Journals / The Anatolian Journal of Cardiology / 2015 / Cilt: 15 - Sayı: 7

The relationship between atrial electromechanical delay and left atrial mechanical function in stroke patients

Pages
565–570
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: According to the results of our study, interatrial electromechanical delay may be a new predictor for ischemic stroke.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study was to evaluate the relationship between atrial electromechanical delay (EMD) measured with tissue Doppler imaging (TDI) and left atrial (LA) mechanical functions in patients with ischemic stroke and compare them with healthy controls.
📊
Key Findings & Data:The control group consisted of 35 age- and gender-matched apparently healthy individuals patients.
💡
Conclusion & Impact:Conclusion: According to the results of our study, interatrial electromechanical delay may be a new predictor for ischemic stroke.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of this study was to evaluate the relationship between atrial electromechanical delay (EMD) measured with tissue Doppler imaging (TDI) and left atrial (LA) mechanical functions in patients with ischemic stroke and compare them with healthy controls. Methods: Thirty patients with ischemic stroke were enrolled into this cross-sectional, observational study. The control group consisted of 35 age- and gender-matched apparently healthy individuals patients. Acute cerebral infarcts of probable embolic origin were diagnosed via imaging and were confirmed by a neurologist. Echocardiographically, time intervals from the beginning of P wave to beginning of A wave from the lateral and septal mitral and right ventricular tricuspid annuli in TDI were recorded. The differences between these intervals gave the mechanical delays (inter- and intra-atrial). Left atrial (LA) volumes were measured using the biplane area-length method, and LA mechanical function parameters were calculated. Statistical analysis was performed using student s t-test, chi-squared test, and Pearson s test. Results: The laboratory and clinical characteristics were similar in the two groups. Increased left atrial EMD (21.36±10.38 ms versus 11.74±6.06 ms, p<0.001), right atrial EMD (13.66±8.62 ms versus 9.66±6.81 ms, p=0.040), and interatrial EMD (35.03±9.95 ms versus 21.40±8.47 ms, p<0.001) were observed in stroke patients as compared to controls. Active LA emptying volume and fraction and passive LA emptying volumes and fraction were similar between controls and stroke patients. Total LA emptying volumes were significantly increased in stroke patients as compared to healthy controls (33.19±11.99 mL/m2 versus 27.48±7.08 mL/m2, p=0.021). Conclusion: According to the results of our study, interatrial electromechanical delay may be a new predictor for ischemic stroke.

🔖

Cite This Article

AKIL, M. A., AKIL, E., BİLİK, M. Z., OYLUMLU, M., ACET, H., YILDIZ, A., AKYÜZ, A., ERTAŞ, F., TOPRAK, N. (2015). The relationship between atrial electromechanical delay and left atrial mechanical function in stroke patients. The Anatolian Journal of Cardiology, Cilt: 15 - Sayı: 7, 565–570. https://ajindex.com/articles/365615

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Rein AJ, O’Donnell CP, Colan SD, Marx GR. Tissue velocity Doppler assessment of atrial and ventricular electromechanical coupling and atrioventricular time intervals in normal subjects. Am J Cardiol 2003
  2. [CrossRef] 2. Ermiş N, Açıkgöz N, Yaşar E, Taşolar H, Yağmur J, Cansel M, et al. Evaluation of atrial conduction time by P wave dispersion and tissue Doppler echocardiography in prehypertensive patients. Turk Kardiyol Dern Ars 2010
  3. Özer N, Yavuz B, Can I, Atalar E, Aksöyek S, Övünç K, et al. Doppler tissue evaluation of intraatrial and interatrial electromechanical delay and comparison with P-wave dispersion in patients with mitral stenosis. J Am Soc Echocardiogr 2005
  4. [CrossRef] 4. Bennett D. Atrial fibrillation. Eur Heart J 1984
  5. 5 Suppl A: 89-93. 5. Rojo-Martinez E, Sandin-Fuentes M, Calleja-Sanz AI, Cortijo-Garcia E, Garcia-Bermejo P, Ruiz-Pinero M, et al. High performance of an implantable Holter monitor in the detection of concealed paroxysmal atrial fibrillation in patients with cryptogenic stroke and a suspected embolic mechanism. Rev Neurol 2013
  6. Quinones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA. Recommendations for quantification of Doppler echocardiogra- phy: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 2002
  7. [CrossRef] 7. Haffajee JA, Lee Y, Alsheikh-Ali AA, Kuvin JT, Pandian NG, Patel AR. Pre-operative left atrial mechanical function predicts risk of atrial fibrillation following cardiac surgery. JACC Cardiovasc Imaging 2011
  8. [CrossRef] 8. Acar G, Akçay A, Sökmen A, Özkaya M, Güler E, Sökmen G, et al. Assessment of atrial electromechanical delay, diastolic functions, and left atrial mechanical functions in patients with type 1 diabetes mellitus. J Am Soc Echocardiogr 2009
  9. [CrossRef] 9. Dilaveris PE, Gialafos EJ, Sideris SK, Theopistou AM, Andrikopoulos GK, Kyriakidis M, et al. Simple electrocardiographic markers for the prediction of paroxysmal idiopathic atrial fibrillation. Am Heart J 1998
  10. [CrossRef] 10. Ferro JM. Cardioembolic stroke: an update. Lancet Neurol 2003
  11. [CrossRef] 11. Bang OY, Lee PH, Joo SY, Lee JS, Joo IS, Huh K. Frequency and mechanisms of stroke recurrence after cryptogenic stroke. Ann Neurol 2003
  12. [CrossRef] 12. Jickling GC, Stamova B, Ander BP, Zhan X, Liu D, Sison SM, et al