Journals / Turkish Journal of Anaesthesiology and Reanimation / 2018 / Cilt: 46 - Sayı: 6

A Pilot Project Using Eye-Tracking Technology to Design a Standardised Anaesthesia Workspace

Pages
411–415
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Because eye tracking can provide objective data to influence the design process, it may beuseful when developing standardised anaesthesia workspace templates for individual practices.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Maximising safe handoff procedures ensures patient safety.
📊
Key Findings & Data:The design process should incorporate end user feedback and objectivedata.Methods: This pilot project aims to design a standardised anaesthesia workspace using eye-tracking technology at a single university-affiliatedVeterans Affairs hospital.
💡
Conclusion & Impact:Because eye tracking can provide objective data to influence the design process, it may beuseful when developing standardised anaesthesia workspace templates for individual practices.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: Maximising safe handoff procedures ensures patient safety. Anaesthesiology practices have primarily focused on developingbetter communication tools. However, these tools tend to ignore the physical layout of the anaesthesia workspace itself. Standardising theanaesthesia workspace has the potential to improve patient safety. The design process should incorporate end user feedback and objectivedata.Methods: This pilot project aims to design a standardised anaesthesia workspace using eye-tracking technology at a single university-affiliatedVeterans Affairs hospital. Twelve practising anaesthesiologists observed a series of images representing five clinical scenarios. Eachof these had a question prompting them to look for certain items commonly found in the anaesthesia workspace. Using eye-trackingtechnology, the gaze data of participants were recorded. These data were used to generate heat maps of the specific areas of interest in theworkspace that received the most fixation counts.Results: The laryngoscope and propofol had the highest percentages of gaze fixations on the left-hand side of the workstation, in closestproximity to the anaesthesiologist. Atropine, although the highest percentage of gaze fixations (33%) placed it on the right-hand side ofthe workstation, also had 25% of gaze fixations centred over the anaesthesia cart.Conclusion: Gaze fixation analyses showed that anaesthesiologists identified locations for the laryngoscope and propofol within easyreach and emergency medications further away. Because eye tracking can provide objective data to influence the design process, it may beuseful when developing standardised anaesthesia workspace templates for individual practices.

🔖

Cite This Article

HANHAN, J., KING, R., HARRISON, T. K., KOU, A., HOWARD, S. K., BORG, L. K., SHUM, C., UDANI, A. D., MARIANO, E. R. (2018). A Pilot Project Using Eye-Tracking Technology to Design a Standardised Anaesthesia Workspace. Turkish Journal of Anaesthesiology and Reanimation, Cilt: 46 - Sayı: 6, 411–415. https://ajindex.com/articles/370209

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Hyder JA, Bohman JK, Kor DJ, Subramanian A, Bittner EA, Narr BJ, et al. Anesthesia Care Transitions and Risk of Postoperative Complications. Anesth Analg 2016
  2. [CrossRef ] 2. Saager L, Hesler BD, You J, Turan A, Mascha EJ, Sessler DI, et al. Intraoperative transitions of anesthesia care and postoperative adverse outcomes. Anesthesiology 2014
  3. [CrossRef ] 3. Jones PM, Cherry RA, Allen BN, Jenkyn KMB, Shariff SZ, Flier S, et al. Association Between Handover of Anesthesia Care and Adverse Postoperative Outcomes Among Patients Undergoing Major Surgery. JAMA 2018
  4. [CrossRef ] 4. Terekhov MA, Ehrenfeld JM, Dutton RP, Guillamondegui OD, Martin BJ, Wanderer JP. Intraoperative Care Transitions Are Not Associated with Postoperative Adverse Outcomes. Anesthesiology 2016
  5. [CrossRef ] 5. Jayaswal S, Berry L, Leopold R, Hart SR, Scuderi-Porter H, Digiovanni N, et al. Evaluating safety of handoffs between anesthesia care providers. Ochsner J 2011
  6. Caruso TJ, Marquez JL, Wu DS, Shaffer JA, Balise RR, Groom M, et al. Implementation of a standardized postanesthesia care handoff increases information transfer without increasing handoff duration. Jt Comm J Qual Patient Saf 2015
  7. [CrossRef ] 7. Gaba DM, Fish KJ, Howard SK, editors. Crisis Management in Anesthesiology: Churchill Livingstone
  8. Lobaugh LMY, Martin LD, Schleelein LE, Tyler DC, Litman RS. Medication Errors in Pediatric Anesthesia: A Report From the Wake Up Safe Quality Improvement Initiative. Anesth Analg 2017
  9. [CrossRef ] 9. Orser BA, Chen RJ, Yee DA. Medication errors in anesthetic practice: a survey of 687 practitioners. Can J Anaesth 2001
  10. [CrossRef ] 10. Grigg EB, Martin LD, Ross FJ, Roesler A, Rampersad SE, Haberkern C, et al. Assessing the Impact of the Anesthesia Medication Template on Medication Errors During Anesthesia: A Prospective Study. Anesth Analg 2017
  11. [CrossRef ] 11. Decker B. Ergonomics in the operating room - from the anesthesiologist’s point of view. Minim Invasive Ther Allied Technol 2003
  12. [CrossRef ] 12. Borg LK, Harrison TK, Kou A, Mariano ER, Udani AD, Kim TE, et al. Preliminary Experience Using Eye-Tracking Technology to Differentiate Novice and Expert Image Interpretation for Ultrasound-Guided Regional Anesthesia. J Ultrasound Med 2018