Journals / Turkish Neurosurgery / 2018 / Cilt: 28 - Sayı: 6

Usefulness and Radiological Evaluation of Accuracy of the Innovative “Smart” Hand Technique for Pedicle Screw Placement: An Anatomical Study

Pages
866–876
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This may lead to a useful mobile digital angle-meter for spinal procedures.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AIM: To use a smartphone application (app) during pedicle screw placement navigation and examine the accuracy of this applicationon an anatomical dry vertebrae model.MATERIAL and METHODS: Seventy-six dry vertebrae were used for this study, and pedicle entry points and projections ofpedicle screw trajectory lines in the lateral and superior aspects of the vertebral body were identified and drawn for each vertebrabilaterally.
📊
Key Findings & Data:Accuracy of the methodwas tested according to the occurrence of bone penetration while the angular deviation of the inserted screws was evaluated incomputed tomography images.RESULTS: The mean deviation for 76 pedicle screws on the right side was 2.30°±1.78° in the horizontal plane and 2.17°±1.57° inthe sagittal plane; and on the left side, 3.01°±1.83° in the horizontal plane and 2.38°±1.68° in the sagittal plane.
💡
Conclusion & Impact:This may lead to a useful mobile digital angle-meter for spinal procedures.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

AIM: To use a smartphone application (app) during pedicle screw placement navigation and examine the accuracy of this applicationon an anatomical dry vertebrae model.MATERIAL and METHODS: Seventy-six dry vertebrae were used for this study, and pedicle entry points and projections ofpedicle screw trajectory lines in the lateral and superior aspects of the vertebral body were identified and drawn for each vertebrabilaterally. In each position, all angulations were measured directly before the procedure manually. One hundred and fifty two pediclescrews were inserted as a simulation of screw placement with the guidance of the angle-meter smart app. Accuracy of the methodwas tested according to the occurrence of bone penetration while the angular deviation of the inserted screws was evaluated incomputed tomography images.RESULTS: The mean deviation for 76 pedicle screws on the right side was 2.30°±1.78° in the horizontal plane and 2.17°±1.57° inthe sagittal plane; and on the left side, 3.01°±1.83° in the horizontal plane and 2.38°±1.68° in the sagittal plane. No bone penetrationoccurred during 152 pedicle screw placements. According to the t-test results, there were significant differences between the twogroups in the craniocaudal direction of the right side pedicle screws and in the craniocaudal direction of left sided pedicle screws.CONCLUSION: The free smartphone app presented here as an angle-meter is a safe digital device for spinal instrumentationprocedures. As a prototype of future pedicle screw fixation systems, it should be improved in terms of its feasibility and compatibilitywith screw probes. This may lead to a useful mobile digital angle-meter for spinal procedures.

🔖

Cite This Article

CÖMERT, A., DOĞAN, İ., ÇAĞLAR, Y. Ş. (2018). Usefulness and Radiological Evaluation of Accuracy of the Innovative “Smart” Hand Technique for Pedicle Screw Placement: An Anatomical Study. Turkish Neurosurgery, Cilt: 28 - Sayı: 6, 866–876. https://ajindex.com/articles/405313

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Dogan I, Eroglu U, Ozgural O, Al-Beyati ESM, Kilinc MC, Comert A, Bozkurt M: Visualization of superficial cerebral lesions using a smartphone application. Turk Neurosurg 28(3):349-355, 2018 Eftekhar B: A smartphone app to assist scalp localization of superficial supratentorial lesions-technical note. World Neurosurg 85:359-363, 2016 Eftekhar B: App-assisted external ventricular drain insertion. J Neurosurg 125:754-758, 2016
  2. Kahn JG, Yang JS, Kahn JS: 'Mobile' health needs and opportunities in developing countries. Health Aff (Millwood) 29:252-258, 2010
  3. Kim YJ, Lenke LG: Thoracic pedicle screw placement: Freehand technique. Neurol India 53:512–519, 2005
  4. Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD: Free hand pedicle screw placement in the thoracic spine: Is it safe? Spine 29:333–342, 2004
  5. Kotani Y, Abumi K, Ito M, Minami A: Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257–263, 2003
  6. Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H: Improved accuracy of pedicle screw insertion with computer assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258, 1997
  7. Mobasheri MH, Johnston M, Syed UM, King D, Darzi A: The uses of smartphones and tablet devices in surgery: A systematic review of the literature. Surgery 158:1352-1371, 2015
  8. Panjabi MM, Takata K, Goel V, Federico D, Oxland T, Duranceau J, Krag M: Thoracic human vertebrae. Quantitative three-dimensional anatomy. Spine 16:888–901, 1991
  9. Payne KB, Wharrad H, Watts K: Smartphone and medical related App use among medical students and junior doctors in the United Kingdom (UK): A regional survey. BMC Med Inform Decis Mak 12:121, 2012
  10. Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP: Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine 32:E56–E64, 2007
  11. Roy-Camille R, Saillant G, Mazel C: Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7–17, 1986
  12. Tian NF, Huang QS, Zhou P, Zhou Y, Wu RK, Lou Y, Xu HZ: Pedicle screw insertion accuracy with different assisted methods: A systematic review and meta-analysis of comparative studies. Eur Spine J 20:846–859, 2011
  13. Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM: Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg (Am) 77:1193–1199, 1995
  14. Vaccaro AR, Rizz