Journals / The Anatolian Journal of Cardiology / 2017 / Cilt: 17 - Sayı: 6

A practical guide for building a highway between atria during transseptal puncture without radiation

Pages
470–472
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

However, the procedure of crossing septum was completed without any fluoroscopy use in track group, which showed a shorter procedure time than trackless group (4±3 s vs. 20±10 s, p<0.01).Conclusion: Visualizing the track passing through the puncture site using Carto3 system can guide the ablation catheter in safely crossing the intra-atrial septum quickly with zero fluoroscopy.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: To investigate whether switching the ablation catheter between the right and left atria through transseptal puncture site can be accurately performed without fluoroscopy.Methods: Forty patients with persistent atrial fibrillation (mean age, 60.2±7.4 years; 65% males) got \"2C3L\" approach were randomized in a 1:1 ratio to undergo either crossing interatrial septum guided by fluoroscopy (trackless group) or crossing septum guided by track image that was mapped by Carto3 system (track group).Results: The three-dimensional image of the track could be mapped smoothly and shown clearly.
📊
Key Findings & Data:No significant differences were found in the success rates between the two groups (100% vs. 100%, p>0.05).
💡
Conclusion & Impact:However, the procedure of crossing septum was completed without any fluoroscopy use in track group, which showed a shorter procedure time than trackless group (4±3 s vs. 20±10 s, p<0.01).Conclusion: Visualizing the track passing through the puncture site using Carto3 system can guide the ablation catheter in safely crossing the intra-atrial septum quickly with zero fluoroscopy.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: To investigate whether switching the ablation catheter between the right and left atria through transseptal puncture site can be accurately performed without fluoroscopy.Methods: Forty patients with persistent atrial fibrillation (mean age, 60.2±7.4 years; 65% males) got \"2C3L\" approach were randomized in a 1:1 ratio to undergo either crossing interatrial septum guided by fluoroscopy (trackless group) or crossing septum guided by track image that was mapped by Carto3 system (track group).Results: The three-dimensional image of the track could be mapped smoothly and shown clearly. No significant differences were found in the success rates between the two groups (100% vs. 100%, p>0.05). However, the procedure of crossing septum was completed without any fluoroscopy use in track group, which showed a shorter procedure time than trackless group (4±3 s vs. 20±10 s, p<0.01).Conclusion: Visualizing the track passing through the puncture site using Carto3 system can guide the ablation catheter in safely crossing the intra-atrial septum quickly with zero fluoroscopy.

🔖

Cite This Article

YUAN, Y., LONG, D., SANG, C., TAO, L., DONG, J., MA, C. (2017). A practical guide for building a highway between atria during transseptal puncture without radiation. The Anatolian Journal of Cardiology, Cilt: 17 - Sayı: 6, 470–472. https://ajindex.com/articles/367275

References (12)

  1. Earley MJ. How to perform a transseptal puncture. Heart 2009; 95: 85-92
  2. Dong JZ, Sang CH, Yu RH, Long DY, Tang RB, Jiang CX, et al. Prospective randomized comparison betweena fixed \'2C3L\' approach vs. stepwise approach for catheter ablation of persistent atrial fibrillation. Europace 2015; 17: 1798-806
  3. Klimek-Piotrowska W, Hołda MK, Koziej M, Hołda J, Piątek K, Tyrak K, et al. Clinical anatomy of the cavotricuspid isthmus and terminal crest. PLoS One 2016; 11: e0163383
  4. Cho Y, Lee W, Park EA, Oh IY, Choi EK, Seo JW. The anatomical characteristics of three different endocardial lines in the left atrium: evaluation by computed tomography prior to mitral isthmus block attempt. Europace 2012; 14: 1104-11
  5. Morady F, Oral H, Chugh A. Diagnosis and ablation of atypical atrial tachycardia and flutter complicating atrial fibrillation ablation. Heart Rhythm 2009; 6: S29-32
  6. Alhajiri A, Ramadan MM, Senior R. Left atrial enlargement causing dysphagia and weight loss: a rare contraindication for catheter ablation therapy in a patient with complex atrial arrhythmia. Int J Cardiol 2014; 177: e111-2
  7. Klimek-Piotrowska W, Hołda MK, Koziej M, Piątek K, Hołda J. Anatomy of the true interatrial septum for transseptal access to the left atrium. Ann Anat 2016; 205: 60-4
  8. Gul EE, Baranchuk A, Glover BM. A Guide to Transseptal Access. Can J Cardiol 2016 Oct 21. Epub ahead of print
  9. Lim HE, Choi CU, Na JO, Choi JI, Kim SH, Kim JW, et al. Effects of iatrogenic myocardial injury on coronary microvascular function in patients undergoing radiofrequency catheter ablation of atrial fibrillation. Circ Arrhythm Electrophysiol 2013; 6: 318-26
  10. Winkle RA, Mead RH, Engel G, Patrawala RA. The use of a radiofrequency needle improves the safety and efficacy of transseptal puncture for atrial fibrillation ablation. Heart Rhythm 2011; 8: 1411-5
  11. Chen K, Sang C, Dong J, Ma C. Transseptal puncture through Amplatzer septal occluder device for catheter ablation of atrial fibrillation: use of balloon dilatation technique. J Cardiovasc Electrophysiol 2012; 23: 1139-41
  12. Rodriguez-Manero M, Martinez-Sande JL, Fandino R, GarcíaSeara J, Chierchia GB, Fernández-López XA, et al. Fluoroscopic integration of the cardiac computed tomography as a guide for transseptal puncture during atrial fibrillation ablation: A feasibility study. Int J Cardiol 2015; 184: 274-5.