorbsiyonlu soğutma sisteminin termodinamik incelemesi. İKLİM 2011 Ulusal İklimlendirme Kongresi; 18-20 December 2011, Antalya, Turkey: pp. 51-60
  12. Jain V, Kachhwaha SS, Sachdeva G. NLP model based thermoeconomic optimization of vapor compression-absorption cascaded refrigeration system. Energ Convers Manage 2014; 93: 49-62
  13. Jain V, Kachhwaha SS, Sachdeva G. Thermodynamic performance analysis of a vapor compression-absorption cascaded refrigeration system. Energ Convers Manage 2013; 75: 685-700
  14. Karak