Journals / The Anatolian Journal of Cardiology / 2021 / Cilt: 25 - Sayı: 10

Clinical outcomes of ultrathin biodegradable polymer-coated sirolimus-eluting stents in an all-comer population: One-year results from the T-FLEX registry including high-risk subgroups

Pages
706–715
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

During follow-up, stent thrombosis was reported in 0.8% (95% CI: 0.4–1.5) patients in the overall population.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: T-Flex registry was designed to investigate the safety and clinical performance of the ultrathin (60 μm) strut biodegradable polymer-coated sirolimus-eluting stent (SES) with a unique long dual Z (LDZ) link design on a cobalt-chromium stent platform (Sahajanand Medical Technologies Pvt.
📊
Key Findings & Data:A total of 1,203 patients treated with an ultrathin biodegradable polymer-coated SES, irrespective of lesion complexity, comorbidities, and acute presentation were analyzed from May 2016 to January 2017.
💡
Conclusion & Impact:During follow-up, stent thrombosis was reported in 0.8% (95% CI: 0.4–1.5) patients in the overall population.
🔬Design:Research Article
📍Scope:2016 Verileri
⚙️Variables:Domain Parameters

Özet

Objective: T-Flex registry was designed to investigate the safety and clinical performance of the ultrathin (60 μm) strut biodegradable polymer-coated sirolimus-eluting stent (SES) with a unique long dual Z (LDZ) link design on a cobalt-chromium stent platform (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) in a real-world all-comer population including high-risk subgroups. Methods: This was an observational, multicenter, single-arm, and investigator-initiated retrospective registry. A total of 1,203 patients treated with an ultrathin biodegradable polymer-coated SES, irrespective of lesion complexity, comorbidities, and acute presentation were analyzed from May 2016 to January 2017. The primary endpoint was the one-year incidence of target lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction (TV-MI), and clinically-indicated target lesion revascularization (CI-TLR). Stent thrombosis was assessed as an additional safety endpoint. Results: At the one-year follow-up, TLF was observed in 3.8% [95% confidence interval (CI) 2.9–5.1] patients, composed of 0.6% (95% CI: 0.3–1.3) cardiac death, 1.3% (95% CI: 0.8–2.2) TV-MI, and 1.9% (95% CI: 1.3–2.9) CI-TLR. In the high-risk subgroups, TLF at one-year was 6.8% (95% CI: 4.6–9.8) in patients with diabetes, 5.2% (95% CI: 3.4–8) in patients with small-vessel disease, 6.1% (95% CI: 3.9-9.6) in patients with ST-elevation myocardial infarction, and 4.5% (95% CI: 2.4-8.3) in patients with total occlusion. During follow-up, stent thrombosis was reported in 0.8% (95% CI: 0.4–1.5) patients in the overall population. Conclusion: Low event rates of TLF and stent thrombosis at one-year follow-up indicate that this ultrathin biodegradable polymer-coated SES has encouraging safety and clinical performance in real-world all-comer populations as well as in high-risk subgroups.

🔖

Cite This Article

POTHİNENİ, R. B., VİJAN, V., POTDAR, A., İNAMDAR, M. K., PATHAK, A., MANTRAVADİ, S. S., AJMERA, P. (2021). Clinical outcomes of ultrathin biodegradable polymer-coated sirolimus-eluting stents in an all-comer population: One-year results from the T-FLEX registry including high-risk subgroups. The Anatolian Journal of Cardiology, Cilt: 25 - Sayı: 10, 706–715. https://ajindex.com/articles/365144

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. McFadden EP, Stabile E, Regar E, Cheneau E, Ong AT, Kinnaird T, et al. Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy. Lancet 2004
  2. [Crossref] 2. Lagerqvist B, Carlsson J, Fröbert O, Lindbäck J, Scherstén F, Stenestrand U, et al.
  3. Swedish Coronary Angiography and Angioplasty Registry Study Group. Stent thrombosis in Sweden: a report from the Swedish Coronary Angiography and Angioplasty Registry. Circ Cardiovasc Interv 2009
  4. [Crossref] 3. Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, et al. Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk. J Am Coll Cardiol 2006
  5. [Crossref] 4. Kalra A, Rehman H, Khera S, Thyagarajan B, Bhatt DL, Kleiman NS, et al. New-Generation Coronary Stents: Current Data and Future Directions. Curr Atheroscler Rep 2017
  6. [Crossref] 5. Simard T, Hibbert B, Ramirez FD, Froeschl M, Chen YX, O'Brien ER. The evolution of coronary stents: A brief review. Can J Cardiol 2014
  7. [Crossref] 6. Ho MY, Chen CC, Wang CY, Chang SH, Hsieh MJ, Lee CH, et al. The development of coronary artery stents: From bare-metal to bio-resorbable types. Metals 2016
  8. [Crossref] 7. Foerst J, Vorpahl M, Engelhardt M, Koehler T, Tiroch K, Wessely R. Evolution of coronary stents: From bare-metal stents to fully biodegradable, drug-eluting stents. Combination Products in Therapy 2013
  9. [Crossref] 8. John MC, Wessely R, Kastrati A, Schömig A, Joner M, Uchihashi M, et al. Differential healing responses in polymer-and nonpolymer-based sirolimus-eluting stents. JACC Cardiovasc Interv 2008
  10. [Crossref] 9. Puranik AS, Dawson ER, Peppas NA. Recent advances in drug eluting stents. Int J Pharm 2013
  11. [Crossref] 10. Kastrati A, Mehilli J, Dirschinger J, Dotzer F, Schuhlen H, Neumann FJ, et al. Intracoronary Stenting and Angiographic Results Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial. Vestn Rentgenol Radiol 2012
  12. [Article in Russian] 11. Pache J, Kastrati A, Mehilli J, Schühlen H, Dotzer F, Hausleiter J, et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial. J Am Coll Cardiol 2003
  13. [Crossref] 12. Lemos PA, Chandwani P, Saxena S, Ramachandran PK, Abhyankar A, Campos CM, et al. Clinical outcomes in 995 unselected real-world patients treated with an ultrathin biodegradable polymer-coated