Journals / The Anatolian Journal of Cardiology / 2018 / Cilt: 19 - Sayı: 5

Increased microvolt T-wave alternans in children and adolescents with Eisenmenger syndrome

Pages
303–310
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The Tei indexwas significantly correlated with lead aVF.Conclusion: The MTWA lead V5 value was significantly higher in children with ES than in controls and was also correlated with decreasedexercise tolerance

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: To determine the values of microvolt T-wave alternans (MTWA) in children and adolescents with Eisenmenger syndrome (ES) andcontrols.Methods: Thirteen were included in the study.
📊
Key Findings & Data:After analyzing the 24-h ECG recordings, MTWA was considered using three leads (V5, V1, andaVF).
💡
Conclusion & Impact:The Tei indexwas significantly correlated with lead aVF.Conclusion: The MTWA lead V5 value was significantly higher in children with ES than in controls and was also correlated with decreasedexercise tolerance
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: To determine the values of microvolt T-wave alternans (MTWA) in children and adolescents with Eisenmenger syndrome (ES) andcontrols.Methods: Thirteen were included in the study. After analyzing the 24-h ECG recordings, MTWA was considered using three leads (V5, V1, andaVF). Right heart catheterization and 6-minute walk test (6-MWD) were applied to the patients and pro-brain natriuretic peptide levels were assessed;echocardiographic parameters were obtained from both the groups and the results were compared.Results: The MTWA value in lead V5 was 81.08±10.73 µV in the patient group (63.50±18.78 µV in the control group), in lead V1 was 75.00±16.86µV (73.94±16.77 µV in the control group), and in lead aVF was 73.77±17.81 µV (72.61±16.21 µV in the control group). Comparison of MTWA valuesbetween patients and controls revealed that only lead V5 values were statistically different in the ES group. The 6-MWD scores significantlycorrelated with lead V5. Right atrial volume and right ventricular fractional area change were significantly correlated with lead V1. The Tei indexwas significantly correlated with lead aVF.Conclusion: The MTWA lead V5 value was significantly higher in children with ES than in controls and was also correlated with decreasedexercise tolerance

🔖

Cite This Article

KARPUZ, D., HALLIOĞLU, O., YILMAZ, D. Ç. (2018). Increased microvolt T-wave alternans in children and adolescents with Eisenmenger syndrome. The Anatolian Journal of Cardiology, Cilt: 19 - Sayı: 5, 303–310. https://ajindex.com/articles/365257

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Douwes JM, Hegeman AK, van der Krieke MB, Roofthooft MT, Hillege HL, Berger RM. Six-minute walking distance and decrease in oxygen saturation during the six-minute walk test in pediatric pulmonary arterial hypertension. Int J Cardiol 2016; 202: 34-9. [CrossRef] Danilowicz-Szymanowicz L, Lewicka E, Dabrowska-Kugacka A, Niemirycz-Makurat A, Kwiatkowska J, Lewicka-Potocka Z, et al. Microvolt T-wave alternans profiles in patients with pulmonary arterial hypertension compared to patients with left ventricular systolic dysfunction and a group of healthy volunteers. Anatol J Cardiol 2016; 16: 825-30. [CrossRef] Lewicka E, Danitowicz-Szymanowicz L, Dabrowska-Kugacka A, Dabrowska-Kugacka A, Zieba B, Zagozdzon P, Raczak G. Microvolt T-wave alternans profile in patients with pulmonary arterial hypertension. Int J Cardiol 2014; 176: 1294-6. [CrossRef] Marcus JT, Gan CT, Zwanenburg JJ, Boonstra A, Allaart CP, Götte MJ, et al. Interventricular mechanical asynchrony in pulmonary arterial hypertension: left-to-right delay in peak shortening is related to right ventricular overload and left ventricular underfilling. J Am Coll Cardiol 2008; 51: 750-7. [CrossRef] Sakaki K, Ikeda T, Miwa Y, Miyakoshi M, Abe A, Tsukada T, et al. Time-domain T-wave alternans measured from Holter electrocardiograms predicts cardiac mortality in patients with left ventricular dysfunction: A prospective study. Heart Rhythm 2009; 6: 332-7.
  2. Trojnarska O, Cieplucha A, Bartczak A, Kramer L, Grajek S. Microvolt T-wave alternans in adults with complex congenital heart diseases. Cardiol J 2014; 21: 144-51. [CrossRef] Verrier RL, Klingenheben T, Malik M, El-Sherif N, Exner DV, Hohnloser SH, et al. Microvolt T-Wave Alternans Physiological Basis, Methods of Measurement,and Clinical Utility - Consensus Guideline by International Society for Holter and Noninvasive Electrocardiology. J Am Coll Cardiol 2011; 58: 1309-24. [CrossRef] Van der Avoort CJ, Filion KB, Dendukuri N, Brophy JM. Microvolt Twave alternans as a predictor of mortality and severe arrhythmias in patients with left-ventricular dysfunction: A systemic review and meta-analysis. BMC Cardiovascular Disord 2009; 9: 5-15. [CrossRef] Costantini O, Hohnloser SH, Kirk MM, Lerman BB, Baker JH 2nd, Sethuraman B, et al. The ABCD (Alternans Before Cardioverter Defibrillator) Trial: Strategies using T-wave alternans to improve efficiency of sudden cardiac death prevention. J Am Coll Cardiol 2009; 53: 471-9. [CrossRef] Kalogeropoulos AP, Border WL, Georgiopou