AI Summary & Key Takeaways
AI Insight⚡ TL;DR(Too Long; Didn't Read)
We have observed hypotensive reaction similar to those reported in the literature following random donor platelet transfusion using bedside white cell-reduction filter in a chronic lymphocytic leukemia patient who was treated with ACE inhibitor for her systemic hypertension
📌 3 Key Takeaways
🎯
Objective & Hypothesis:Hypotensive episodes in patients receiving platelet concentrates through white-cell reduction filters have been reported previously.
📊
Key Findings & Data:Hypotensive episodes in patients receiving platelet concentrates through white-cell reduction filters have been reported previously.
💡
Conclusion & Impact:We have observed hypotensive reaction similar to those reported in the literature following random donor platelet transfusion using bedside white cell-reduction filter in a chronic lymphocytic leukemia patient who was treated with ACE inhibitor for her systemic hypertension
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Trombosit transfüzyonu · Hipertansiyon · Lökositler
Özet
Hypotensive episodes in patients receiving platelet concentrates through white-cell reduction filters have been reported previously. We have observed hypotensive reaction similar to those reported in the literature following random donor platelet transfusion using bedside white cell-reduction filter in a chronic lymphocytic leukemia patient who was treated with ACE inhibitor for her systemic hypertension
🔖
Cite This Article
ARSLAN, Ö., ELKIRAN, T., ARAT, M., İLHAN, O., KOÇ, H. (2001). Severe hypotensive reaction due to a bedside white cell reduction filter. Turkish Journal of Hematology, Cilt: 18 - Sayı: 1, 59–61. https://ajindex.com/articles/412974