Journals / Turkish Neurosurgery / 2016 / Cilt: 26 - Sayı: 2

Dynamic Radiographic Results of Different Semi-Rigid Fusion Devices for Degenerative Lumbar Spondylolisthesis: "Dynamic Rod" vs. "Dynamic Screw Head"

Pages
268–273
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

CONClUSION: These outcomes may play a role in decreasing the risk of ASD after dynamic stabilization, at least 2 years after surgery.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AIM: To assess the clinical outcomes and compare the segmental range of motion (ROM) at the implanted L4-L5 level, the cranial and caudal adjacent levels, and the ROM of the whole lumbar spine after semi-rigid lumbar fusion with 2 different devices.
📊
Key Findings & Data:MATERIAl and METhODS: Patients with neurogenic claudication, due to grade 1 spondylolisthesis and spinal stenosis at levels L4-L5, were treated either Bio-flex® (n = 28) and Cosmic® (n = 23); discectomy was not performed at any level.
💡
Conclusion & Impact:CONClUSION: These outcomes may play a role in decreasing the risk of ASD after dynamic stabilization, at least 2 years after surgery.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

AIM: To assess the clinical outcomes and compare the segmental range of motion (ROM) at the implanted L4-L5 level, the cranial and caudal adjacent levels, and the ROM of the whole lumbar spine after semi-rigid lumbar fusion with 2 different devices. MATERIAl and METhODS: Patients with neurogenic claudication, due to grade 1 spondylolisthesis and spinal stenosis at levels L4-L5, were treated either Bio-flex® (n = 28) and Cosmic® (n = 23); discectomy was not performed at any level. The clinical outcomes were compared between the 2 groups. All patients underwent neutral, flexion, and extension radiography before the surgery and after 2 years postoperatively. ROM was assessed at the level of L4-L5, L3-L4, L5-S1, and at the whole lumbar spine. RESUlTS: According to clinical outcomes, 82% and 78% of patients in the BioFlex and Cosmic groups, respectively, had a good or excellent result. In both groups, there was significant reduction of the segmental ROM at the implanted L4-L5 level (p = 0.039 and 0.011). CONClUSION: These outcomes may play a role in decreasing the risk of ASD after dynamic stabilization, at least 2 years after surgery.

🔖

Cite This Article

YANG, J. S., CHO, Y. J., KANG, S. H., CHOI, H. J. (2016). Dynamic Radiographic Results of Different Semi-Rigid Fusion Devices for Degenerative Lumbar Spondylolisthesis: "Dynamic Rod" vs. "Dynamic Screw Head". Turkish Neurosurgery, Cilt: 26 - Sayı: 2, 268–273. https://ajindex.com/articles/404714

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Bozkus H, Senoglu M, Baek S, Sawa AG, Ozer AF, Sonntag VK, Crawford NR: Dynamic lumbar pedicle screw-rod stabilization: In vitro biomechanical comparison with standard rigid pedicle screw-rod stabilization. J Neurosurg Spine 12:183-189, 2010 2. Cakir B, Carazzo C, Schmidt R, Mattes T, Reichel H, Kafer W: Adjacent segment mobility after rigid and semirigid instrumentation of the lumbar spine. Spine (Phila Pa 1976) 34: 1287-1291, 2009 3. Canbay S, Aydin AL, Aktas E, Erten SF, Basmaci M, Sasani M, Ozer AF: Posterior dynamic stabilization for the treatment of patients with lumbar degenerative disc disease: Long-term clinical and radiological results. Turk Neurosurg 23:188-197, 2013 4. Fay LY, Wu JC, Tsai TY, Wu CL, Huang WC, Cheng H: Dynamic stabilization for degenerative spondylolisthesis: Evaluation of radiographic and clinical outcomes. Clin Neurol Neurosurg 115(5): 535-541, 2013 5. Fritz JM, Erhard RE, Hagen BF: Segmental instability of the lumbar spine. Phys Ther 78:889-896,1998 6. Heo DH, Cho YJ, Cho SM, Choi HC, Kang SH: Adjacent segment degeneration after lumbar dynamic stabilization using pedicle screws and a nitinol spring rod system with 2-year minimum follow-up. J Spinal Disord Tech 25(8):409-414, 2012 7. Ilharreborde B, Shaw MN, Berglund LJ, Zhao KD, Gay RE, An KN: Biomechanical evaluation of posterior lumbar dynamic stabilization: An in vitro comparison between Universal Clamp and Wallis systems. Eur Spine J 20:289-296, 2011 8. Kanayama M, Togawa D, Hashimoto T, Shigenobu K, Oha F: Motion-preserving surgery can prevent early breakdown of adjacent segments: Comparison of posterior dynamic stabilization with spinal fusion. J Spinal Disord Tech 22: 463-467, 2009 9. Kim CH, Chung CK, Jahng TA: Comparisons of outcomes after single or multilevel dynamic stabilization: Effects on adjacent segment. J Spinal Disord Tech 24: 60-67, 2011 10. Kumar A, Beastall J, Hughes J, Karadimas EJ, Nicol M, Smith F, Wardlaw D: Disc changes in the bridged and adjacent segments after Dynesys dynamic stabilization system after two years. Spine (Phila Pa 1976) 33:2909-2914, 2008 11. Lee MJ, Lindsey JD, Bransford RJ: Pedicle screw-based posterior dynamic stabilization in the lumbar spine. J Am Acad Orthop Surg 18: 581-588, 2010 12. McCullough BJ, Johnson GR, Martin BI, Jarvik JG: Lumbar MR imaging and reporting epidemiology: Do epidemiologic data in reports affect clinical management? Radiology 262:941-946, 2012 13. Oktenoglu T, Ozer AF, Sasani M, Kaner T, Canbulat N, Erc