Journals / Türk Göğüs Kalp Damar Cerrahisi Dergisi / 2013 / Cilt: 21 - Sayı: 3

Transcatheter closure of antegrade pulmonary blood flow in a case withpersistent pulmonary effusion following cavopulmonary anastomosis

Kavopulmoner anastomoz sonrası persistan plevral efüzyon gelişen bir olguda antegrad pulmoner kan akımın transkateter yolla kapatılması

Pages
746–749
Publication Date
2022-09-02
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The mean pulmonary arterial pressure was decreased to an acceptable level (17 mmHg) for Glenn anastomosis, by transcatheter occlusion of antegrade pulmonary blood flow using a Cardio-Fix Duct occluder.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Preserving antegrade pulmonary blood flow in patients who are candidates for univentricular repair and receive palliation by the Glenn anastomosis is still controversial.
📊
Key Findings & Data:Cardiac catheterization performed for repetitive pleural effusions and superior vena cava syndrome revealed that the mean pulmonary artery pressure was quite elevated (27 mmHg) for Glenn anastomosis.
💡
Conclusion & Impact:The mean pulmonary arterial pressure was decreased to an acceptable level (17 mmHg) for Glenn anastomosis, by transcatheter occlusion of antegrade pulmonary blood flow using a Cardio-Fix Duct occluder.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Preserving antegrade pulmonary blood flow in patients who are candidates for univentricular repair and receive palliation by the Glenn anastomosis is still controversial. In this article, a three-year-old girl underwent cavopulmonary anastomosis with preserved antegrade pulmonary blood flow. Cardiac catheterization performed for repetitive pleural effusions and superior vena cava syndrome revealed that the mean pulmonary artery pressure was quite elevated (27 mmHg) for Glenn anastomosis. The mean pulmonary arterial pressure was decreased to an acceptable level (17 mmHg) for Glenn anastomosis, by transcatheter occlusion of antegrade pulmonary blood flow using a Cardio-Fix Duct occluder. Key words:

Özet

Glenn anastomozu gerçekleştirilerek palyasyon sağlanan üniventriküler tamir adayı hastalarda, antegrad pulmoner kan akımının korunması halen tartışmalıdır. Bu yazıda, üç yaşındaki kız çocuğunda antegrad pulmoner kan akımı korunarak, kavopulmoner anastomoz gerçekleştirildi. Tekrarlayan plevral efüzyon ve vena kava superior sendromu için yapılan kalp kateterizasyonunda, pulmoner arter ortalama basıncının (27 mmHg) Glenn anastomozu için oldukça yüksek olduğu izlendi. Antegrad pulmoner kan akımı transkateter yoldan Cardio-Fix Dukt okluder ile kapatıldıktan sonra, pulmoner arter ortalama basıncının (17 mmHg) Glenn anastomozu için kabul edilebilir düzeye inmesi sağlandı.

🔖

Cite This Article

YÜCEL, İ., ÇELEBİ, A., AYDEMİR, N. A., ERDEM, A., DEMİR, H. (2022). Transcatheter closure of antegrade pulmonary blood flow in a case withpersistent pulmonary effusion following cavopulmonary anastomosis. Türk Göğüs Kalp Damar Cerrahisi Dergisi, Cilt: 21 - Sayı: 3, 746–749. https://ajindex.com/articles/424543

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Kopf GS, Laks H, Stansel HC, Hellenbrand WE, Kleinman CS, Talner NS. Thirty-year follow-up of superior vena cava- pulmonary artery (Glenn) shunts. Thorac Cardiovasc Surg 1990;100:662-70
  2. Pridjian AK, Mendelsohn AM, Lupinetti FM, Beekman RH 3rd, Dick M 2nd, Serwer G, et al. Usefulness of the bidirectional Glenn procedure as staged reconstruction for the functional single ventricle. Am J Cardiol 1993;71:959-62
  3. Uemura H, Yagihara T, Kawashima Y, Okada K, Kamiya T, Anderson RH. Use of the bidirectional Glenn procedure in the presence of forward flow from the ventricles to the pulmonary arteries. Circulation 1995;92:II228-32
  4. Miyaji K, Shimada M, Sekiguchi A, Ishizawa A, Isoda T. Usefulness of pulsatile bidirectional cavopulmonary shunt in high-risk Fontan patients. Ann Thorac Surg 1996;61:845-50
  5. Frommelt MA, Frommelt PC, Berger S, Pelech AN, Lewis DA, Tweddell JS, et al. Does an additional source of pulmonary blood flow alter outcome after a bidirectional cavopulmonary shunt? Circulation 1995;92:II240-4
  6. Mainwaring RD, Lamberti JJ, Uzark K, Spicer RL, Cocalis MW, Moore JW. Effect of accessory pulmonary blood flow on survival after the bidirectional Glenn procedure. Circulation 1999;100:II151-6
  7. Gray RG, Altmann K, Mosca RS, Prakash A, Williams IA, Quaegebeur JM, et al. Persistent antegrade pulmonary blood flow post-glenn does not alter early post-Fontan outcomes in single-ventricle patients. Ann Thorac Surg 2007;84:888-93
  8. Ebeid MR, Gaymes CH, Joransen JA. Catheter closure of accessory pulmonary blood flow after bidirectional Glenn anastomosis using Amplatzer duct occluder. Catheter Cardiovasc Interv 2002;57:95-7
  9. Torres A, Gray R, Pass RH. Transcatheter occlusion of antegrade pulmonary flow in children after cavopulmonary anastomosis. Catheter Cardiovasc Interv 2008;72:988-93. doi: 10.1002/ccd.21748
  10. Petko C, Gray RG, Cowley CG. Amplatzer occlusion of accessory ventriculopulmonary connections. Catheter Cardiovasc Interv 2009;73:105-8. doi: 10.1002/ccd.21831
  11. Desai T, Wright J, Dhillon R, Stumper O. Transcatheter closure of ventriculopulmonary artery communications in staged Fontan procedures. Heart 2007;93:510-3.