⚡ TL;DR(Too Long; Didn't Read)

Furthermore, using screws shorter than 28.46±3.60 mm doesn’t purchase the atlantoaxial joint

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AIM: In unique clinical situations where C1-C2 posterior fixation is not available or has previously failed, an anterior transarticular screw (ATAS) may be a viable alternative.
📊
Key Findings & Data:The aim of this study was to determine the morphometric characteristics C1-C2 vertebrae in order to perform anterior transarticular crossing screw fixation.
💡
Conclusion & Impact:Furthermore, using screws shorter than 28.46±3.60 mm doesn’t purchase the atlantoaxial joint
🔬Design:Research Article
📍Scope:2013 Verileri
⚙️Variables:Domain Parameters

Özet

AIM: In unique clinical situations where C1-C2 posterior fixation is not available or has previously failed, an anterior transarticular screw (ATAS) may be a viable alternative. However, there are no previous reports that investigate possible screw angles, screw entry points, and screw length based on computed tomography (CT) multiplanar reconstruction images in Turkish patients. The aim of this study was to determine the morphometric characteristics C1-C2 vertebrae in order to perform anterior transarticular crossing screw fixation. MATERIAL and METHODS: Patients who underwent a complete CT scan of the cervical spine for causes other than an investigation of cervical spine malformation or congenital anomaly between the years 2013 and 2015 were included in this study. The anterior transarticular C1-C2 screw angles, screw entry point, and screw length were measured on coronal and sagittal CT multiplanar reconstruction images. RESULTS: Twenty-five male and 14 female patients were included in the study. The mean maximum screw angle for ATAS was found to be 41.18°±4.49°. The minimum and maximum screw lengths were 27.46±3.39 mm and 28.46±3.60 mm, respectively. CONCLUSION: Preoperatively, performing a calculation of the possible screw angles, screw entry point, and screw length based on CT multiplanar reconstruction images for ATAS is a safe and applicable method. In cases in which ATAS fixation across the atlantoaxial joint procedure should be performed without performing a measurement, a screw angle not more than 41.18°±4.49° on the coronal plane does not damage the vertebral artery. Furthermore, using screws shorter than 28.46±3.60 mm doesn’t purchase the atlantoaxial joint

🔖

Cite This Article

TUN, K., CEMİL, B., GÖKÇE, E. C. (2018). Morphometric Characteristics of C1-C2 Vertebrae to Perform Anterior Transarticular Crossing Screw Fixation. Turkish Neurosurgery, Cilt: 28 - Sayı: 2, 270–274. https://ajindex.com/articles/404452

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Abou Madawi A, Solanki G, Casey AT, Crockard HA: Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg Br 79: 820-823, 1997 2. Aebi M: Surgical treatment of upper, middle and lower cervical injuries and non-unions by anterior procedures. Eur Spine J 19 Suppl 1: 33-39, 2010 3. Agrillo U, Mastronardi L: Acute combination fracture of atlas and axis: ‘‘triple’’ anterior screw fixation in a 92-year-old man: Technical note. Surg Neurol 65: 58-62, 2006 4. Apfelbaum RI, Lonser RR, Veres R, Casey A: Direct anterior screw fixation for recent and remote odontoid fractures. J Neurosurg 93 Suppl 2: 227-236, 2000 5. Barbour JR: Screw fixation and fractures of the odontoid process. S Aust Clin 5: 20-24 1971 6. Brooks AL, Jenkins EB: Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 60:279- 284, 1978 7. Coyne TJ, Fehlings MG, Wallace MC, Bernstein M, Tator CH: C1–C2 posterior cervical fusion: Long-term evaluation of results and efficacy. Neurosurgery 37:688-692, 1995 8. Du JY, Aichmair A, Kueper J, Wright T, Lebl DR: Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: A systematic review and meta-analysis. J Neurosurg Spine 22(2):151-161, 2015 9. Fried LC: Atlantoaxial fracture-dislocations. Failure of posterior C1 to C2 fusion. J Bone Joint Surg Br 55:490-496, 1973 10. Gallie WE: Fractures and dislocations of the cervical spine. Am J Surg 46: 495-499, 1939 11. Jeanneret B, Magerl F: Primary posterior fusion C1/2 in odontoid fractures: Indications, technique, and results of transarticular screw fixation. J Spinal Disord 5:464-475, 1992 12. Ji W, Zheng M, Tong J, Huang Z, Chen J, Qu D, Zhu Q: Feasibility and trajectory study of anterior transarticular crossing screw placement for atlantoaxial joint instability: A cadaveric study and description of a novel technique. Eur Spine J 24(12):2954-2960, 2015 13. Kim SM, Lim TJ, Paterno J, Hwang TJ, Lee KW, Balabhadra RS, Kim DH: Biomechanical comparison of anterior and posterior stabilization methods in atlantoaxial instability. J Neurosurg 100 Suppl Spine 3: 277-283, 2004 14. Koller H, Kammermeier V, Ulbricht D, Assuncao A, Karolus S, van den Berg B, Holz U: Anterior retropharyngeal fixation C1-C2 for stabilization of atlantoaxial instabilities: Study of feasibility, technical description and preliminary results. Eur Spine J 15:1326-1338, 2006 15. Li S, Ni B, Xie N, Wang M, Guo X, Zhang F, Wang J, Zh