Development of PVC membrane potentiometric sensor for the determination of potassium ion and its applications

Potasyum iyonunun tayini için PVC membran potansiyometrik sensör geliştirilmesi ve uygulamaları

Pages
851–855
Publication Date
2021-12-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Finally, the developed potassium selective sensor was successfully used in the determination of potassium in tap water and a drug sample.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a novel all-solid-state contact poly(vinylchloride) (PVC) membrane potassium selective sensor with a pyrazole derivative molecule as an ionophore has been developed.
📊
Key Findings & Data:The potassium selective sensor has a composition of PVC, ionophore, anion excluder (potassium tetrakis (p-chlorophenyl)borat (KTpClPB)) and plasticizer (bis(2- ethylhexyl)adipate (DEHA)) in the ratio of 32.0:4.0:1.0:63.0 (mg).
💡
Conclusion & Impact:Finally, the developed potassium selective sensor was successfully used in the determination of potassium in tap water and a drug sample.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:potasyum · PVC membran · Potansiyometri

Abstract

In this study, a novel all-solid-state contact poly(vinylchloride) (PVC) membrane potassium selective sensor with a pyrazole derivative molecule as an ionophore has been developed. The potassium selective sensor has a composition of PVC, ionophore, anion excluder (potassium tetrakis (p-chlorophenyl)borat (KTpClPB)) and plasticizer (bis(2- ethylhexyl)adipate (DEHA)) in the ratio of 32.0:4.0:1.0:63.0 (mg). The potassium selective sensor works in a linear concentration range of 1.0×10-5 to 1.0×10-1 M with a low detection limit of 6.02 × 10−6 M The developed potassium selective sensor works in pH range of 6.0-10.0 and has good repeatability, selectivity and a short response time of 10 seconds. Finally, the developed potassium selective sensor was successfully used in the determination of potassium in tap water and a drug sample.

Özet

kullanıldığı yeni tümüyle katı hal kontak poli(vinilklorür) (PVC) membran potasyum sensörü geliştirildi. Potasyum seçici sensör PVC, iyonofor, potasyum tetrakis (p-klorofenil)borat (KTpClPB)) ve plastikleştirici (bis (2-etilheksil)adipat (DEHA))’ın 32.0:4.0:1.0:63.0 (mg)’lık bileşimine sahiptir. Geliştirilen potasyum seçici sensör, 6.02×10- 6 M’lık düşük algılama limiti ile 1.0×10-5 -1.0×10-1 M konsantrasyon aralığında doğrusal olarak çalışmaktadır. Geliştirilen potasyum seçici sensör pH 6.0-10.0 aralığında çalışmaktadır, iyi tekrarlanabilirlik, iyi seçicilik ve 10 saniyelik kısa cevap zamanına sahiptir. Son olarak, geliştirilen potasyum seçici sensör musluk suyu ve ilaç örneğinde potasyum tayininde başarıyla kullanılmıştır

🔖

Cite This Article

IŞILDAK, Ö., ÖZBEK, O., GÜRDERE, M. B., ÇETİN, A. (2021). Development of PVC membrane potentiometric sensor for the determination of potassium ion and its applications. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, Cilt: 27 - Sayı: 7, 851–855. https://ajindex.com/articles/394884

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Abedi MR, Zamani HA. “Barium(II)-PVC membrane sensor based on 4-4′-methylenediantipyrine as a neutral carrier”. Analytical Letters, 41(12), 2251-2266, 2008
  2. Shamsipur M, Soleymanpouri A, Akhond M, Sharghib H. “New macrocyclic diamides as neutral ionophores for highly selective and sensitive PVC-membrane electrodes for Be2+ ion”. Electroanalysis, 16(4), 282-288, 2004
  3. Kanberoglu GS, Coldur F, Topcu C, Cubuk O. “PVCmembrane potentiometric sensor for the determination of Tamoxifen in pharmaceutical formulations”. IEEE Sensors Journal, 15(11), 6199-6207, 2015
  4. Isildak O, Deligönül N, Özbek O. “A novel silver (I)- selective PVC membrane sensor and its potentiometric aplications”. Turkish Journal of Chemistry, 43(4), 1149- 1158, 2019
  5. Gupta VK, Goyal RN, Al-Khayat MA, Kumar P, Bachheti, N. “A new Zn(II)-selective potentiometric sensor based on 4- tert-butylcalix[4]arene in PVC matrix”. Talanta, 69(5), 1149-1155, 2006
  6. Ding L, Ding J, Ding B, Qin W “Solid-Contact potentiometric sensor for the determination of total ammonia nitrogen in seawater”. Interational Journal of Electrochemistry Science, 12(4), 3296-3308, 2017
  7. Rezaei B, Hadadzadeh H, Azimi A. “Nickel(II) Selective PVC-based membrane sensor using a schiff base”. International Journal of Spectroscopy, 1-7, 2011
  8. Isildak O, Özbek O. “Application of potentiometric sensors in real samples”. Critical Reviews in Analytical Chemistry, 51(3), 218-231, 2021
  9. Holliday MA, Segar WE, Bright NH, Egan T. “The effect of potassium deficiency on the kidney”. Pediatrics, 26, 950-959, 1960
  10. Weaver CN. “Potassium and health”. Advances in Nutrition, 4(3), 368-377, 2013
  11. Yu BS, Nie LH, Yao SZ. “Ion chromatographic study of sodium, potassium and ammonium in human body fluids with bulk acoustic wave detection”. Journal of Chromatography B: Biomedical Sciences and Applications, 693(1), 43-49, 1997
  12. Lima AS, Bocchi N, Gomes HM, Teixeira MFS. “An electrochemical sensor based on nanostructured hollandite-type manganese oxide for detection of potassium ıons”. Sensors, 9(9), 6613-6625, 2009
  13. Yu K, He N, Kumar N, Wang N, Bobacka J, Ivaska A. “Electrosynthesized polypyrrole/zeolite composites as solid contact in potassium ion-selective electrode”. Electrochimica Acta, 228(40), 66-75, 2017
  14. Bladh E, Gedda O. “A new method for determination of potassium in serum”. Scandinavian Journal of Clinical and Laboratory Investigation, 12(3), 274-276, 1960
  15. Doku GN, Gadzekpo VPY. “Sim