Journals / Turkish Neurosurgery / 2017 / Cilt: 27 - Sayı: 6

Tapered Flow Diverters in the Treatment of Intracranial Aneurysms

Pages
863–866
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

TFD may be preferred especially for arterial segments aneurysms where there is considerable discrepancy in size between the distal and proximal parent artery

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AIm: To report the initial experience of cerebral aneurysm treatment with Tapered flow diverters (TFDs). mATERIAl and mEThODS: Thirty patients with 34 aneurysms underwent cerebral aneurysm treatment with TFD (Silk, Balt, Montmorency, France) between March 2011 and March 2016.
📊
Key Findings & Data:RESUlTS: The patients’ mean age was 48±14.5 years (range, 16–74; 25 females).
💡
Conclusion & Impact:TFD may be preferred especially for arterial segments aneurysms where there is considerable discrepancy in size between the distal and proximal parent artery
🔬Design:Research Article
📍Scope:2011 Verileri
⚙️Variables:Domain Parameters

Özet

AIm: To report the initial experience of cerebral aneurysm treatment with Tapered flow diverters (TFDs). mATERIAl and mEThODS: Thirty patients with 34 aneurysms underwent cerebral aneurysm treatment with TFD (Silk, Balt, Montmorency, France) between March 2011 and March 2016. Procedural findings, complications, clinical and imaging follow-up were assessed retrospectively. RESUlTS: The patients’ mean age was 48±14.5 years (range, 16–74; 25 females). Aneurysms size ranged from 3 to 35 mm with an average diameter of 13.9±8.8 mm and a median diameter of 10.5 mm. Technical success rate was 96.6%. Technically, deployment of the device was similar to the non-tapered version and subjectively, it appeared to be easier in the paraophthalmic segment. Permanent morbidity and mortality rates secondary to the procedure were 0%. On clinical follow-up (29 patients, mean 9.3±9.1 months) there were no clinical untoward events. Imaging follow-up was at or after 6 months (20 patients, mean 12.3±10 months). Angiographic occlusion rate was 80%. CONClUSION: TFD is safe to use and effective for the treatment of intracranial aneurysms in this series. The occlusion rate is higher with respect to the previous reports and experience using the non-tapered version. Maintenance of porosity at the transition zone may be the factor underlying the higher occlusion rate. TFD may be preferred especially for arterial segments aneurysms where there is considerable discrepancy in size between the distal and proximal parent artery

🔖

Cite This Article

PEKER, A., AKGÜL, E., DAĞLIOĞLU, E., AKMANGİT, İ., KAYA, T., BELEN, A. D., ARAT, A. (2017). Tapered Flow Diverters in the Treatment of Intracranial Aneurysms. Turkish Neurosurgery, Cilt: 27 - Sayı: 6, 863–866. https://ajindex.com/articles/404547

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Arat YO, Arat A, Aydin K: Angiographic morphometry of internal carotid artery circulation in Turkish children. Turk Neurosurg 25: 608-616, 2015 2. Bing F, Darsaut TE, Salazkin I, Makoyeva A, Gevry G, Raymond J: Stents and flow diverters in the treatment of aneurysms: Device deformation in vivo may alter porosity and impact efficacy. Neuroradiology 55: 85-92, 2013 3. Buyukkaya R, Kocaeli H, Yildirim N, Cebeci H, Erdogan C, Hakyemez B: Treatment of complex intracranial aneurysms using flow-diverting silk stents. An analysis of 32 consecutive patients. Interv Neuroradiol 20:729-735, 2014 4. Daglioglu E, Akmangit I, Kahilogullari G, Derakhshani S, Belen D, Dede D, Arat A: Woven low-profile stent as an alternative to dual stenting in bifurcation aneurysms. Interv Neuroradiol 19 Suppl 2:157, 2013 5. Darsaut TE, Bing F, Makoyeva A, Gevry G, Salazkin I, Raymond J: Flow diversion of giant curved sidewall and bifurcation experimental aneurysms with very-low-porosity devices. World Neurosurg 82:1120-1126, 2014 6. Darsaut TE, Bing F, Salazkin I, Gevry G, Raymond J: Flow diverters can occlude aneurysms and preserve arterial branches: A new experimental model. AJNR Am J Neuroradiol 33:2004-2009, 2012 7. Darsaut TE, Bing F, Salazkin I, Gevry G, Raymond J: Flow diverters failing to occlude experimental bifurcation or curved sidewall aneurysms: An in vivo study in canines. J Neurosurg 117:37-44, 2012 8. Darsaut TE, Rayner-Hartley E, Makoyeva A, Salazkin I, Berthelet F, Raymond J: Aneurysm rupture after endovascular flow diversion: The possible role of persistent flows through the transition zone associated with device deformation. Interv Neuroradiol 19:180-185, 2013 9. Estrade L, Makoyeva A, Darsaut TE, Ghostine J, Kouznetsov E, Salazkin I, Roy D, Weill A, Raymond J: In vitro reproduction of device deformation leading to thrombotic complications and failure of flow diversion. Interv Neuroradiol 19:432-437, 2013 10. Gurkas E, Kaya T, Daglioglu E, Akmangit I, Belen D, Peker A, Dede D, Arat A: Silk device for the treatment of intracranial aneurysms. Part 1: Periprocedural results, technical aspects and learning curve. Turk Neurosurg 26(4):525-532, 2016 11. Kaya T, Daglioglu E, Gurkas E, Akmangit I, Peker A, Belen D, Dede D, Elhan A, Arat A: Silk device for the treatment of intracranial aneurysms. Part 2: Factors related to clinical and angiographic outcome. Turk Neurosurg 26(4):533-537, 2016 12. Lubicz B, Van der Elst O, Collignon L, Mine B, Alghamdi F: Silk flow-diverter