Journals / The Anatolian Journal of Cardiology / 2019 / Cilt: 22 - Sayı: 6

A unique late complication of transcatheter atrial septal defect closure

Pages
335–337
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Here we present a unique late complicationof transcatheter closure of secundum type ASD

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Secundum type atrial septal defects (ASD) are the most common type of interatrial shunts.
📊
Key Findings & Data:Transcatheter closure is widelyused in suitable cases.
💡
Conclusion & Impact:Here we present a unique late complicationof transcatheter closure of secundum type ASD
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Secundum type atrial septal defects (ASD) are the most common type of interatrial shunts. Transcatheter closure is widelyused in suitable cases. Although transcatheter closure has manyadvantages over surgical correction, it also has many early andlate complications. Here we present a unique late complicationof transcatheter closure of secundum type ASD

🔖

Cite This Article

ALTUNBAŞ, G., CELKAN, M. A., VURUŞKAN, E., SUCU, M. (2019). A unique late complication of transcatheter atrial septal defect closure. The Anatolian Journal of Cardiology, Cilt: 22 - Sayı: 6, 335–337. https://ajindex.com/articles/366676

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Amin Z, Hijazi ZM, Bass JL, Cheatham JP, Hellenbrand WE, Kleinman CS. Erosion of Amplatzer septal occlude device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 2004; 63: 496-502
  2. Kenny D, Eicken A, Dähnert I, Boudjemline Y, Sievert H, Schneider MB, et al. A randomized, controlled, multi-center trial of the efficacy and safety of the Occlutech Figulla Flex-II Occluder compared to the Amplatzer Septal Occluder for transcatheter closure of secundum atrial septal defects. Catheter Cardiovasc Interv 2019; 93: 316-21
  3. Werner RS, Prêtre R, Maisano F, Wilhelm MJ. Fracture of a Transcatheter Atrial Septal Defect Occluder Device Causing Mitral Valve Perforation. Ann Thorac Surg 2019; 108: e29-e30
  4. Kim JS, Yeom SY, Kim SH, Choi JW, Kim KH. Delayed left atrial perforation associated with erosion after device closure of an atrial septal defect. Korean J Thorac Cardiovasc Surg 2017; 50: 110-3
  5. Kim HH, Yi GJ, Song SW. Late migration of Amplatzer septal occluder device to the descending thoracic aorta. Korean J Thorac Cardiovasc Surg 2017; 50: 47-9.6. Scognamiglio G, Barracano R, Colonna D, MatteraIacono A, Santoro G, Spadafora A, et al. A very late life-threatening complication after percutaneous closure of an atrial septal defect. Can J Cardiol 2017; 33: 293.e1-293.e2