Journals / Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi / 2017 / Cilt: 23 - Sayı: 5

Extending PROFIBUS segments through IEEE 802.11 wireless LAN

IEEE 802.11 kablosuz LAN kullanarak PROFIBUS segmentlerin genişletilmesi

Pages
573–580
Publication Date
2017-10-20
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Performance evaluation of the Wireless Interworking Unit is carried out according to utilization of PROFIBUS segments, end-to-end message delay of independent PROFIBUS segments (remote) messages and WIU process time parameters.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:PROFIBUS is defined with international standards is a fieldbus standard with widespread usage in industrial process control applications.
📊
Key Findings & Data:To overcome these requirements the best solution is to utilize wireless network technologies due to advantages such as high data rates, cost and mobility etc.
💡
Conclusion & Impact:Performance evaluation of the Wireless Interworking Unit is carried out according to utilization of PROFIBUS segments, end-to-end message delay of independent PROFIBUS segments (remote) messages and WIU process time parameters.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:PROFIBUS · IEEE 802.11g WLAN · Kablosuz arabağlaşım

Abstract

PROFIBUS is defined with international standards is a fieldbus standard with widespread usage in industrial process control applications. PROFIBUS as other Fieldbus systems has two main requirements such as extending independent PROFIBUS segments and communicating with other LANs. To overcome these requirements the best solution is to utilize wireless network technologies due to advantages such as high data rates, cost and mobility etc. In this research work, the designed PROFIBUS/IEEE 802.11g WLAN Wireless Interworking Unit (WIU) is presented to extend PROFIBUS segment through IEEE 802.11 g WLAN. Modeling and computer simulation of the designed WIU are performed using discrete-event simulation technique. Performance evaluation of the Wireless Interworking Unit is carried out according to utilization of PROFIBUS segments, end-to-end message delay of independent PROFIBUS segments (remote) messages and WIU process time parameters.

Özet

PROFIBUS uluslararası standartlar ile tanımlanmış endüstriyel süreç kontrol uygulamalarında yaygın kullanıma sahip bir saha veri yoludur. Diğer saha veri yolu sistemleri gibi PROFIBUS sistemlerin de bağımsız saha veri yolu segmentlerini genişletmek ve diğer ağlar ile haberleşmek olmak üzere iki temel gereksinimi vardır. Bu gereksinimleri karşılamak için en iyi çözüm yüksek veri iletim hızları, maliyet ve hareketlilik gibi avantajları ile kablosuz ağ teknolojilerinden yararlanmaktır. Bu araştırma çalışmasında PROFIBUS segmentleri IEEE 802.11g WLAN aracılığıyla genişletmek için tasarlanan PROFIBUS/IEEE 802.11g WLAN Kablosuz Arabağlaşım Birimi (KAB) sunulmaktadır. Tasarlanan PROFIBUS/IEEE 802.11g WLAN KAB’ın modellemesi ve bilgisayarlı benzetimi ayrık olay simülasyon tekniği ile gerçekleştirilmiştir. Kablosuz Arabağlaşım Biriminin başarım analizi, PROFIBUS saha veri yolunun kullanım oranı, bağımsız PROFIBUS segmentlerin (uzak) mesajlarının uçtan-uca gecikme ve KAB’ın işlem zamanı parametrelerine göre gerçekleştirilmiştir.

🔖

Cite This Article

Bayılmış, C., Özçelik, İ. (2017). Extending PROFIBUS segments through IEEE 802.11 wireless LAN. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, Cilt: 23 - Sayı: 5, 573–580. https://ajindex.com/articles/42495

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Thomesse JP. “Fieldbus technology in industrial automation”. Proceedings of the IEEE, 93(6), 1073-1101, 2005.
  2. Ozcelik I, Ekiz H. “Design, implementation and performance analysis of the PROFIBUS/ATM Local Bridge”. Computer Standards & Interface, 26(4), 329-342, 2004.
  3. Bayilmis C, Erturk I, Ceken C, Ozcelik I. “A CAN/IEEE 802.11b wireless lan local bridge design”. Computer Standards & Interface, 30(3), 200-212, 2008.
  4. Cavalieri S, Pano D. “A novel solution to interconnect FieldBus systems using IEEE wireless LAN technology”. Computer Standards & Interface, 20(1), 9-23, 1998.
  5. Erturk I. “A new method for transferring CAN messages using wireless ATM”. Journal of Network and Computer Applications, 28(3), 45-56, 2005.
  6. Ozcelik I. “Interconnection of CAN segments through IEEE 802.16 wireless MAN”. Journal of Network and Computer Applications, 31 (4), 879-890, 2008.
  7. Koulamas C, Koubias G, Papadopulos G. “Using cut-through forwarding to retain the real-time properties of profibus over hybrid wired/wireless architectures”. IEEE Transactions on Industrial Electronics, 51(6), 1208-1217, 2004. Alves F. Real-Time Communications Over Hybrid Wired/Wireless PROFIBUS-Based Networks. Phd Thesis, Porto University, Porto, Portogual, 2003.
  8. Sousa PB, Ferreira LL. “Hybrid Wired/Wireless PROFIBUS architectures: Performance study based on simulation models”. EURASIP Journal on Wireless Communications and Networking, 2010 (1), 1-25, 2010.
  9. Kjellsson J, Vallestad AE, Steigmann R, Dzung D. “Integration of a wireless I/O interface for PROFIBUS and PROFINET for factory automation”. IEEE Transaction on Industrial Electronics, 56(10), 4279-4287, 2009.
  10. Zhong L, Liu S, Zhang X, Liang W, Zhou Y. “Interconnection technique between wireless factory automation network and PROFIBUS-DP”. 11th World Congress on Intelligent Control and Automation, Shenyang, China, 29 June - 4 July 2014.
  11. Pellegrini F, Miorandi D, Vitturi S, Zanella A. “On the use of wireless networks at low level of factory automation systems”. IEEE Transactions on Industrial Informatics, 2 (2), 129-143, 2006.
  12. Willig A, Matheus K., Wolisz A. “Wireless technology in industrial networks”. Proceedings of the IEEE, 93(6), 1130-1151, 2005. International Electrotechnical Commission. “PROFIBUS Specification”. Switzerland, IEC 61158, 2000.
  13. PROFIBUS Nutzerorganisation.“PROFIBUS Brochure: PROFIBUS Technology and Application”. Karlsruhe, Germany, 4.002, 2002.
  14. Vassis D, Kormentzas A, Rouskas A, Maglogiannis I. “The IEEE 802.11g standard for high dat