Journals / Türk Göğüs Kalp Damar Cerrahisi Dergisi / 2016 / Cilt: 24 - Sayı: 4

How ideal is pulmonary autograft for mitral valve replacement?

Pulmoner otogreft mitral kapak replasmanı için ne kadar ideal?

Pages
781–787
Publication Date
2022-09-02
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

For these reasons, pulmonary autografts are not applicable for extensive usage; instead they are a good alternative to be used in selected cases (patients in whom use of warfarin is not practical and extended durability of valve is desired).

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Although significant progress has been achieved in heart surgery since the first successful valve replacement performed in the year 1960, some problems regarding mechanical and bioprosthetic valves still persist.
📊
Key Findings & Data:Towards 2000s, pulmonary autografts came to the fore again for mitral valve replacement.
💡
Conclusion & Impact:For these reasons, pulmonary autografts are not applicable for extensive usage; instead they are a good alternative to be used in selected cases (patients in whom use of warfarin is not practical and extended durability of valve is desired).
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Although significant progress has been achieved in heart surgery since the first successful valve replacement performed in the year 1960, some problems regarding mechanical and bioprosthetic valves still persist. Towards 2000s, pulmonary autografts came to the fore again for mitral valve replacement. These results have been promising for the long-term. However, early-period complications are frequently observed in these operations that are technically challenging and require considerable experience. For these reasons, pulmonary autografts are not applicable for extensive usage; instead they are a good alternative to be used in selected cases (patients in whom use of warfarin is not practical and extended durability of valve is desired).

Özet

1960 yılında yapılan ilk başarılı kapak replasmanından bu yana kalp cerrahisinde büyük ilerlemeler kaydedilmesine rağmen, mekanik ve biyoprotez kapaklar ile ilgili bazı sorunlar halen devam etmektedir. 2000'li yıllara doğru pulmoner otogreftler mitral kapak replasmanı için yeniden gündeme gelmiştir. Bu sonuçlar uzun dönem için umut verici olmuştur. Ancak erken dönem komplikasyonlarının sık görüldüğü bu ameliyatlar teknik olarak zor olup oldukça deneyim gerektirmektedir. Bu nedenlerle pulmoner otogreftler yaygın kullanıma uygun olmayıp, ancak seçilmiş olgularda (varfarin kullanmanın pratik olmadığı ve uzun kapak ömrü istenen hastalar) kullanılabilecek iyi bir alternatiftir.

🔖

Cite This Article

UZUN, K., MANSUROĞLU, D., GÜLER, M., ÖMEROĞLU, S. N. (2022). How ideal is pulmonary autograft for mitral valve replacement?. Türk Göğüs Kalp Damar Cerrahisi Dergisi, Cilt: 24 - Sayı: 4, 781–787. https://ajindex.com/articles/424037

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Cohn LH, Reul RM. Mechanical and bioprosthetic mitral valve replacement. In: Edmunds LH JR, editor. Cardiac Surgery in The Adult. New York: McGraw Hill-Health Profession Division; 1997. p. 1025-50.
  2. Kumar AS, Talwar S, Gupta A. Mitral valve replacement with the pulmonary autograft: midterm results. J Thorac Cardiovasc Surg 2009;138:359-64.
  3. Yankah AC, Klose H, Petzina R, Musci M, Siniawski H, Hetzer R. Surgical management of acute aortic root endocarditis with viable homograft: 13-year experience. Eur J Cardiothorac Surg 2002;21:260-7.
  4. Acar C, Tolan M, Berrebi A, Gaer J, Gouezo R, Marchix T, et al. Homograft replacement of the mitral valve. Graft selection, technique of implantation, and results in forty- three patients. J Thorac Cardiovasc Surg 1996;111:367-78.
  5. Oh W, Somerville J, Ross DN, Ross KJ, Emanuel R. Mitral valve replacement with preserved cadaveric aortic homografts. J Thorac Cardiovasc Surg 1973;65:712-21.
  6. Heng MK, Barratt-Boyes B, Agnew TM, Brandt PW, Kerr AR, Graham KJ. Isolated mitral replacement with stent- mounted antibiotic-treated aortic allograft valves. J Thorac Cardiovasc Surg 1977;74:230-7.
  7. Qureshi SA, Halim MA, Campalani G, Coe YJ, Towers MK, Yacoub MH. Late results of mitral valve replacement using unstented antibiotic sterilised aortic homografts. Br Heart J 1983;50:564-9.
  8. Heimbecker RO, Baird RJ, Lajos TZ, Varga AT, Greenwood WF. Homograft replacement of the human mitral valve. A preliminary report. Can Med Assoc J 1962;86:805-9.
  9. Somerville J, Ross D, Ross JK. Mitral valve replacement with stored inverted pulmonary homograft valve. Thorax 1972;27:583-5. Ross DN. Replacement of aortic and mitral valves with a pulmonary autograft. Lancet 1967;2:956-8.
  10. Joyce F, Tingleff J, Aagaard J, Pettersson G. The Ross operation in the treatment of native and prosthetic aortic valve endocarditis. J Heart Valve Dis 1994;3:371-6.
  11. Ross DN, Kabbani S. Mitral valve replacement with a pulmonary autograft: the mitral top hat. J Heart Valve Dis 1997;6:542-5.
  12. Yacoub MH, Kittle CF. A new technique for replacement of the mitral valve by a semilur valve homograft. J Thorac Cardiovasc Surg 1969;58:859-69.
  13. Kabbani SS, Ross DN, Jamil H, Hammoud A, Nabhani F, Hariri R, et al. Mitral valve replacement with a pulmonary autograft: initial experience. J Heart Valve Dis 1999;8:359-66.
  14. Kabbani S, Jamil H, Nabhani F, Hamoud A, Katan K, Sabbagh N, et al. Analysis of 92 mitral pulmonary autograft replacement (Ross II) operations. J Thorac Cardiovasc Surg 2007;134:902-8. K