The number of trapped electrons, activation energies and frequency factor for individual glow peaks are as follows: (Peak 1) $3x10^{13}$, 1.27 and $2.13x10^{17}$, (Peak 2) $6.3x10^{13}$, 1.01 and $9.2x10^{12}$, (Peak 3) $3.3x10^{14}$, 0.7 and $6.12x10^7$, (Peak 4) $2.4x10^14$, 1.14 and $3.28x10^12$, (Peak 5) $1.5x10^14$, 0.84 and $2.56x10^8$, (Peak 6) $2.4x10^{14}$, 0.98 and $1.76x10^9$.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Computerized glow curve deconvolution method is used to determine the number of peaks, the order of kinetics b, the activation energy $E_a$,frequency factor s and number of the trapped electrons n0 associated with the glow peaks in single crystal of $CaF_2$:Dy (TLD-200).
📊
Key Findings & Data:Glow curve analysis indicate that the glow curve in the temperature region between room temperature and 250 $\circ$C can be best described as a superposition of six peaks.
💡
Conclusion & Impact:The number of trapped electrons, activation energies and frequency factor for individual glow peaks are as follows: (Peak 1) $3x10^{13}$, 1.27 and $2.13x10^{17}$, (Peak 2) $6.3x10^{13}$, 1.01 and $9.2x10^{12}$, (Peak 3) $3.3x10^{14}$, 0.7 and $6.12x10^7$, (Peak 4) $2.4x10^14$, 1.14 and $3.28x10^12$, (Peak 5) $1.5x10^14$, 0.84 and $2.56x10^8$, (Peak 6) $2.4x10^{14}$, 0.98 and $1.76x10^9$.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Computerized glow curve deconvolution method is used to determine the number of peaks, the order of kinetics b, the activation energy $E_a$,frequency factor s and number of the trapped electrons n0 associated with the glow peaks in single crystal of $CaF_2$:Dy (TLD-200). Glow curve analysis indicate that the glow curve in the temperature region between room temperature and 250 $\circ$C can be best described as a superposition of six peaks. First five peaks are described by first-order kinetics and sixth peak general-order kinetic. The number of trapped electrons, activation energies and frequency factor for individual glow peaks are as follows: (Peak 1) $3x10^{13}$, 1.27 and $2.13x10^{17}$, (Peak 2) $6.3x10^{13}$, 1.01 and $9.2x10^{12}$, (Peak 3) $3.3x10^{14}$, 0.7 and $6.12x10^7$, (Peak 4) $2.4x10^14$, 1.14 and $3.28x10^12$, (Peak 5) $1.5x10^14$, 0.84 and $2.56x10^8$, (Peak 6) $2.4x10^{14}$, 0.98 and $1.76x10^9$.

🔖

Cite This Article

YAZICI, A. N., HACIİBRAHİMOĞLU, M. Y. (2001). Determination of the trapping parameters of glow peaks of CaF2:Dy (TLD-200) by using computer glow curve deconvolution method. Turkish Journal of Physics, Cilt: 25 - Sayı: 3, 249–255. https://ajindex.com/articles/378648

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (19)

  1. Becker K., Solid State Dosimetry, CRC Press, (1973) p.65
  2. Bacci C, Draghi V., Furetta C. and Rispoli B., IEEE Transactions on Nuclear Science, 36(1989) 1154
  3. Jain V.K., Radiat.Appl.Instrum.Part C\ 36 (1990) 47
  4. Randall J.T. and Wilkins M.H.F., Proc.R.Soc.A., A184 (1945) 366
  5. Garlick G.F.J. and Gibson A.F., Proc.Phys.Soc, 60 (1948) 574
  6. May C.E. and Patridge J.A., J.Chem.Phys., 40 (1964) 1401
  7. Chen R., Journal of Applied Physics, 40 (1969) 570
  8. Bull R.K., McKeever S.W.S., Chen R., Mathur V.K., Rhodes J.F. and Brown M.D.,J.Phys.D.-Appl.Phys., 19 (1986) 1321
  9. Chen R. and Winer A., Journal of Applied Physics, 41 (1970) 5227
  10. Halperin A. and Braner A.A., Phys.Rev., 117 (1960) 405
  11. Bos A.J.J., Piters T.M., Gomez Ros J.M. and Delgado A., GLOCANIN an Intercomparision of Glow Curves Analysis Computer Programs, IRI-CIEMAT Report 131-93-005 (IRI, Delft)
  12. Pradhan A.S. and Rassow J., Nucl.Instrum.Methods, A255 (1987) 234
  13. Ben Shachar B. and Horowitz Y.S., J.Phys.D:Appl.Phys., 24 (1991) 1649
  14. Horowitz Y.S. and Moscovitch M., Nucl.Instrum.Methods, A243 (1986) 207
  15. Horowitz Y.S., Moscovitch M. and Wilt M. Nucl.Instrum.Methods, A244 (1986) 556
  16. Bacci C, Bernardini P., Di Domenico A., Furetta C. and Rispoli B., Nucl.Instrum. Methods,A286 (1986) 295
  17. Yossian D. and Horowitz Y.S., J.Phys.D:Appl.Phys., 28 (1995) 1495
  18. Sakuria T. and Gartia R.K., J.Phys.D:Appl.Phys., 29 (1996) 2714
  19. Yazıcı A.N. Radiation Protection Dosimetry, 80(4) (1998) 273.