Journals / Turkish Journal of Physics / 2009 / Cilt: 33 - Sayı: 6

Measurements of K-shell fluorescence yields for Ti, V, Cr, Fe, Co, Ni and Cu elements and their halogen compounds

Pages
311–316
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Measurement of K-shell fluorescence yields wK for these elements are compared with earlier experimental results obtained by other methods.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:K-shell fluorescence yields wK were measured for the elements Ti, V, Cr, Fe, Co, Ni, Cu and F and Cl compounds of these elements.
📊
Key Findings & Data:Measurements were carried out at 10 keV excitation energy using secondary excitation method.
💡
Conclusion & Impact:Measurement of K-shell fluorescence yields wK for these elements are compared with earlier experimental results obtained by other methods.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:X-ray · Fluorescence yield · Halogen compounds.

Abstract

K-shell fluorescence yields wK were measured for the elements Ti, V, Cr, Fe, Co, Ni, Cu and F and Cl compounds of these elements. Measurements were carried out at 10 keV excitation energy using secondary excitation method. K x-rays emitted by samples were counted by a Si(Li) detector with 160 eV resolution at 5.9 keV. Measurement of K-shell fluorescence yields wK for these elements are compared with earlier experimental results obtained by other methods.

Özet

K-shell fluorescence yields wK were measured for the elements Ti, V, Cr, Fe, Co, Ni, Cu and F and Cl compounds of these elements. Measurements were carried out at 10 keV excitation energy using secondary excitation method. K x-rays emitted by samples were counted by a Si(Li) detector with 160 eV resolution at 5.9 keV. Measurement of K-shell fluorescence yields wK for these elements are compared with earlier experimental results obtained by other methods.

🔖

Cite This Article

BAYDAŞ, E., ÖZ, E. O., BÜYÜKYILDIZ, M. (2009). Measurements of K-shell fluorescence yields for Ti, V, Cr, Fe, Co, Ni and Cu elements and their halogen compounds. Turkish Journal of Physics, Cilt: 33 - Sayı: 6, 311–316. https://ajindex.com/articles/378064

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. W. Bambynek, B. Crasemann, R. W. Fink, H. U. Freund, H. Mark, C. D. Swift, R. E. Price and P. V. Rao, Rev. Mod. Phys., 44, (1972), 716. J. H. Hubbell, P. H. Trehan, N. Singh, B. Chand, D. Mehta, M. L. Garg, R. Garg, S. Singh and S. Puri, J. Phys. Chem. Ref. Data., 23, (1994), 339. Ö. Şimşek, 0. Doğan, Ü. Turgut and M. Ertuğrul, Radiat. Phys. Chem., 58, (2002), 207. E. McGuire, J. Phys. Rev., 185, (1970),1. E. McGuire, J. Phys. Rev. A., 24, (1970), 273. D. L. Walters and C. P. Bhalla, Phys. Rev., A3, (1971), 1919.
  2. R. Durak and Y. Özdemir, Radiat. Phys. Chem., 61, (2001), 19. R. Durak, Physiea Seripta, 58, (1998), 111. R. Durak and Y. Şahin, Phys. Rev. A., 57, (1998), 2578. C. Söğüt, E. Baydaş and E. Büyükkasap, J. Tmee Mieroprobe Teehn., 173, (1999), 285. Ö. Söğüt, E. Baydaş, E. Büyükkasap, Y. Şahin and A. Küçükönder, J. Radioanal. Nuel. Chem., 25 1, (2002), 119. E. Storm, I. Israel, Nucl. Data Tables, A7, (1970), 565. J. H. Scofield, Report UCRL 51326, Lawrence Livemore Lab., Liverrnore, CA (1973).
  3. M. Ö. Krause, J. Phys. Chem. Ref. Data., 8, (1979), 307. J. H. Scofield, Atom. Data Nucl. Data Tables, 14, (1974), 121. M. L. Garg, S. Kumar, D. Mehta, H. R. Verma, P. C. Mengal and P. N. Trehan, J. Phys. B: At. Mol. Phys, 18, (1985), 4529. C. Bhan, S. N. Chaturvedi and N. Nath, X—Ray Spectram., 15, (1986), 217. S. Singh, D. Mehta, M. L. Garg, S. Kumar, N. Singh, P. C. Mangal and P. N. Trehan, J. Phys. B: At. Mol. Phys,, (1987), 3325. J. H. Hubbell and M. S. Seltzer, National Institute of Standards and Technology Report No. NISTIR, (1995), 5632. R. C. Weast, Handbook of Chemistry and Physics, CRC Press. (1985—1986)