Journals / Türk Göğüs Kalp Damar Cerrahisi Dergisi / 2021 / Cilt: 29 - Sayı: 1

Transcatheter closure of the aortopulmonary window in a three-month-old infant with a symmetric membranous ventricular septal defect occluder device

Pages
101–104
Publication Date
2022-09-02
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In conclusion, the use of a symmetric membranous ventricular septal defect device for closure of large aortopulmonary window seems to be a safe and effective alternative to surgery in selected infants.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Although most of aortopulmonary window cases are closed surgically, percutaneous closure can be also used in suitable patients.
📊
Key Findings & Data:A three-month-old male infant weighing 4 kg was referred to our pediatric cardiology department with the complaints of fatigue while breastfeeding, difficulty in weight gain, heart murmur, and respiratory distress.
💡
Conclusion & Impact:In conclusion, the use of a symmetric membranous ventricular septal defect device for closure of large aortopulmonary window seems to be a safe and effective alternative to surgery in selected infants.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Although most of aortopulmonary window cases are closed surgically, percutaneous closure can be also used in suitable patients. Defects which are far from the pulmonary and aortic valves, coronary artery, and pulmonary artery bifurcation, with adequate septal rims are considered suitable for percutaneous closure. A three-month-old male infant weighing 4 kg was referred to our pediatric cardiology department with the complaints of fatigue while breastfeeding, difficulty in weight gain, heart murmur, and respiratory distress. A large aortopulmonary window (5.3 mm) and left heart chamber dilatation were detected on echocardiography. The large aortopulmonary window was closed using a symmetric membranous ventricular septal defect occluder device. The closure procedure was performed via the antegrade route without forming an arteriovenous loop. In conclusion, the use of a symmetric membranous ventricular septal defect device for closure of large aortopulmonary window seems to be a safe and effective alternative to surgery in selected infants.

🔖

Cite This Article

Erdem, A., Karaağaç, A. T., Yıldırım, A. (2022). Transcatheter closure of the aortopulmonary window in a three-month-old infant with a symmetric membranous ventricular septal defect occluder device. Türk Göğüs Kalp Damar Cerrahisi Dergisi, Cilt: 29 - Sayı: 1, 101–104. https://ajindex.com/articles/423611

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Jacobs JP, Quintessenza JA, Gaynor JW, Burke RP, Mavroudis C. Congenital Heart Surgery Nomenclature and Database Project: aortopulmonary window. Ann Thorac Surg 2000;69(4 Suppl):S44-9
  2. Stamato T, Benson LN, Smallhorn JF, Freedom RM. Transcatheter closure of an aortopulmonary window with a modified double umbrella occluder system. Cathet Cardiovasc Diagn 1995;35:165-7
  3. Campos-Quintero A, García-Montes JA, Zabal-Cerdeira C, Cervantes-Salazar JL, Calderón-Colmenero J, Sandoval JP. Transcatheter device closure of aortopulmonary window. Is there a need for an alternative strategy to surgery? Rev Esp Cardiol (Engl Ed) 2019;72:349-51
  4. Trehan V, Nigam A, Tyagi S. Percutaneous closure of nonrestrictive aortopulmonary window in three infants. Catheter Cardiovasc Interv 2008;71:405-11
  5. Sabnis GR, Shah HC, Lanjewar CP, Malik S, Kerkar PG. Transcatheter closure of large aortopulmonary window in a neonate. Ann Pediatr Cardiol 2018;11:228-30
  6. Pillekamp F, Hannes T, Koch D, Brockmeier K, Sreeram N. Transcatheter closure of symptomatic aortopulmonary window in an infant. Images Paediatr Cardiol 2008;10:11-7
  7. Uçar T, Karagözlü S, Ramoğlu MG, Tutar E. Transcatheter closure of aortopulmonary window with Amplatzer duct occluder II: additional size. Cardiol Young 2020;30:424-6
  8. Fiszer R, Zbroński K, Szkutnik M. Percutaneous closure of an aortopulmonary window using Amplatzer Duct Occluder II: Additional Sizes: the first reported case. Cardiol Young 2017;27:812-5
  9. Kosmač B, Eicken A, Kühn A, Heinrich M, Ewert P. Percutaneous device closure of an aortopulmonary window in a small infant. Int J Cardiol 2013;168:e102-3
  10. Odemis E, Guvenc O, Saygi M, Demir IH. Closure of aortopulmonary window using Nit-Occlud® PDA-R device in a 3-month-old infant. Pediatr Int 2016;58:754-6.