Journals / Turkish Neurosurgery / 2019 / Cilt: 29 - Sayı: 1

A Novel Modular Dynamic Stabilization System for the Treatment of Degenerative Spinal Pathologies

Pages
115–120
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Italso proves to provide similar fusion with considerably less postoperative morbidity which makes it a better method to treat adultdegenerative spine diseases for carefully chosen patients.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AIM: To show the preliminary clinical results of the Orthrus modular dynamic stabilization system that is a new instrumentationsystem intended for degenerative diseases of the lumbar spine.MATERIAL and METHODS: The system utilizes two different types of screws that can be used in conjunction with different typesof rods such as titanium, carbon fiber or PEEK.
📊
Key Findings & Data:The second type of screw is a sliding screw to be used on a immovable vertebrae that allowsmovement in two planes on the tip.RESULTS: The system has been used on 36 patients with pathology varying from degenerative disc disease to degenerative lumbarscoliosis.
💡
Conclusion & Impact:Italso proves to provide similar fusion with considerably less postoperative morbidity which makes it a better method to treat adultdegenerative spine diseases for carefully chosen patients.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

AIM: To show the preliminary clinical results of the Orthrus modular dynamic stabilization system that is a new instrumentationsystem intended for degenerative diseases of the lumbar spine.MATERIAL and METHODS: The system utilizes two different types of screws that can be used in conjunction with different typesof rods such as titanium, carbon fiber or PEEK. The first type of screw is a double headed screw to interconnect to the upper andlower level with independent rods. The second type of screw is a sliding screw to be used on a immovable vertebrae that allowsmovement in two planes on the tip.RESULTS: The system has been used on 36 patients with pathology varying from degenerative disc disease to degenerative lumbarscoliosis. Satisfactory results have been obtained in a all 36 patients in the 12-month follow-up period.CONCLUSION: The Orthrus dynamic system shows better clinical results than the available dynamic systems on the market. Italso proves to provide similar fusion with considerably less postoperative morbidity which makes it a better method to treat adultdegenerative spine diseases for carefully chosen patients.

🔖

Cite This Article

OZER, A. F., CEVIK, O. M., ERBULUT, D. U., YAMAN, O., SENTURK, S., ÖKTENOĞLU, T., SASANİ, M., SÜZER, T., GOEL, V. (2019). A Novel Modular Dynamic Stabilization System for the Treatment of Degenerative Spinal Pathologies. Turkish Neurosurgery, Cilt: 29 - Sayı: 1, 115–120. https://ajindex.com/articles/404374

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Benzel EC: Biomechanics of spine stabilization. Thieme, 2011 2. Bono CM, Kadaba M, Vaccaro AR: Posterior pedicle fixationbased dynamic stabilization devices for the treatment of degenerative diseases of the lumbar spine. J Spinal Disord Tech 22(5):376-383, 2009 3. Bothmann M, Kast E, Boldt GJ, Oberle J: Dynesys fixation for lumbar spine degeneration. Neurosurg Rev 31(2):189- 196, 2008 4. Ciplak M, Suzer T, Senturk S, Yaman O, Sasani M, Oktenoglu T, Yilmaz A, Erbulut DU, Ozer AF: Complications of 2-level dynamic stabilization. Turk Neurosurg 2017 (Epub ahead of print) 5. Di Silvestre M, Lolli F, Bakaloudis G, Parisini P: Dynamic stabilization for degenerative lumbar scoliosis in elderly patients. Spine (Phila Pa 1976) 35(2):227-234, 2010 6. Erbulut DU, Kiapour A, Oktenoglu T, Ozer AF, GoelVK: A computational biomechanical investigation of posterior dynamic instrumentation: Combination of dynamic rod and hinged (dynamic) screw. J Biomech Eng 136(5):051007, 2014 7. Galbusera F, Volkheimer D, Reitmaier S, Berger-Roscher N, Kienle A, Wilke HJ: Pedicle screw loosening: A clinically relevant complication? Eur Spine J 24(5):1005-1016, 2015 8. Grob D, Benini A, Junge A, Mannion AF: Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: Surgical and patient-oriented outcome in 50 cases after an average of 2 years. Spine (Phila Pa 1976) 30(3):324- 331, 2005 9. Hoogland T, van den Brekel-Dijkstra K, Schubert M, Miklitz B: Endoscopic transforaminal discectomy for recurrent lumbar disc herniation: A prospective, cohort evaluation of 262 consecutive cases. Spine 33:973-978, 2008 10. Kaner T, Ozer AF: Dynamic stabilization for challenging lumbar degenerative diseases of the spine: A review of the literature. Adv Orthop 2013:753470, 2013 11. Kaner T, Sasani M, Oktenoglu T, Aydin AL, Ozer AF: Minimum two-year follow-up of cases with recurrent disc herniation treated with microdiscectomy and posterior dynamic transpedicular stabilisation. Open Orthop J 4:120-125, 2010 12. Kim CH, Chung CK, Jahng TA: Comparisons of outcomes after single or multilevel dynamic stabilization: Effects on adjacent segment. J Spinal Disord Tech 24(1):60-67, 2011 13. Ko CC, Tsai HW, Huang WC, Wu JC, Chen YC, Shih YH, Chen HC, Wu CL, Cheng H: Screw loosening in the Dynesys stabilization system: Radiographic evidence and effect on outcomes. Neurosurg Focus 28(6):E10, 2010 14. Lutz GE, Vad VB, Wisneski RJ: Fluoroscopic transforaminal lumbar epidural steroids: An outcome