⚡ TL;DR(Too Long; Didn't Read)

CONClUSION: CO2 laser soldering for dural defect reconstruction was feasible and reliable.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AIM: To explore the feasibility and reliability of CO2 laser soldering on the reconstruction of dura mater in the minipig model.
📊
Key Findings & Data:MATERIAl and METhODS: Ten minipigs were divided into 2 groups as Group A (n=5) and Group B (n=5).
💡
Conclusion & Impact:CONClUSION: CO2 laser soldering for dural defect reconstruction was feasible and reliable.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

AIM: To explore the feasibility and reliability of CO2 laser soldering on the reconstruction of dura mater in the minipig model. MATERIAl and METhODS: Ten minipigs were divided into 2 groups as Group A (n=5) and Group B (n=5). Bilateral fronto-parietal craniotomy was performed and 2cm×1cm dural defect created under general anesthesia. Then, the defect was repaired with autologous temporalis fascia by CO2 laser soldering. After pressure and watertightness testing, the minipigs of group A were sacrificed immediately. Minipigs in Group B were followed for 4 weeks, with daily monitoring of behavior, food intake, skin incision and neurological condition. Animals of Group B were also subjected to the same tests as group A. Then, they were also sacrificed. The reconstructed area and underlying brain tissue were fixed in paraformaldehyde and submitted for histological analysis. RESUlTS: No neural impairment, hydrops or empyema, and no cerebrospinal fluid leak in the dura-fascia interface were observed in Group B. The mean burst pressures were higher than the mean intracranial crest pressure in groups A and B. This difference was significant (P=0.010, P=0.000, respectively). The physiological intracranial pressure of ten minipigs ranged between 4.53 and 6.47 mmHg. No thermal injury was observed in either group. CONClUSION: CO2 laser soldering for dural defect reconstruction was feasible and reliable.

🔖

Cite This Article

ZHONG, H., WANG, Z., YANG, Z., ZHAO, F., WANG, B., LIU, P. (2016). CO Laser Soldering for the Reconstruction of Dural Defects in the Minipig Model. Turkish Neurosurgery, Cilt: 26 - Sayı: 2, 240–245. https://ajindex.com/articles/404713

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. Bass LS, Moazami N, Pocsidio J, Oz MC, Logerfo P, Treat MR: Changes in type I collagen following laser welding. Lasers Surg Med 12: 500-505, 1992 2. Boord M: Laser in dermatology. Clin Tech Small Anim Pract 21: 145-149, 2006 3. Briggs R, Wormald PJ: Endoscopic transnasal intradural repair of anterior skull base cerebrospinal fluid fistulae. J Clin Neurosci 11: 597-599, 2004 4. Chikamatsu E, Sakurai T, Nishikimi N, Yano T, Nimura Y: Comparison of laser vascular welding, interrupted sutures, and continuous sutures in growing vascular anastomoses. Lasers Surg Med 16: 34-40, 1995 5. Durham L, Willatt D, Yung M, Jones I, Stevenson P, Ramadan M: A method for preparation of fibrin glue. J Laryngol Otol 101:1182- 1186, 1987 6. Fliss DM, Gil Z, Spektor S, Leider-Trejo L, Abergel A, Khafif A, Amir A, Gur E, Cohen JT: Skull base reconstruction after anterior subcranial tumor resection. Neurosurg Focus 12:e10, 2002 7. Forer B, Vasilyev T, Brosh T, Kariv N, Trejo LL, Gil Z, Katzir A, Fliss DM: Dural defect repair with fascia by a CO2 laser system in a porcine model. Laryngoscope 116: 1002-1006, 2006 8. Forer B, Vasileyev T, Gil Z, Brosh T, Kariv N, Katzir A, Fliss DM: CO2 Laser fascia to dura soldering for pig dural defect reconstruction. Skull Base 17: 17-24, 2007 9. Foyt D, Johnson JP, Kirsch AJ, Bruce JN, Wazen JJ: Dural closure with laser tissue welding. Otolaryngol Head Neck Surg 115:513- 518, 1996 10. Gil Z, Shaham A, Vasilyev T, Brosh T, Forer B, Katzir A, Fliss DM: Novel laser tissue-soldering technique for dural reconstruction. J Neurosurg 103: 87-91, 2005 11. Goldsmith HS, Steward E, Duckett S: Early application of pedicled omentum to the acutely traumatised spinal cord. Paraplegia 23: 100-112, 1985 12. Hadley MN, Martin NA, Spetzler RF, Sonntag V, Johnson PC: Comparative transoral dural closure techniques: A canine model. Neurosurgery 22: 392-397 1988 13. Hasegawa M, Torii S, Fukuta K, Saito K: Reconstruction of the anterior cranial base with the galeal frontalis myofascial flap and the vascularized outer calvarial bone graft. Neurosurgery 36: 725- 729
  2. discussion 729-731, 1995 14. Kanellopoulos AJ: Laser cataract surgery: A prospective clinical evaluation of 1000 consecutive laser cataract procedures using the Dodick photolysis Nd: YAG system. Ophthalmology 108: 649- 654, 2001 15. Keener EB: Regeneration of dural defects
  3. a review. J Neurosurg 16: 415-423, 1959 16. Keller GS: Method of laser cosmetic surgery. In: Google Patents, 1994 17. Kirschner R: Las