Journals / Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi / 2017 / Cilt: 23 - Sayı: 7

Glassy carbon modified with triazol derivative for analysis of cadmium (II)

Kadmiyum (II) analizi için triazol türevi modifiye edilmiş camsı karbon

Pages
874–876
Publication Date
2017-12-27
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The concentration range and the detection limit were 1.0×10-9-1.0×10-8 M and 2.0×10-10 M, respectively.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Cadmium is recently threatening not only the life of man but also nature and living environment.
📊
Key Findings & Data:In addition, cadmium usage is generally decreasing because it is toxic. 3-Methyl-4-(4-hydroxybenzylidenamino)-4,5-dihydro-1H-1,2,4-triazol-5-one (MDT) in 0.1 M supporting electrolyte was attached to glassy carbon electrode (GCE) by the phenol oxidation.
💡
Conclusion & Impact:The concentration range and the detection limit were 1.0×10-9-1.0×10-8 M and 2.0×10-10 M, respectively.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:MDT · Oksidasyon · Kadmiyum (II) iyon analizi

Abstract

Cadmium is recently threatening not only the life of man but also nature and living environment. In addition, cadmium usage is generally decreasing because it is toxic. 3-Methyl-4-(4-hydroxybenzylidenamino)-4,5-dihydro-1H-1,2,4-triazol-5-one (MDT) in 0.1 M supporting electrolyte was attached to glassy carbon electrode (GCE) by the phenol oxidation. The modified surface was investigated by several methods. The stability of the prepared surface was presented. The GCE with MDT was utilized for Cd(II) ions analysis in water samples. The concentration range and the detection limit were 1.0×10-9-1.0×10-8 M and 2.0×10-10 M, respectively.

Özet

Camsı karbon elektrot (GCE), 3-Methyl-4-(4-hydroxybenzylidenamino)-4,5-dihydro-1H-1,2,4-triazol-5-one (MDT)’ nin fenol oksidasyonu ile 0.1 M destek elektrolit içinde modifiye olmuştur. Modifiye edilmiş yüzey, birkaç teknik kullanılarak ile karakterize edilmiştir. Hazırlanan yüzeyin kararlılığı gösterilmiştir. MDT ile modifye edilmiş GCE, su örneklerinde Cd(II) iyon analizi için kullanılmıştır. Derişim aralığı ve deteksiyon limiti sırasıyla 1.0×10-9 - 1.0×10-8 M ve 2.0×10-10 M, olarak bulunmuştur.Kadmiyum son yıllarda sadece insan yaşamını değil doğa ve yaşam alanını da tehdit etmektedir. Ayrıca, toksik olmasından dolayı kadmiyum kullanımı genellikle azalmaktadır.

🔖

Cite This Article

YÜKSEK, H., ALKAN, M., BAHÇECİ, Ş., AKYILDIRIM, O., BEYTUR, M., YOLA, M. L. (2017). Glassy carbon modified with triazol derivative for analysis of cadmium (II). Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, Cilt: 23 - Sayı: 7, 874–876. https://ajindex.com/articles/42449

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Oztekin Y, Tok M, Nalvuran H, Kiyak S, Gover T, Yazicigil Z, Ramanaviciene A, Ramanavicius A. “Electrochemical modification of glassy carbon electrode by poly-4-nitroaniline and its application for determination of copper (II)”. Electrochimica Acta, 56(1), 387-395, 2010.
  2. Oztekin Y, Krikstolaityte V, Ramanaviciene A, Yazicigil Z, Ramanavicius A. “1,10-Phenanthroline derivatives as mediators for glucose oxidase”. Biosensors and Bioelectronics, 26(1),267-270, 2010.
  3. Goyal RN, Oyama M, Gupta VK, Singh SP, Sharma RA. “Sensors for 5-hydroxytryptamine and 5-hydroxyindole acetic acid based on nanomaterial modified electrodes”. Sensors and Actuators B: Chemical, 134(1), 816-821, 2008.
  4. Deinhammer RS, Ho M, Anderegg JW, Porter MD. “Electrochemical oxidation of amine-containing compounds: a route to the surface modification of glassy carbon electrodes”. Langmuir, 10(1), 1306-1313, 1994.
  5. Downard AJ, Tan ESQ, Yu SSC. “Controlled assembly of gold nanoparticles on carbon surfaces”. New Journal of Chemistry, 30(1), 1283-1288, 2006.
  6. Sullivan MG, Schnyder B, Bartsch M, Alliata D, Barbero C, Imhof R, Kotz R. “Electrochemically modified glassy carbon for capacitor electrodes characterization of thick anodic layers by cyclic voltammetry, differential electrochemical mass spectrometry, spectroscopic ellipsometry, X-ray photoelectron spectroscopy, FTIR and AFM”. Journal of the Electrochemical Society, 147(2), 2636-2643, 2000.
  7. Tsierkezos NG, Ritter U. “Application of electrochemical impedance spectroscopy for characterisation of the reduction of benzophenone in acetonitrile solutions” Physics and Chemistry of Liquids, 49(2), 729-742, 2011.
  8. Liao HC, Jiang SJ. “Determination of cadmium, mercury and lead in coal fly ash by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry”. Spectrochimica Acta Part B: Atomic Spectroscopy, 54(1), 1233-1242, 1999.
  9. Bortoleto GG, Macarovscha GT, Cadore S. “Determination of cadmium by flame-atomic absorption Spectrometry after preconcentration on silica gel modified with cupferron”. Journal Brazilian Chemical. Society, 15(2), 313-317, 2004.
  10. Mhammedi MAE, Achak M, Hbid M, Bakasse M, Hbid T, Chtaini A. “Electrochemical determination of cadmium(II) at platinum electrode modified with kaolin by square wave voltammetry”. Journal of Hazardous Materials, 170(1), 590-594, 2009.
  11. Liu M, Feng Y, Wang G, Fang B. “Determination of cadmium(II) using glassy carbon electrodes modified with cupferron, ß-naphthol, and multiwalled carbo