Journals / Turkish Journal of Anaesthesiology and Reanimation / 2018 / Cilt: 46 - Sayı: 1

Servikal Omurga Hareketi: LMA CTrach, C-MAC Videolaringoskop ve Macintosh Laringoskopun Floroskopik Karşılaştırması

Fluoroscopic Comparison of Cervical Spine Motion Using LMA CTrach, C-MAC Videolaryngoscope and Macintosh Laryngoscope

Pages
44–50
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Sonuç: Entübasyon sırasında LMA CTrach, Macintosh ve C-MAC videolaringoskoptan daha az servikal omurga hareketine neden olduğundan; servikal travmalı hastalarda daha uygun bir seçenek olabilir.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Servikal omurga hasarından şüphelenildiğinde endotrakeal entübasyon dikkatli yapılmalıdır.
📊
Key Findings & Data:Bu çalışmanın amacı LMA (Laryngeal Mask Airway) CTrach, C-MAC Videolaringoskop ve Macintosh Laringoskop ile entübasyon sırasında floroskopi ile servikal omurga hareketini değerlendirmektir.
💡
Conclusion & Impact:Sonuç: Entübasyon sırasında LMA CTrach, Macintosh ve C-MAC videolaringoskoptan daha az servikal omurga hareketine neden olduğundan; servikal travmalı hastalarda daha uygun bir seçenek olabilir.
🔬Design:Modeling & Simulation
📍Scope:22 hasta
⚙️Variables:Domain Parameters

Abstract

Amaç: Servikal omurga hasarından şüphelenildiğinde endotrakeal entübasyon dikkatli yapılmalıdır. Bu çalışmanın amacı LMA (Laryngeal Mask Airway) CTrach, C-MAC Videolaringoskop ve Macintosh Laringoskop ile entübasyon sırasında floroskopi ile servikal omurga hareketini değerlendirmektir. Yöntemler: Bu tek merkezli, prospektif, gözlemsel kontrollü bir çalışmaydı. Çalışmaya 18-65 yaşları arasında genel anestezi altında operasyon uygulanan 22 hasta dahil edildi. Endotrakeal entübasyondan önce, hastanın başı nötr konumda iken servikal omurga floroskopi görüntüleri elde edildi. Tüm hastalarda standart Macintosh laringoskop, LMA CTrach ve C-MAC Videolaringoskop kullanıldı. Laringoskopi simülasyonları sırasında servikal omurgadaki değişikliklerin floroskopik görüntüleri elde edildi. Tüm hastalar son laringoskopi sırasında C-MAC kullanılarak entübe edildi. Floroskopi görüntüleri üzerinde C0 C1, C0 C2, C0 C3, C0 C4, C1 C2 ve C2 C3 arasındaki Atlantooksipital mesafeler ve açılar ölçüldü ve aradaki farklar cihazlar arasında karşılaştırıldı. Bulgular: Ortalama Atlantooksipital mesafe, nötral pozisyonda 20,4 mm ölçüldü ve sırasıyla Macintosh laringoskop, LMA CTrach ve C-MAC Videolaryngoscope'ın yerleştirilmesinden sonra 13,1, 17,2 ve 12,3'e düştü ve aradaki farklar anlamlıydı (p<0,001). C0 C2, C0 C3 and C1 C2 açılarında üç cihazın yerleştirilmesi ile de nötral pozisyona göre anlamlı fark vardı (p<0,001). LMA Ctrach C0 C2, C0 C3 and C0C4 açılarında Macintosh laringoskop ve C-MAC Videolaringoskop ile karşılaştırıldığında servikal omurgada anlamlı olarak az harekete neden oldu (p<0,001). Sonuç: Entübasyon sırasında LMA CTrach, Macintosh ve C-MAC videolaringoskoptan daha az servikal omurga hareketine neden olduğundan; servikal travmalı hastalarda daha uygun bir seçenek olabilir.

Özet

Objective: Endotracheal intubation should be performed with care when cervical spine (C-spine) injury is suspected. The aim of this study was to evaluate the movement of the C-spine using fluoroscopy during intubation with Laryngeal Mask Airway (LMA) CTrach, C-MAC videolaryngoscope and Macintosh laryngoscope. Methods: This was a single-centre, prospective, observational, controlled trial. In total, 22 surgical patients aged 18-65 years planned to undergo operation under general anaesthesia, were enrolled. X-ray images of the C-spine were obtained using fluoroscopy with the patients’ head in a neutral position. All patients underwent laryngoscopy using a Macintosh blade, LMA CTrach and C-MAC videolaryngoscope, and fluoroscopic images of the C-spine were obtained. All the patients were intubated at the last laryngoscopy simulation (using the C-MAC). The atlanto-occipital distance (AOD) and angles between C0C1, C0C2, C0C3, C0C4, C1C2 and C2C3 lines were measured and compared between each device. Results: The mean AOD was measured as 20.4 mm in a neutral position, which decreased to 13.1, 17.2 and 12.3 mm after the insertion of the Macintosh laryngoscope, LMA CTrach and C-MAC videolaryngoscope, respectively. The differences were significant (p<0.001). Moreover, significant difference was noted in C0C2, C0C3 and C1C2 angles with the insertion of the three devices (p<0.001). The LMA CTrach resulted in significantly lesser C-spine movements in C0C2, C0C3 and C0C4 angles compared to the Macintosh laryngoscope and C-MAC videolaryngoscope (p<0.001). Conclusion: The LMA CTrach resulted in lesser C-spine movements compared to Macintosh laryngoscope and C-MAC videolaryngoscope. In case of the C-spine injury, LMA CTrach may be preferred and may cause fewer traumas during endotracheal intubation.

🔖

Cite This Article

ŞAHİN, T., AYDIN, Z. İ. A., AKANSEL, G., BALABAN, O., BERK, D., SOLAK, M., TOKER, K. (2018). Servikal Omurga Hareketi: LMA CTrach, C-MAC Videolaringoskop ve Macintosh Laringoskopun Floroskopik Karşılaştırması. Turkish Journal of Anaesthesiology and Reanimation, Cilt: 46 - Sayı: 1, 44–50. https://ajindex.com/articles/370571

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Hastings RH, Marks JD. Airway management for trauma patients with potential cervical spine injuries. Anesth Analg 1991
  2. [CrossRef] Ball PA. Critical care of spinal cord injury. Spine (Phila Pa 1976) 2001
  3. [CrossRef] Ghafoor AU, Martin TW, Gopalakrishnan S, Viswamitra S. Caring for the patients with cervical spine injuries: what have we learned? J Clin Anesth 2005
  4. [CrossRef] Liu EH, Goy RW, Chen FG. The LMA CTrach, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients. Br J Anaesth 2006
  5. [CrossRef] Tripathi DC, Jha PS, Trivedi LP, Doshi SM, Modia B. LMA C Trach aided endotracheal intubation in simulated cases of cervical spine injury: A series of 30 cases. Saudi J Anaesth 2013
  6. [CrossRef] Rudolph C, Schneider JP, Wallenborn J, Schaffranietz L. Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fiberscope and the Macintosh laryngoscope. Anaesthesia 2005
  7. [CrossRef] McElwain J, Laffey JG. Comparison of the C‐MAC, Airtraq and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization. Br J Anaesth 2011
  8. [CrossRef] Wong DM, Prabhu A, Chakraborty S, Tan G, Massicotte EM, Cooper R. Cervical spine motion during flexible bronchoscopy compared with the Lo-Pro GlideScope. Br J Anaesth 2009
  9. [CrossRef] Brimacombe J, Keller C, Kunzel KH, Gaber O, Boehler M, Puhringer F. Cervical spine motion during airway management: a cinefluoroscopic study of posteriorly destabilized third cervical vertebrae in human cadavers. Anesth Analg 2000
  10. [CrossRef] Houde BJ, Williams SR, Cadrin-Chenevert A, Guilbert F, Drolet P. A comparison cervical spine motion during orotracheal intubation with the Trachlight or the flexible fiberoptic bronchoscope. Anesth Analg 2009
  11. [CrossRef] Urakami Y, Takenaka I, Nakamura M, Fukuyama H, Aoyama K, Kadoya T. The reliability of the Bellhouse test for evaluating extension capacity of the occipitoatlantoaxial complex. Anesth Analg 2002
  12. [CrossRef] LeGrand SA, Hindman BJ, Dexter F, Weeks JB, Todd MM. Craniocervical motion during direct laryngoscopy and orotracheal intubation with the Macintosh and Miller blades: an in vivo cinefluoroscopic study. Anesthesiology 2007
  13. [CrossRef] Turkstra TP, Craen RA, Pelz DM, Gelb AW. Cervical spine motion: a fluoroscopic comparison during intubatio