Journals / Turkish Journal of Engineering and Environmental Sciences / 2008 / Cilt: 32 - Sayı: 1

Investigation of the Effects of Orientation and Window Usage on External Walls in Terms of Heating and Cooling Energy

Pages
23–33
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In conclusion, OR1/1 (square formed) buildings have the minimum heating and cooling requirements.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This study investigated effective ways of minimizing the amount of energy used for heating and cooling caused by windows in the building envelope.
📊
Key Findings & Data:The hourly total heating and cooling energy calculations were carried out for the 1st, 11th, and 21st days of each month using the previous 10-year period's meteorological data for Elazığ.
💡
Conclusion & Impact:In conclusion, OR1/1 (square formed) buildings have the minimum heating and cooling requirements.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Energy conservation · Double-glass · Heating and cooling energy requirements

Abstract

This study investigated effective ways of minimizing the amount of energy used for heating and cooling caused by windows in the building envelope. The use of glass material in windows is discussed in terms of reducing heating and cooling energy consumption. The hourly total heating and cooling energy calculations were carried out for the 1st, 11th, and 21st days of each month using the previous 10-year period's meteorological data for Elazığ. Energy loads of windows were estimated using a computer program written in MATLAB. Energy requirements of different building facade examples caused by window glass were evaluated and the optimum facades determined among different alternatives. In conclusion, OR1/1 (square formed) buildings have the minimum heating and cooling requirements. Among 5 different glass alternatives, xenon filled double glass units require 33%-82% less heating and cooling energy than the others.

Özet

This study investigated effective ways of minimizing the amount of energy used for heating and cooling caused by windows in the building envelope. The use of glass material in windows is discussed in terms of reducing heating and cooling energy consumption. The hourly total heating and cooling energy calculations were carried out for the 1st, 11th, and 21st days of each month using the previous 10-year period's meteorological data for Elazığ. Energy loads of windows were estimated using a computer program written in MATLAB. Energy requirements of different building facade examples caused by window glass were evaluated and the optimum facades determined among different alternatives. In conclusion, OR1/1 (square formed) buildings have the minimum heating and cooling requirements. Among 5 different glass alternatives, xenon filled double glass units require 33%-82% less heating and cooling energy than the others.

🔖

Cite This Article

EKİCİ, B. B., AKSOY, U. T. (2008). Investigation of the Effects of Orientation and Window Usage on External Walls in Terms of Heating and Cooling Energy. Turkish Journal of Engineering and Environmental Sciences, Cilt: 32 - Sayı: 1, 23–33. https://ajindex.com/articles/369084

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...