Journals / Turkish Journal of Physics / 2017 / Cilt: 41 - Sayı: 1

Monitoring Akkuyu nuclear reactor using antineutrino ux measurement

Pages
41–46
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It was found that the bottom (or top) face of the target should be instrumented by six 10-inch-diameter photomultiplier tubes with photon detection efficiency of about 35% and the optimum Gd concentration was found to be about 0.3%{0.5%.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:We present a simulation-based study for monitoring Akkuyu nuclear power plant\'s activity using antineutrino ux originating from the reactor core.
📊
Key Findings & Data:A gadolinium-doped water Cherenkov detector was designed and optimization studies were performed using the Geant4 simulation toolkit.
💡
Conclusion & Impact:It was found that the bottom (or top) face of the target should be instrumented by six 10-inch-diameter photomultiplier tubes with photon detection efficiency of about 35% and the optimum Gd concentration was found to be about 0.3%{0.5%.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

We present a simulation-based study for monitoring Akkuyu nuclear power plant\'s activity using antineutrino ux originating from the reactor core. A gadolinium-doped water Cherenkov detector was designed and optimization studies were performed using the Geant4 simulation toolkit. It was found that the bottom (or top) face of the target should be instrumented by six 10-inch-diameter photomultiplier tubes with photon detection efficiency of about 35% and the optimum Gd concentration was found to be about 0.3%{0.5%. The rst study on the design of a monitoring detector facility for Akkuyu nuclear power plant is discussed in this paper.

🔖

Cite This Article

ÖZTÜRK, S., ADIGÜZEL, A., ÖZCAN, V. E., ÜNEL, N. G. (2017). Monitoring Akkuyu nuclear reactor using antineutrino ux measurement. Turkish Journal of Physics, Cilt: 41 - Sayı: 1, 41–46. https://ajindex.com/articles/377881

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (6)

  1. Korovkin, V. A; Kodanev, S. A.; Panashchenko, N. S.; Sokolov, D. A.; Solov\'yanov, O. M.; Tverdovskii, N. D.; Yarichin, A. D.; Ketov, S. N; Kopeikin, V. I.; Machulin, I. N.; et al. Atomic Energy 1988, 65, 712-718
  2. Huber, P. Phys. Rev. C 2011, 84, 024617
  3. Mueller, Th. A.; Lhuillier, D.; Fallot, M.; Letourneau, A.; Cormon, S.; Fechner, M.; Giot, L.; Lasserre, T.; Martino, J.; Mention, G.; et al. Phys. Rev. C 2011, 83, 054615
  4. Anjos, J. C.; Abrahao, T.; Alvarenga, T. A.; Andrade, L. P.; Azzi, G.; Cerqueira, A. S., Chimenti, P.; Costa, J. A.; Dornelas, T. I; Farias, P. C. M. A; et al. Nuclear and Particle Physics Proceeding 2015, 267-269, 108-115 [5] International Atomic Energy Agency (IAEA) Final Report: Focused Workshop on Antineutrino Detection for Safeguards Applications, 2008
  5. Bahcall, J. N.; Pinsonneault, H. Phys. Rev. Lett. 2004, 92, 121301
  6. Agostinell, S.; Allison, J.; Amako, K.; Apostolakis, J.; Araujo, H.; Arce, P.; Asai, M.; Axen, D.; Banerjee, S.; Barrand G.; et al. Instruments and Methods in Physics Research A 2003, 506, 250-303