Journals / Turkish Neurosurgery / 2017 / Cilt: 27 - Sayı: 3

Multimodal Intraoperative Neurophysiological Monitoring in Spinal Cord Surgery

Pages
436–440
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

CONClUSION: Multimodal IONM is an important method to monitor the neural structures under risk in spine surgery and to keep the surgery within safety limits, especially for intramedullary spinal cord lesion surgery.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AIm: Intraoperative neurophysiological monitoring (IONM) monitors the functional integrity of critical neural structures by electrophysiological methods during surgery.
📊
Key Findings & Data:Our aim was to share our intraoperative monitoring experiences with patients who underwent surgery because of spinal cord pathologies between September 2013 and January 2015. mATERIAl and mEThODS: We had twenty-six cases.
💡
Conclusion & Impact:CONClUSION: Multimodal IONM is an important method to monitor the neural structures under risk in spine surgery and to keep the surgery within safety limits, especially for intramedullary spinal cord lesion surgery.
🔬Design:Research Article
📍Scope:2013 Verileri
⚙️Variables:Domain Parameters

Özet

AIm: Intraoperative neurophysiological monitoring (IONM) monitors the functional integrity of critical neural structures by electrophysiological methods during surgery. Multimodality combines different neurophysiological methods to maximize diagnostic efficacy and provide a safety margin to improve the outcomes of spinal surgery. Our aim was to share our intraoperative monitoring experiences with patients who underwent surgery because of spinal cord pathologies between September 2013 and January 2015. mATERIAl and mEThODS: We had twenty-six cases. Location of the lesions, surgery, neurological findings, and electrophysiological findings intraoperatively and postoperatively were documented. RESUlTS: The combination of motor evoked potential (MEP), somatosensorial evoked potential (SSEP), free-run and trigger electromyography (EMG) were performed according to lesion localization. MEPs plus SSEPs were run in 23 patients and MEPs with triggered EMG were performed in 4 patients. In only one patient, optimal recording could not be elicited because of technical problems. MEP and SSEP changes were recorded in 12 and 3 patients respectively. Postoperative neurological deficits were observed in 2 patients. Deficits were transient in one case and permanent in the other. While baseline MEP responses were either absent or low amplitude (<50 microvolt) in 7 patients, following resection they were either visible or increased in amplitude. Surgery was ended in one patient with C7-T2 intramedullary tumour after the right distal MEP response disappeared. CONClUSION: Multimodal IONM is an important method to monitor the neural structures under risk in spine surgery and to keep the surgery within safety limits, especially for intramedullary spinal cord lesion surgery.

🔖

Cite This Article

TAŞKIRAN, E., BRANDMEIER, S., OZEK, E., SARI, R., BÖLÜKBAŞI, F., ELMACI, İ. (2017). Multimodal Intraoperative Neurophysiological Monitoring in Spinal Cord Surgery. Turkish Neurosurgery, Cilt: 27 - Sayı: 3, 436–440. https://ajindex.com/articles/404578

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Campbell PG, Yadla S, Malone J, Zussman B, Maltenfort MG, Sharan AD, Harrop JS, Ratliff JK: Early complications related to approach in cervical spine surgery: Single-center prospective study. World Neurosurg 74:363-368, 2010 2. Feng B, Qiu G, Shen J, Zhang J, Tian Y, Li S, Zhao H, Zhao Y: Impact of multimodal intraoperative monitoring during surgery for spine deformity and potential risk factors for neurological monitoring changes. J Spinal Disord Tech 25:E108-114, 2012 3. Ghobrial GM, Williams KA Jr, Arnold P, Fehlings M, Harrop JS: Iatrogenic neurologic deficit after lumbar spine surgery: A review. Clin Neurol Neurosurg 139:76-80, 2015 4. Jankowska E, Padel Y, Tanaka R: Projections of pyramidal tract cells to alpha-motoneurones innervating hind-limb muscles in the monkey. J Physiol 249:637-667, 1975 5. Journee HL, Polak HE, de Kleuver M, Langeloo DD, Postma AA: Improved neuromonitoring during spinal surgery using double-train transcranial electrical stimulation. Med Biol Eng Comput 42:110-113, 2004 6. Journee HL, Polak HE, de Kleuver M: Conditioning stimulation techniques for enhancement of transcranially elicited evoked motor responses. Neurophysiol Clin 37:423-430, 2007 7. Kundnani VK, Zhu L, Tak H, Wong H: Multimodal intraoperative neuromonitoring in corrective surgery for adolescent idiopathic scoliosis: Evaluation of 354 consecutive cases. Indian J Orthop 44:64-72, 2010 8. Langeloo DD, Lelivelt A, Louis JH, Slappendel R, de Kleuver M: Transcranial electrical motor-evoked potential monitoring during surgery for spinal deformity: A study of 145 patients. Spine (Phila Pa 1976) 28:1043-1050, 2003 9. Macdonald DB, Skinner S, Shils J, Yingling C; American Society of Neurophysiological Monitoring: Intraoperative motor evoked potential monitoring -a position statement by the American Society of Neurophysiological Monitoring. Clin Neurophysiol 124(12):2291-2316, 2013 10. Malcharek MJ, Loeffler S, Schiefer D, Manceur MA, Sablotzki A, Gille J, Pilge S, Schneider G: Transcranial motor evoked potentials during anesthesia with desflurane versus propofol-A prospective randomized trial. Clin Neurophysiol 126(9):1825- 1832, 2015 11. McLaren AC, Bailey SI: Cauda equina syndrome: A complication of lumbar discectomy. Clin Orthop Relat Res 204:143-149, 1986 12. Mills KR: The basics of electromyography. J Neurol Neurosurg Psychiatry 76 Suppl 2:ii32-35, 2005 13. Nuwer MR, Emerson RG, Galloway G, Legatt AD, Lopez J, Minahan R, Yamada T, Goodin DS, Armon C, Chaudhry V, G