Journals / Turkish Journal of Hematology / 2000 / Cilt: 17 - Sayı: 4

Biological dosimetry of Co-60 gamma irradiation

Pages
189–196
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Estimated radiation doses were below the permissible radiation dose-limits for four workers, but one worker's estimated dose was higher than these limits.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Development of radiation technology has resulted in increasing numbers of people working with it.
📊
Key Findings & Data:In this study Co-60 gamma radiation doseresponse curves for chromosome aberrations were determined for use as controls in biological dosimetry.
💡
Conclusion & Impact:Estimated radiation doses were below the permissible radiation dose-limits for four workers, but one worker's estimated dose was higher than these limits.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Radyometri · Doz-yanıt ilişkisi · radyasyon

Özet

Development of radiation technology has resulted in increasing numbers of people working with it. Therefore it has increasingly been important to monitor the radiation in order to ensure public safety. Physical dosimetry plays an important role in monitoring. But a need arise for biological dosimetry whe-re physical dosimetry is absent or its presence is insufficient. In this study Co-60 gamma radiation doseresponse curves for chromosome aberrations were determined for use as controls in biological dosimetry. Peripheral blood that were taken from healthy indi-viduals not working with radiation were irradiated at different radiation doses. The relationship between unstable chromosome aberrations in metaphaseblocked cells and radiation dose were drawn by using the linear-quadratic (LQ) formula. The absorbed radiation doses of the test group consisting of five people that had been working with Co-60 teletherapy machines were estimated using the LQ parameters of control dose-response curves in the $Q_dr$ method. Estimated radiation doses were below the permissible radiation dose-limits for four workers, but one worker's estimated dose was higher than these limits.

🔖

Cite This Article

TOP, A., COŞKUN, M., ORTA, T. (2000). Biological dosimetry of Co-60 gamma irradiation. Turkish Journal of Hematology, Cilt: 17 - Sayı: 4, 189–196. https://ajindex.com/articles/412971

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...