LAMINAR FLOW OVER SLOPED DOWNSTREAM HEATED BOTTOM WALL BEHIND A BACKWARD-FACING STEP

Pages
1555–1566
Publication Date
2021-10-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It was found that the length of the recirculation region changes slightly with the slope angles at lower Reynolds numbers while it changes dramatically as Reynolds number increases.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In the present three-dimensional study, laminar flow over a backward-facing step was investigated in the framework of the finite volume method for various Reynolds numbers ranging from 100 to 1000.
📊
Key Findings & Data:It was found that the length of the recirculation region changes slightly with the slope angles at lower Reynolds numbers while it changes dramatically as Reynolds number increases.
💡
Conclusion & Impact:Increasing slope angles in both directions also provide a higher local Nusselt number in some distance behind the step.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Backward-facing step · laminar flow · computational fluid dynamics

Abstract

In the present three-dimensional study, laminar flow over a backward-facing step was investigated in the framework of the finite volume method for various Reynolds numbers ranging from 100 to 1000. Attempts were made to clarify the effects of the slope of the downstream heated bottom wall behind the step on the reattachment length and heat transfer. It was found that the length of the recirculation region changes slightly with the slope angles at lower Reynolds numbers while it changes dramatically as Reynolds number increases. The longest length of the recirculation region was obtained at the highest slope angle in the negative vertical-direction while the shortest one was determined at the maximum slope angle in the positive vertical direction. Increasing slope angles in both directions also provide a higher local Nusselt number in some distance behind the step.

🔖

Cite This Article

BAYRAKTAR, S. (2021). LAMINAR FLOW OVER SLOPED DOWNSTREAM HEATED BOTTOM WALL BEHIND A BACKWARD-FACING STEP. Sigma Mühendislik ve Fen Bilimleri Dergisi, Cilt: 38 - Sayı: 3, 1555–1566. https://ajindex.com/articles/419090

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Armaly, B.F., Durst, F., Pereire, J.C.F., Schonung, B., (1983) `Experimental and theoretical investigation of backward-facing step flow, Journal of Fluid Mechanics 127, 473-496
  2. Batenko, S.R., Terekhov, V.I., (2002) Effect of Dynamic Prehistory on Aerodynamics of a Laminar Separated Flow in a Channel Behind a Rectangular Backward-Facing Step, Journal of Applied Mechanics and Technical Physics 43(6), 854-860
  3. Bayraktar, S., (2014) Numerical solution of three-dimensional flow over angled backward-facing step with raised upper wall, Journal of Applied Fluid Mechanics 7(1), 155-167 (2014)
  4. Rygg, K., Alendal, G., Haugan, P.M., (2011) Flow over a rounded backward-facing step using a z-coordinate model and a -coordinate model, Ocean Dynamics 61, 1681-1696
  5. Chuhn, K.B., Sung, H.J., (1996) Control of turbulent separated flow over a backward-facing step by local forcing, Experiments in Fluids 21, 417-426
  6. Tsay, Y.L., Chang, T.S., Cheng, J.C. (2005) Heat transfer enhancement of backward-facing step flow in a channel by using baffle installation on the channel wall, Acta Mechanica 174, 63-76
  7. Khanafer, K., Al-Azmi, B., Al-Shammari, A., Pop, I., (2008) Mixed convection analysis of laminar pulsating flow and heat transfer over a backward-facing step, International Journal of Heat and Mass Transfer 51, 5785-5793
  8. Selimefendigil, F., Oztop, H., (2016) Numerical study of forced convection of nanofluid flow over a backward facing step with corrugated bottom wall in the presence of different shaped obstacles, Heat Transfer Engineering 37(15), 1280-1292
  9. Togun, H., (2016) Laminar CuO-water nano-fluid flow and heat transfer in a backward-facing step with and without obstacle, Applied Nanoscience 6, 374-378
  10. Terekhov, V.I., Bogatho, T.V., (2015) Aerodynamics and Heat Transfer in a Separated Flow in an Axisymmetric Diffuser with Sudden Expansion, Journal of Applied Mechanics and Technical Physics, 56(3), 471-478
  11. Sheu, T.W.H., Rani, H.P., (2006) Exploration of vortex dynamics for transitional flows in a three-dimensional backward-facing step channel, Journal of Fluid Mechanics 550, 61-83
  12. Chiang, T.P., Sheu. T.W.H., A. (1999) Numerical Revisit of Backward-Facing Step Flow Problem, Physics of Fluids, 11(4), 862-874
  13. Gong, Y., Tanner, F.X., (2009) Comparison of RANS and LES Models in the Laminar Limit for a Flow over a Backward-Facing Step Using OpenFOAM, 9th International Multidimensional Engine Modeling Meeting at the SAE