Journals / Gıda / 2011 / Cilt: 36 - Sayı: 1

Examination of Changes in Certain Vitamins in Baby Foods by Capillary Electrophoresis (in English)

Bebek Mamalarında bazı Vitamin Değişimlerinin Kapiler Elektroforez ile İncelenmesi (İngilizce)

Journal
Gıda
Pages
1–8
Publication Date
2011-02-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Losses of mentioned vitamins were observed at the fifteenth-day for all samples

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This study describes the analysis of baby foods regarding time-dependent changes of d-pantothenate and niacin by a new capillary electrophoretic method at first and fifteenth days of opening the packages.
📊
Key Findings & Data:D-pantothenate amounts in eight of the samples were found to be higher than those identified in the Turkish Standard and it was not detected in the nine samples.
💡
Conclusion & Impact:Losses of mentioned vitamins were observed at the fifteenth-day for all samples
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Bebek maması · Kapiler elektroforez · D-pantetonat

Abstract

This study describes the analysis of baby foods regarding time-dependent changes of d-pantothenate and niacin by a new capillary electrophoretic method at first and fifteenth days of opening the packages. D-pantothenate amounts in eight of the samples were found to be higher than those identified in the Turkish Standard and it was not detected in the nine samples. Niacin was not detected in the seven samples. Losses of mentioned vitamins were observed at the fifteenth-day for all samples

Özet

Bu çalışma, bebek mamalarının paketin açıldığı birinci ve onbeşinci günlerdeki d-pantotenat ve niasinin değişiminin yeni bir kapiler elektroforetik yöntemle zamana bağımlı olarak değişimini tanıtmaktadır. Se­kiz numunede D-pantotenat miktarı Türk Standartlarının belirlediği değerlerden yüksek bulunmuş, dokuz numunede bulunmamıştır. Yedi numunede niasine rastlanmamıştır. On beşinci günde tüm numunelerde vitamin kayıbı gözlenmiştir.

🔖

Cite This Article

UYSAL, Ü. D., TUNÇEL, M., TUNCEL, N. B. (2011). Examination of Changes in Certain Vitamins in Baby Foods by Capillary Electrophoresis (in English). Gıda, Cilt: 36 - Sayı: 1, 1–8. https://ajindex.com/articles/39641

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Anon 1997. US Food and Drug administration (FDA). Overview of infant formulas. USA: Center for Food Safe ty and Applied Nutrition, Office of Special Nutritionals Bermejo P, Pena E, Dominguez R, Bermejo A, Fraga JM, Cocho JA. 2000. Speciation of iron in breast milk and infant formulas whey by size exclusion chromatog raphy-high performance liquid chromatography and electrothermal atomic absorption spectrometry. Talan ta, 50: 1211-1222.
  2. Rodriguez Rodriguez EM, Sanz Alaejos M, Diaz Romero C. 2000. Concentrations of iron, copper and zinc in human milk and powdered infant formula. Int J Food Sci Nutr, 51: 373-380.
  3. Ikem A, Nwankwoala A, Odueyungbo S, Nyavor K, Egiebor N. 2002. Levels of 26 elements in infant formula from USA, UK, and Nigeria by microwave digestion and ICP–OES. Food Chem, 77: 439-447 Combs Jr GF. 1992. Discovery of the vitamins. In: The vitamins: fundamental aspects in nutrition and health, Academic Press,
  4. San Diego, USA. Albalá-Hurtado S, Novella-Rodríguez S, VecianaNogués MT, Mariné-Font A. 1997. Determination of vitamins A and E in infant milk formulae by high-per formance liquid chromatography. J Chromatogr A, 778: 243-246 Albalá-Hurtado S, Veciana-Nogués MT, IzquierdoPulido M, Mariné-Font A. 1997. Determination of wa ter-soluble vitamins in infant milk by high-performance liquid chromatography. J Chromatogr A, 778: 247-253
  5. Gonzalez-Corbella MJ, Tortras-Biosca M, Castel lote-Bargallo AI, Lopez-Sabater MC. 1999. Retinol and α-tocopherol in infant formulas produced in the EEC. Food Chem, 66 (2): 221-226
  6. Majchrzak D, Elmadfa I. 2001. Phylloquinone (vitamin K1) content of commercially-available baby food prod ucts. Food Chem, 74: 275-280.
  7. Rodrigo N, Alegría A, Barberá R, Farré R. 2002. High-performance liquid chromatographic determina tion of tocopherols in infant formulas. J Chromatogr A, 947: 97-102
  8. Mendoza BR, Morera Pons S, Castellote Bargalló AI, López-Sabater MC. 2003. Rapid determination by re versed-phase high-performance liquid chromatography of vitamins A and E in infant formulas. J Chromatogr A, 1018: 197-202.
  9. Vinas P, Lopez-Erroz C, Balsalobre N, HernandezCordoba M. 2003. Reversed-phase liquid chromatogra phy on an amide stationary phase for the determination of the B group vitamins in baby foods. J Chromatogr A, 1007: 77-84
  10. Perales S, Delgado MM, Alegría A, Barberá R, Farré R. 2005. Liquid chromatographic determination of Vita min D3 in infant formulas and fortified milk. Anal Chim Acta, 543: 58-63. Chávez-Servín JL, Castellote A, Ló