Journals / Turkish Thoracic Journal / 2020 / Cilt: 21 - Sayı: 5

Is it Possible to Use the Timed Performance Tests in Lung Transplantation Candidates to Determine the Exercise Capacity?

Pages
329–333
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The timed performance tests may be alternative tests to determine exercise capacity in LTx candidates.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:OBJECTIVES: Lung transplantation (LTx) candidates have severe exercise intolerance.
📊
Key Findings & Data:We aimed to investigate the use of short-timed performance tests instead of 6-minute walk test (6MWT) in the determination of exercise capacity in LTx.MATERIALS AND METHODS: A total of 63 LTx candidates were included in the study.
💡
Conclusion & Impact:The timed performance tests may be alternative tests to determine exercise capacity in LTx candidates.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

OBJECTIVES: Lung transplantation (LTx) candidates have severe exercise intolerance. This makes it difficult for them to complete the field tests used to determine the exercise capacity of patients. Therefore, there is a need for alternative tests that require less effort. We aimed to investigate the use of short-timed performance tests instead of 6-minute walk test (6MWT) in the determination of exercise capacity in LTx.MATERIALS AND METHODS: A total of 63 LTx candidates were included in the study. Ten-meter walking speed test (10MWT), 5-times sit-to-stand test (5XSST), 6MWT were performed at one-hour intervals within the same day, and by the same physiotherapist in all patients. Maximal inspiratory (MIP) and expiratory pressure (MEP), peripheral muscle strengths, pulmonary function tests, and body mass index (BMI) were recorded for each patient.RESULTS: The subjects’ baseline mean 6-minute walking distance (6MWD) was 336m, 5XSST time was 11.59 sec, and 10MWT time was 8.45sec. There was a negative and moderate correlation between 6MWD and 10MWT (p<0.001, r=0.449). Similarly there was a negative but weak correlation between 6MWD and 5XSST (p=0.001, r=0.397). In addition, there was a strong relationship between 5XSST and 10MWT (p<0.001, r=0.767).CONCLUSION: This study showed that 6MWT and short-timed performance tests were correlated in terms of exercise capacity assessment. In contrast, there was a strong relationship between 6MWT and 10MWT according to 6MWT and 5XSST. The timed performance tests may be alternative tests to determine exercise capacity in LTx candidates.

🔖

Cite This Article

PEHLİVAN, E., BALCI, A., KILIÇ, L., YAZAR, E. (2020). Is it Possible to Use the Timed Performance Tests in Lung Transplantation Candidates to Determine the Exercise Capacity?. Turkish Thoracic Journal, Cilt: 21 - Sayı: 5, 329–333. https://ajindex.com/articles/417941

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Kugler C, Gottlieb J, Warnecke G, et al. Health-related quality of life after solid organ transplantation: a prospective, multiorgan cohort study. Transplantation 2013
  2. [Crossref] 2. Didsbury M, McGee RG, Tong A, et al. Exercise training in solid organ transplant recipients: A systematic review and meta-analysis. Transplantation 2013
  3. [Crossref] 3. Moran J, Wilson F, Guinan E, et al. The preoperative use of field tests of exercise tolerance to predict postoperative outcome in intra-abdominal surgery: a systematic review. J Clin Anesth 2016
  4. [Crossref] 4. Hattori K, Matsuda T, Takagi Y, et al. Preoperative six-minute walk distance is associated with pneumonia after lung resection. Interact Cardiovasc Thorac Surg 2018
  5. [Crossref] 5. Holland AE, Spruit MA, Troosters T, et al. An official European Respiratory Society/American Thoracic Society technical standard: Field walking tests in chronic respiratory disease. Eur Respir J 2014
  6. [Crossref] 6. Araujo CG, Herdy AH, Stein R. Maximum oxygen consumption measurement: valuable biological marker in health and in sickness. Arq Bras Cardiol 2013, 100:e51-53. [Crossref] 7. Patel M, Canavan J, Clark A, et al. The effect of pulmonary rehabilitation on the sit-to-stand test in COPD. Eur Respir J 2011
  7. p1232. 8. Puthoff ML, Youngs B. Cardiac Rehabilitation Leads to Improvements in Activity Limitations. J Cardiopulm Rehabil Prev 2017
  8. [Crossref] 9. Kerr A, Clark A, Cooke EV, et al. Functional strength training and movement performance therapy produce analogous improvement in sit-to-stand early after stroke: early-phase randomised controlled trial. Physiotherapy 2017
  9. [Crossref] 10. Hutin E, Ghedira M, Loche CM, et al. Intra- and inter-rater reliability of the 10-meter ambulation test in hemiparesis is better barefoot at maximal speed. Top Stroke Rehabil 2018
  10. [Crossref] 11. Brooks D, Solway S, Gibbons WJ. ATS statement on six-minute walk test. Am J Respir Crit Care Med 2003
  11. doi: 10.1164/ajrccm.167.9.950. [Crossref] 12. Paul SS, Canning CG. Five-repetition sit-to-stand. J Physiother 2014
  12. doi: 10.1016/j.jphys.2014.06.002. [Crossref] 13. Duncan RP, Combs-Miller SA, McNeely ME, et al. Are the average gait speeds during the 10meter and 6minute walk tests redundant in Parkinson disease? Gait Posture 2016, 52:178-182. [Crossref] 14. Pehlivan E, Balci A, Kilic L, Kadakal F. Preoperative Pulmonary Rehabilitation for Lung Transp