Journals / Politeknik Dergisi / 2022 / Cilt: 25 - Sayı: 1

Investigation of the Impacts of Reinforcement Steel’s Diameters on Accelerated Corrosion Begining for the Concretes to which Direct Current Applied

Doğru Akım Uygulanan Betonlarda Donatı Çapının Hızlandırılmış Korozyon Başlangıcına Etkisinin Araştırılması

Pages
381–388
Publication Date
2022-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It has been concluded that, the increase in the diameter of the reinforcement steel in the concrete can decrease the corrosion intensity of the concrete.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, accelerated corrosion test is applied to 300 dosaged concretes whose sizes are 15cm cube.
📊
Key Findings & Data:Reinforcement steel diameters of ø12, ø14 and ø16, respectively, were inserted into the middle points of the concrete.
💡
Conclusion & Impact:It has been concluded that, the increase in the diameter of the reinforcement steel in the concrete can decrease the corrosion intensity of the concrete.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Beton · Hızlandırılmış korozyon · Doğru akım

Abstract

In this study, accelerated corrosion test is applied to 300 dosaged concretes whose sizes are 15cm cube. Reinforcement steel diameters of ø12, ø14 and ø16, respectively, were inserted into the middle points of the concrete. The concrete produced was cured for 28 days after being removed from the molds. In order to achive accelerated corrosion test, 30 V stress intensity is applied by DC power supply. The currents passing through the concretes were recorded with the help of ampere meter and various comparisons were made. It has been concluded that, the increase in the diameter of the reinforcement steel in the concrete can decrease the corrosion intensity of the concrete.

Özet

Bu çalışmada 300 dozajlı, 15cm küp boyutundaki betonlara hızlandırılmış korozyon deneyi uygulanmıştır. Betonların orta noktalarına donatı çapları sırası ile ø12, ø14 ve ø16 olan donatılar yerleştirilmiştir. Üretilen betonlar kalıplardan çıkartıldıktan sonra 28 gün süre ile kür edilmiştir. Betonlarda hızlandırılmış korozyon testi yapabilmek için DC güç kaynağı vasıtası ile 30 V gerilim uygulanmıştır. Betonlara uygulanan akım ampermetre ile kaydedilmiş ve çeşitli karşılaştırmalar yapılmıştır. Beton içerisindeki donatı çapının artması ile betondaki korozyon şiddetinin azaldığı sonucuna ulaşılmıştır.

🔖

Cite This Article

HOCAOĞLU, İ. (2022). Investigation of the Impacts of Reinforcement Steel’s Diameters on Accelerated Corrosion Begining for the Concretes to which Direct Current Applied. Politeknik Dergisi, Cilt: 25 - Sayı: 1, 381–388. https://ajindex.com/articles/422266

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Song H.W., Saraswathy V., “Corrosion monitoring of reinforced concrete structures – a review”, International Journal of Electrochemical Science, 2: 1-28, (2007)
  2. Elsener B., “Corrosion rate of steel in concrete-measurements beyond the tafel law”, Corrosion Science, 47: 3019–3033, (2005)
  3. Zhu W., François R., “Corrosion of the reinforcement and its influence on the residual structural performance of a 26-year-old corroded RC beam”, Construction and Building Materials, 51: 461–472, (2014)
  4. Bicer K., Yalciner H., Balkıs A.P., Kumbasaroglu A., “Effect of corrosion on flexural strength of reinforced concrete beams with polypropylene fibers”, Construction and Building Materials, 185: 574–588, (2018)
  5. Cavaco E.S., Neves L.A.C., Casas, J.R., “Reliability-based approach to the robustness of corroded reinforced concrete structures”, Struct. Conc. 18 (2): 316–325, (2017)
  6. Cao C., Cheung M.M.S “Non-uniform rust expansion for chloride-induced pitting corrosion in RC structures”, Construction and Building Materials, 51: 75–81, (2014)
  7. Bazán A.M., Gálvez J.C, Reyes E., Galé-Lamuela D., “Study of the rust penetration and circumferential stresses in reinforced concrete at early stages of an accelerated corrosion test by means of combined SEM, EDS and strain gauges”, Construction and Building Materials, 184: 655–667, (2018)
  8. Jinwei C., Chuanqing F., Hailong Y., Xianyu Jin., “Corrosion of steel embedded in mortar and concrete under different electrolytic accelerated corrosion methods” Construction and Building Materials 241 (11): 71-79, (2020)
  9. Fu C., Jin N., Ye H., Jin X., Dai W., “Corrosion characteristics of a 4-year naturally corroded reinforced concrete beam with load-induced transverse cracks”, Corrosion Science, 117: 11–23, (2017)
  10. Poupard O., L’Hostis V., Catinaud S., Petre-Lazar I., “Corrosion damage diagnosis of a reinforced concrete beam after 40 years natural exposure in marine environment”, Cem. Concr. Res., 36: 504–520, (2006)
  11. Andrade C., Keddam M., Nóvoa X.R., Pérez, M.C., Rangel, C.M., Takenouti H., “Electrochemical behaviour of steel rebars in concrete: influence of environmental factors and cement chemistry”, Electrochim. Acta 46: 3905–3912, (2001)
  12. Ye H., Jin N., Fu C., Jin X., ”Rust distribution and corrosion-induced cracking patterns of corner-located rebar in concrete cover”, Construction and Building Materials, 156: 684–691, (2017)
  13. Zhang R., Castel A., François R., “Concrete cover cracking with