Objective & Hypothesis:Objective: Failure to select the optimal left ventricular (LV) segment for lead implantation is one of the most important causes of unresponsivenessto the cardiac resynchronization therapy (CRT).
📊
Key Findings & Data:In our study, we aimed to investigate the echocardiographic and clinical benefits of LV leadimplantation guided by an intraoperative 12-lead surface electrocardiogram (ECG) in patients with multiple target veins.Methods: We included 80 [42 (62.5%) male] heart failure patients who successfully underwent CRT defibrillator (CRT-D) implantation.
💡
Conclusion & Impact:Thus, it is a safe, feasible, and economic approach for CRT-D implantation.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: Failure to select the optimal left ventricular (LV) segment for lead implantation is one of the most important causes of unresponsivenessto the cardiac resynchronization therapy (CRT). In our study, we aimed to investigate the echocardiographic and clinical benefits of LV leadimplantation guided by an intraoperative 12-lead surface electrocardiogram (ECG) in patients with multiple target veins.Methods: We included 80 [42 (62.5%) male] heart failure patients who successfully underwent CRT defibrillator (CRT-D) implantation. Patientswere divided into two groups. In group 1, LV lead was positioned at the site with the shortest biventricular-paced (BiV-paced) QRS duration(QRSd), as intraprocedurally measured using surface ECG. In group 2 (control), we included patients who underwent the standard unguided CRT.ECG, echocardiogram, and functional status were evaluated before and 6 months after CRT implantation in all patients.Results: In group 1, BiV-paced QRSd measurements were successfully performed in 112 of 120 coronary sinus branches during CRT and an LVlead was successfully placed at the optimal site in all patients. Compared with group 2, group 1 had a significantly higher rate (85% vs. 50%,p=0.02) of response (>15% reduction in LV end-systolic volume) to CRT as well as a shorter QRSd (p<0.001) and a greater QRS shortening (∆QRS)associated with CRT compared with baseline (p<0.001). The mean New York Heart Association functional class was significantly improved inboth groups, and no significant differences were found in clinical response to CRT (85% vs. 70%, p=0.181).Conclusion: Surface ECG can be used to guide LV lead placement in patients with multiple target veins for improving response to CRT. Thus, it is a safe, feasible, and economic approach for CRT-D implantation.

🔖

Cite This Article

ŞİPAL, A., BOZYEL, S., AKTAŞ, M., DERVİS, E., AKBULUT, T., ARGAN, O., ÇELİKYURT, U., URAL, D., ŞAHİN, T., AĞIR, A., VURAL, A. (2018). Surface electrogram-guided left ventricular lead placement improves response to cardiac resynchronization therapy. The Anatolian Journal of Cardiology, Cilt: 19 - Sayı: 3, 184–191. https://ajindex.com/articles/365250

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (4)

  1. de Cock CC, Res JC, Hendriks ML, Allaart CP. Usefulness of a pacing guidewire to facilitate left ventricular lead implantation in cardiac resynchronization therapy. Pacing Clin Electrophysiol 2009; 32: 446- 9. [CrossRef] Korantzopoulos P, Zhang Z, Li G, Fragakis N, Liu T. Meta-Analysis of the Usefulness of Change in QRS Width to Predict Response to Cardiac Resynchronization Therapy. Am J Cardiol 2016; 118: 1368-73.
  2. Bakos Z, Markstad H, Ostenfeld E, Carlsson M, Roijer A, Borgquist R. Combined preoperative information using a bullseye plot from speckle tracking echocardiography, cardiac CT scan, and MRI scan: targeted left ventricular lead implantation in patients receiving cardiac resynchronization therapy. Eur Heart J Cardiovasc Imaging 2014; 15: 523-31. [CrossRef] Menet A, Bardet-Bouchery H, Guyomar Y, Graux P, Delelis F, Castel AL, et al. Prognostic importance of postoperative QRS widening in patients with heart failure receiving cardiac resynchronization therapy. Heart Rhythm 2016; 13: 1636-43. [CrossRef] Hsing JM, Selzman KA, Leclercq C, Pires LA, McLaughlin MG, McRae SE, et al. Paced left ventricular QRS width and ECG parameters predict outcomes after cardiac resynchronization therapy: PROSPECT-ECG substudy. Circ Arrhythm Electrophysiol 2011; 4: 851-7. [CrossRef] Liang Y, Yu H, Zhou W, Xu G, Sun YI, Liu R, et al. Left Ventricular Lead Placement Targeted at the Latest Activated Site Guided by Elec trophysiological Mapping in Coronary Sinus Branches Improves Response to Cardiac Resynchronization Therapy. J Cardiovasc Electrophysiol 2015; 26: 1333-9. [CrossRef] Martí-Bonmatí L, Sopena R, Bartumeus P, Sopena P. Multimodality imaging techniques. Contrast Media Mol Imaging 2010; 5: 180-9.
  3. Zhang X, Ha S, Wang X, Shi Y, Duan S, Li Z. Speckle tracking echocardiography: clinical applications in cardiac resynchronization therapy. Int J Clin Exp Med 2015; 8: 6668-76.
  4. Choi J, Radau P, Xu R, Wright GA. X-ray and magnetic resonance imaging fusion for cardiac resynchronization therapy. Med Image Anal 2016; 31: 98-107. [CrossRef] Bertini M, Mele D, Malagù M, Fiorencis A, Toselli T, Casadei F, et al. Cardiac resynchronization therapy guided by multimodality cardiac imaging. Eur J Heart Fail 2016; 18: 1375-82. [CrossRef] Sommer A, Kronborg MB, Nørgaard BL, Poulsen SH, Bouchelouche K, Böttcher M, et al. Multimodality imaging-guided left ventricular lead placement in cardiac resynchronization therapy: a randomized controlled trial. Eur J Heart Fail 2016; 18: 1365-74. [Cro