Journals / Turkish Journal of Orthodontics / 2021 / Cilt: 34 - Sayı: 1

Effect of Low-Level Laser Therapy on Peri-Miniscrew Fluid Prostaglandin E2 and Substance P Levels: A Controlled Clinical Trial

Pages
26–30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Low-level laser therapy cannot be recommended as a clinical adjunct therapy to reduce inflammation and pain around the miniscrews

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: This study aims to evaluate the effect of low-level laser therapy on peri-miniscrew fluid prostaglandin E2 (PGE2) and sub- stance P (SP) levels during orthodontic treatment.
📊
Key Findings & Data:Methods: A total of 15 individuals were included in this study.
💡
Conclusion & Impact:Conclusion: Low-level laser therapy cannot be recommended as a clinical adjunct therapy to reduce inflammation and pain around the miniscrews
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: This study aims to evaluate the effect of low-level laser therapy on peri-miniscrew fluid prostaglandin E2 (PGE2) and sub- stance P (SP) levels during orthodontic treatment. Methods: A total of 15 individuals were included in this study. Miniscrews were inserted to the inter-radicular region of the maxillary right and left second premolar and the first molar teeth, and diode lasers were randomly applied to the right or left side. Irradiation was performed at 940 nm wavelength using a gallium-aluminum-arsenide diode laser with 100 mW power output, 0.125 cm2 spectral area, 8 J/cm2 energy density, and 10 seconds of exposure time. Peri-miniscrew fluid samples were collected on the 1st, 3rd, and 7th days, and PGE2 and SP levels were assessed. For statistical comparison, two-way (factors) analysis of variance with repeated measure- ments on one-factor levels was used at statistical significance (p) of <0.05. Results: PGE2 levels on the 1st, 3rd, and 7th days were 160.64±10.05, 135.17±37.18, and 98.57±22.94, respectively, in the control group and 150.75±9.08, 87.17±40.67, and 78.10±16.50, respectively, in the laser group. SP levels on the 1st, 3rd, and 7th days were 79.90±12.05, 64.61±10.05, and 70.05±9.10, respectively, in the control group and 76.32±11.39, 60.25±9.08, and 65.71±5.59, respec- tively, in the laser group. The differences in PGE2 and SP levels between the laser and control groups were not statistically significant at all time intervals. Conclusion: Low-level laser therapy cannot be recommended as a clinical adjunct therapy to reduce inflammation and pain around the miniscrews

🔖

Cite This Article

ALKAN, Ö., KAYA, Y., YÜKSEK, E., KÖMÜROGLU, A. U. (2021). Effect of Low-Level Laser Therapy on Peri-Miniscrew Fluid Prostaglandin E2 and Substance P Levels: A Controlled Clinical Trial. Turkish Journal of Orthodontics, Cilt: 34 - Sayı: 1, 26–30. https://ajindex.com/articles/403472

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (4)

  1. Schnelle MA, Beck FM, Jaynes RM, Huja SS. A Radiographic evalua- tion of the availability of bone for placement of miniscrews. Angle Orthod 2004; 74: 832-7
  2. Kuroda S, Sugawara Y, Deguchi T, Kyung HM, Takano-Yamamoto T. Clinical use of miniscrew implants as orthodontic anchorage: Suc- cess rates and postoperative discomfort. Am J Orthod Dentofacial Orthop 2007; 131: 9-15. [Crossref] 3. Bittencourt LP, Raymundo MV, Mucha JN. The optimal position for insertion of orthodontic miniscrews. Revista Odonto Ciência 2011; 26: 133-8
  3. Poggio PM, Incorvati C, Velo S, Carano A. ‘’Safe Zones’’: a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod 2006; 76: 191-7
  4. Goymen M, Isman E, Taner L, Kurkcu M. Histomorphometric evalua- tion of the effects of various diode lasers and force levels on ortho- dontic mini screw stability. Photomed Laser Surg 2015; 33: 29-34. [Crossref] 6. Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Takano-Ya- mamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Or- thod Dentofacial Orthop 2003; 124: 373-8. [Crossref] 7. Antoszewska J, Papadopoulos MA, Park HS, Ludwig B. Five-year experience with orthodontic miniscrew implants: a retrospective investigation of factors influencing success rates. Am J Orthod Den- tofacial Orthop 2009; 136: 158.E1-158.E10. [Crossref] 8. Osman A, Moneim AA, Harouni NE, Shokry M. Long-term evaluation of the effect of low-level laser therapy on orthodontic miniscrew stability and peri-implant gingival condition: A randomized clinical trial. J World Fed Orthod 2017; 6: 109-4. [Crossref] 9. Garcez AS, Suzuki SS, Martinez EF, Lemini MG, Suzuki H. Effects of low-intensity laser therapy over mini-implants success rate in pigs. Lasers Med Sci 2015; 30: 727-32. [Crossref] 10. Pinheiro AL. Advances and perspectives on tissue repair and heal - ing. Photomed Laser Surg 2009; 27: 833-6. [Crossref] 11. Flieger R, Gedrange T, Grzech Leśniak K, Dominiak M, Matys J. Low-level laser therapy with a 635 nm diodelaser affects orthodon- tic mini-implants stability. A randomized Clinical split-mouth trial. J Clin Med 2019; 9: 112-23. [Crossref] 12. Qamruddin I, Alam MK, Fida M, Khan AG. Effect of a single dose of low-level laser therapy on spontaneous and chewing pain caused by elastomeric separators. Am J Orthod Dentofacial Orthop 2016; 149: 62-6. [Crossref] 13. Almallah MME, Almahdi WH, Hajeer MY. Evaluation of low