Journals / Bağcılar Tıp Bülteni / 2021 / Cilt: 6 - Sayı: 3

Sağlıklı Yenidoğanlarda ve Solunum Yetmezliği Olan Yenidoğanlarda Ardışık İki Yüksek Duyarlılıklı Kardiyak Troponin T Ölçümünün Değerlendirilmesi

Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure

Pages
287–294
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Her iki hs cTnT değeri, yenidoğan solunum yetmezliği grubunda sağlıklı gruba göre çok artmıştır

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Yenidoğanlarda yüksek duyarlılıklı kardiyak Troponin T’nin (hs cTnT) göbek kordonu ve doğum sonrası fizyolojik sınırlarına ilişkin veriler azdır.
📊
Key Findings & Data:Bu çalışma sağlıklı yenidoğanlarda hs cTnT’nin normal değerlerini ve üst sınırlarını belirlemeyi amaçlamaktadır.
💡
Conclusion & Impact:Her iki hs cTnT değeri, yenidoğan solunum yetmezliği grubunda sağlıklı gruba göre çok artmıştır
🔬Design:Research Article
📍Scope:2018 Verileri
⚙️Variables:Domain Parameters

Abstract

Amaç: Yenidoğanlarda yüksek duyarlılıklı kardiyak Troponin T’nin (hs cTnT) göbek kordonu ve doğum sonrası fizyolojik sınırlarına ilişkin veriler azdır. Bu çalışma sağlıklı yenidoğanlarda hs cTnT’nin normal değerlerini ve üst sınırlarını belirlemeyi amaçlamaktadır. Ayrıca, yenidoğan solunum yetmezliğinde klinik önemi ve kullanılabilirliği analiz edilmiştir. Yöntem: Bu invazif olmayan ve retrospektif, kesitsel çalışmada, Temmuz 2018 ile Ocak 2020 tarihleri arasında doğan 113 sağlıklı yenidoğan ve kalp dışı kaynaklı solunum yetmezliği olan 93 yenidoğan değerlendirildi. Hs cTnT, bebeklerde göbek kordonunda ve doğumdan 24-96 saat sonra ölçüldü. Bulgular: Sağlıklı grupta umbilikal kord hs cTnT medyan 38 (17-156) ng/L; 99. persantil hs cTnT 122 ng/L, solunum yetmezliği grubunda umbilikal kord hs cTnT medyan 72 (27-326) ng/L bulundu. Sağlıklı grupta postnatal 2-4 gün hs cTnT medyan 75 (10-194) ng/L; 99. persantil 194 ng/L, solunum yetmezliği grubunda hs cTnT medyan 145 (41-409) idi. Göbek kordonu için hs cTnT ROC eğrisi eğrinin altındaki alan değeri 0,848 [cut-off 64: %95 güven aralığı (GA): 0,79-0,90, duyarlılık: %62,4, özgüllük: %93,7], göbek kordonu hs cTnT’nin yenidoğan solunum yetmezliğinin tahmini için duyarlı bir belirteç olduğunu düşündürmektedir. Kontrol hs cTnT ROC eğrisi eğrinin altındaki alan değeri 0,851 (cut-off: 121,5, %95 GA: 0,79-0,90, duyarlılık: %71, özgüllük: %86,8), kontrol hs cTnT’nin neonatal solunum yetmezliğinin tahmini için duyarlı bir belirteç olduğunu göstermektedir. Sonuç: Sağlıklı yenidoğanlarda umbilikal kord ve postnatal hs cTnT referans aralığının, erişkin değerlerine göre yüksek olduğu saptanmıştır. Her iki hs cTnT değeri, yenidoğan solunum yetmezliği grubunda sağlıklı gruba göre çok artmıştır

Özet

Objective: Data on the umbilical cord and postnatal physiological limits of the high sensitivity cardiac troponin T (hs cTnT) in newborns are scarce. This study aims to determine the normal values and upper limits of hs cTnT in healthy newborns. In addition, its clinical significance and usability in neonatal respiratory failure were analyzed. Method: In this non-invasive and retrospective, cross-sectional study, 113 healthy newborns and 93 newborns with non-cardiac respiratory failure, born between July 2018 and January 2020, were evaluated. Hs cTnT was measured in the umbilical cord and 24-96 h after birth in infants. Results: In the healthy group, the median umbilical cord hs cTnT was 38 (17-156) ng/L and 99th percentile hs cTnT was 122 ng/L, and in the respiratory failure group, the median umbilical cord hs cTnT was 72 (27- 326) ng/L. Postnatal day 2-4 median hs cTnT was 75 (10-194) ng/L and 99th percentile value was 194 ng/L in the healthy group, and the median hs cTnT was 145 (41-409) ng/L in the respiratory failure group. The calculated area under the ROC curve for umbilical cord hs cTnT was 0.848 [cut-off: 64, 95% confidence interval (CI): 0.79-0.90, sensitivity: 62.4%, specificity: 93.7%], suggesting that umbilical cord hs cTnT is a sensitive marker for the prediction of neonatal respiratory failure. The calculated area under the ROC curve for control hs cTnT was 0.851 (cut-off: 121.5, 95% CI: 0.79- 0.90, sensitivity: 71%, specificity: 86.8%), suggesting that control hs cTnT is a sensitive marker for the prediction of neonatal respiratory failure. Conclusion: The results show that the reference range of umbilical cord and postnatal hs cTnT in healthy newborns is higher than that in adults. Both hs cTnT values were higher in the neonatal respiratory failure group than those in the healthy group.

🔖

Cite This Article

TÜFEKCİ, S., KIZILCA, Ö., ÇELIKKOL, A., TOPÇU, B. (2021). Sağlıklı Yenidoğanlarda ve Solunum Yetmezliği Olan Yenidoğanlarda Ardışık İki Yüksek Duyarlılıklı Kardiyak Troponin T Ölçümünün Değerlendirilmesi. Bağcılar Tıp Bülteni, Cilt: 6 - Sayı: 3, 287–294. https://ajindex.com/articles/413765

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Bettencourt P. NT-proBNP and BNP: biomarkers for heart failure management. Eur J Heart Fail 2004;6(3):359-363
  2. Bhayana V, Henderson AR. Biochemical markers of myocardial damage. Clin Biochem 1995;28(1):1-29
  3. Simovic A, Stojkovic A. Correlation level of cardiac troponin-i with total duration of oxygen / ventilator therapy in the term newborns with respiratory distress. J Cardiovasc Dis Diagn 2014;2:5
  4. Braunwald E, Fauci AS, Kasper DL. Harrison’s Principles of Internal Medicine, 15th ed. New York: McGraw-Hill; 2001
  5. Clark SJ, Newland P, Yoxall CW, Subhedar NV. Cardiac troponin T in cord blood. Arch Dis Child Fetal Neonatal Ed 2001;84(1):F34-F37
  6. Jehlicka P, Huml M, Rajdl D, Mockova A, Matas M, Dort J, et al. How to interpret elevated plasmatic level of high-sensitive troponin T in newborns and infants? Physiol Res 2018;67(2):191-195
  7. Clark SJ, Newland P, Yoxall CW, Subhedar NV. Concentrations of cardiac troponin T in neonates with and without respiratory distress. Arch Dis Child Fetal Neonatal Ed 2004;89(4):F348-F52
  8. Joseph S, Kumar S, Ahamed MZ, Lakshmi S. Cardiac troponin T as a marker of myocardial dysfunction in term neonates with perinatal asphyxia. Indian J Pediatr 2018;85(10):877-884
  9. El-Khuffash AF, Molloy EJ. Influence of a patent ductus arteriosus on cardiac troponin T levels in preterm infants. J Pediatr 2008;153(3):350-353
  10. Thygesen K, Alpert JS, Jaffe AS, Chaitman BR, Bax JJ, Morrow DA, et al; Executive Group on behalf of the Joint European Society of Cardiology (ESC)/American College of Cardiology (ACC)/ American Heart Association (AHA)/World Heart Federation (WHF) Task Force for the Universal Definition of Myocardial Infarction. Fourth universal definition of myocardial infarction (2018). Circulation 2018;138(20):e618-e651
  11. Sweet DG, Carnielli V, Greisen G, Hallman M, Ozek E, Te Pas A, et al. European Consensus Guidelines on the management of respiratory distress syndrome - 2019 update. Neonatology 2019;115(4):432-450
  12. Giannitsis E, Kurz K, Hallermayer K, Jarausch J, Jaffe AS, Katus HA. Analytical validation of a high-sensitivity cardiac troponin T assay. Clin Chem 2010;56(2):254-261
  13. Awada H, Al-Tannir M, Ziade MF, Alameh J, El Rajab M. Cardiac troponin T: a useful early marker for cardiac and respiratory dysfunction in neonates. Neonatology 2017;92(2):105-110
  14. Karlén J, Karlsson M, Eliasson H, Bonamy AE, Halvorsen CP. Cardiac troponin t in healthy full-term ınfants. Pediatr Cardiol 2019;40(8):16