Journals / Turkish Neurosurgery / 2020 / Cilt: 30 - Sayı: 4

Feasibility of Distal Mechanical Thrombectomy in M3, A3 and P3 Segments via a 0.013-inch Delivery System: Preliminary Experience

Pages
614–620
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The CVm stent retriever couldbecome a useful tool in DT based on its compatibility with a 0.013-inch lumen delivery system.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:ABSTRACTAIM: To assess the safety and efficacy of distal thrombectomy (DT) using a Catch View mini (CVm) device via a microcatheter witha 0.013-inch inner diameter.MATERIAL and METHODS: Nine of 246 acute ischemic stroke patients who underwent mechanical thrombectomy developeddistal emboli and were included in the study.
📊
Key Findings & Data:In all nine subjects (mean age, 64.5 ± 11.6; range, 39−77 years), a combination of CVmand a 0.013-inch microcatheter was used in distal mechanical thrombectomy.
💡
Conclusion & Impact:The CVm stent retriever couldbecome a useful tool in DT based on its compatibility with a 0.013-inch lumen delivery system.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

ABSTRACTAIM: To assess the safety and efficacy of distal thrombectomy (DT) using a Catch View mini (CVm) device via a microcatheter witha 0.013-inch inner diameter.MATERIAL and METHODS: Nine of 246 acute ischemic stroke patients who underwent mechanical thrombectomy developeddistal emboli and were included in the study. In all nine subjects (mean age, 64.5 ± 11.6; range, 39−77 years), a combination of CVmand a 0.013-inch microcatheter was used in distal mechanical thrombectomy. Modified Thrombolysis in Cerebral Ischemia scoresof 2c and 3 were considered to indicate successful recanalization, and patients with a Modified Rankin Score of ≤ 2 on the 90th daywere considered to have good clinical outcomes.RESULTS: Eleven DT maneuvers were performed using the same stent retriever and microcatheter. The mean National Institutes ofHealth Stroke Scale score was 13 ± 3.4. Thrombectomy was performed from M3 in six patients, A3 in four, and P3 in one. Successfulrecanalization was achieved in all of the procedures. The rate of good clinical outcome was 55.5%.CONCLUSION: Advances in technology in the endovascular field enable access to more distal vessels in acute ischemic stroke. Asthe profile of the instruments used during access decreases, the risk of complications may decrease. The CVm stent retriever couldbecome a useful tool in DT based on its compatibility with a 0.013-inch lumen delivery system.

🔖

Cite This Article

ÖNAL, Y., VELIOGLU, M., DEMİR, U., ÇELİKOĞLU, E., KARAKAŞ, H. M. (2020). Feasibility of Distal Mechanical Thrombectomy in M3, A3 and P3 Segments via a 0.013-inch Delivery System: Preliminary Experience. Turkish Neurosurgery, Cilt: 30 - Sayı: 4, 614–620. https://ajindex.com/articles/404319

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Berkhemer OA, Fransen PS, Beumer D, Van Den Berg LA, Lingsma HF, Yoo AJ, Schonewille WJ, Vos JA, Nederkoorn PJ, Wermer MJH, van Walderveen MA, Staals J, et al., for the MR CLEAN Investigators: A randomized trial of intraarterial treatment for acute ischemic stroke. N Engl J Med 372:11-20, 2015 2. Campbell BC, Mitchell PJ, Kleinig TJ, Dewey HM, Churilov L, Yassi N, Yan B, Dowling RJ, Parsons MW, Oxley TJ, Wu TY, Brooks M, Simpson MA, Miteff F, Levi CR, Krause M, Harrington TJ, Faulder KC, Steinfort BS, Priglinger M, Ang T, Scroop R, Barber PA, McGuinness B, Wijeratne T, Phan TG, Chong W, Chandra RV, Bladin CF, Badve M, Rice H, de Villiers L, Ma H, Desmond PM, Donnan GA, Davis SM, et al., for the Extend –IA Investigators: Endovascular therapy for ischemic stroke with perfusion-imaging selection. N Engl J Med 372:1009-1018, 2015 3. Costalat V, Lobotesis K, Machi P, Mourand I, Maldonado I, Heroum C, Vendrell JF, Milhaud D, Riquelme C, Bonafe A, Arquizan C: Prognostic factors related to clinical outcome following thrombectomy in ischemic stroke (RECOST study). 50 patients prospective study. Eur J Radiol 81:4075-4082, 2012 4. Del Zoppo GJ, Poeck K, Pessin MS, Wolpert SM, Furlan AJ, Ferbert A, Alberts MJ, Zivin JA, Wechsler L, Busse O, Greenlee R Jr, Brass L, Mohr JP, Feldmann E, Hacke W, Kase CS, Biller J, Gress D, Otis SM: Recombinant tissue plasminogen activator in acute thrombotic and embolic stroke. Annals of Neurology 32:78-86, 1992 5. Fischer ES: Die Lageabweichungen Der vorderen Hirnarterie Im Gefassbild. Munster: Zentralblatt Neurochirurgie, 1938 6. Gascou G, Lobotesis K, Machi P, Maldonado I, Vendrell JF, Riquelme C, Eker O, Mercier G, Mourand I, Arquizan C, Bonafe A, Costalat V: Stent retrievers in acute ischemic stroke: Complications and failures during the perioperative period. Am J Neuroradiol 35:734-740, 2014 7. Goyal M, Demchuk AM, Menon BK, Eesa M, Rempel JL, Thornton J, Roy D, Jovin TG, Willinsky RA, Sapkota BL, Dowlatshahi D, Frei DF, Kamal NR, Montanera WJ, Poppe AY, Ryckborst KJ, Silver FL, Shuaib A, Tampieri D, Williams D, Bang OY, Baxter BW, Burns PA, Choe H, Heo JH, Holmstedt CA, Jankowitz B, Kelly M, Linares G, Mandzia JL, Shankar J, Sohn SI, Swartz RH, Barber PA, Coutts SB, Smith EE, Morrish WF, Weill A, Subramaniam S, Mitha AP, Wong JH, Lowerison MW, Sajobi TT, Hill MD, et al., for the ESCAPE Trial Investigators: Randomized assessment of rapid endovascular treatment of ischemic stroke. N Engl J Med 372:1019-1030, 2015 8. Haussen DC,