Performance Analysis Of Inner-Tube Evacuated Solar Collector With Compound Parabolic Reflector For Steam Generation

Bütünleşik Parabolik Yansıtıcılı ve İç Borulu Vakum Tüplü Güneş Toplayıcısının Buhar Üretimi Performans Analizi

Pages
13–23
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Comparing of the experiental and analytical datas, the suitability of the ETSC with inner tube for steam genration and thermal efficeny was evaluated.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the thermal performance of evacuated tube solar collector (ETSC) with reflective surface and availability of system was investigated for steam generation.
📊
Key Findings & Data:In order to observe system performance, experiments were carried out in different outdoor conditions.
💡
Conclusion & Impact:Comparing of the experiental and analytical datas, the suitability of the ETSC with inner tube for steam genration and thermal efficeny was evaluated.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, the thermal performance of evacuated tube solar collector (ETSC) with reflective surface and availability of system was investigated for steam generation. For this purpose, the compound parabolic solar collector has been designed and manufactured. In order to observe system performance, experiments were carried out in different outdoor conditions. During the experiments, the feed water and steam outlet temperatures, the ambient temperature, the inner tube surface temperature, solar radiation and amount of steam generation were measured using thermocuples and pyranometer. In order to determine the heat loss from absorber surface to the enviroment, mathematical model was created with the help of experimental data and heat loss coefficient were calculated. Comparing of the experiental and analytical datas, the suitability of the ETSC with inner tube for steam genration and thermal efficeny was evaluated.

Özet

Bu çalışmada, yansıtıcı yüzey kullanılan iç borulu vakum tüplü güneş toplayıcısınınısıl performansı incelenerek, buhar üretiminde kullanılabilirliği araştırılmıştır. Buamaçla bütünleşik parabolik bir güneş toplayıcısının tasarım ve imalatı gerçekleştirilmiştir. Sistem performansını gözlemlemek için, farklı dış ortam koşullarındadeneyler yapılmıştır. Deneyler sırasında besleme suyu ve buhar çıkış sıcaklıkları,çevre sıcaklığı, vakum tüp dış yüzey sıcaklığı, iç boru yüzey sıcaklığı, güneş ışınımdeğeri ve üretilen buhar miktarı, ısıl çiftler ve piranometre kullanılarak ölçülmüştür. Yutucu yüzeyden çevreye olan ısı kaybını belirlemek için deneysel veriler yardımıyla matematiksel model oluşturulmuş ve ısı kayıp katsayıları hesaplanmıştır. Bumodel sonucunda elde edilen sayısal sonuçlar deneysel verilerle karşılaştırılarak,yansıtıcılı iç borulu güneş toplayıcısının ısıl verimi ve buhar üretimine uygunluğudeğerlendirilmiştir.

🔖

Cite This Article

SERVER, A., KÜÇÜKA, S. (2020). Performance Analysis Of Inner-Tube Evacuated Solar Collector With Compound Parabolic Reflector For Steam Generation. Tesisat Mühendisliği, Cilt: 2020 - Sayı: 179, 13–23. https://ajindex.com/articles/364750

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Kalogirou, S. A. “Solar Thermal Collectors and Applications” Progress in Energy and Combustion Science 30, 231–295, 2004
  2. Shah, L. J., Furbo, S., “Theoretical Flow Investigations Of An All Glass Evacuated Tubular Collector” Solar Energy 81, 822–82, 2007
  3. Ataee, S., Ameri, M., “Energy and Exergy Analysis Of All-Glass Evacuated Solar Collector Tubes With Coaxial Fluid Conduit” Solar Energy 118, 575–591, 2015
  4. Yadav, M., Saikhedkar N. K., “Simulation Modelling For the Performance of Evacuated Tube Solar Collector”, www.ijirset.com Vol. 6, Issue 4, April 2017
  5. Yang, J., Jiang, Q., Hou, J., Luo, C., “A Study on Thermal Performance of a Novel All-Glass Evacuated Tube Solar Collector Manifold Header with an Inserted Tube”, International Journal of Photoenergy Volume 2015, Article ID 409517, 7 pages [6] Kumar, S. S., Kumar, K. M., Kumar, S. R. S., “Design of Evacuated Tube Solar Collector with Heat Pipe”, Materials Today: Proceedings 4, 12641–12646, 2017
  6. Jafarkazemi, F., Abdi, H., “Evacuated Tube Solar Heat Pipe Collector Model And Associated tests”, Journal of Renewable and Sustainable Energy 4, 023101, 2012
  7. Topal, M. A., “Isı Borulu Vakum Tüplü Güneş Kollektörlerinde Nanoakışkan Kullanımının Performansa Etkisi”, Karabük Üniversitesi, Enerji Sistemleri Mühendisliği, 2018
  8. Ma, L., Lu, Z., Zhang, J., Liang, R., “Thermal Performance Analysis Of The Glass Evacuated Tube Solar Collector With U-Tube”, Building and Environment 45, 1959e1967, 2010
  9. Ong, K. S., Tong, W. L. “System Performance of U-Tube and Heat Pipe Solar Water Heaters”, Journal of Applied Science and Engineering, Vol. 15, No. 2, pp. 105-110, 2012
  10. Farjallah, R., Chaabane, M., Mhiri, H., Bournot, P., Dhaouadi, H., “Thermal Performance of the U-Tube Solar Collector Using Computational Fluid Dynamics Simulation” Journal of Solar Energy Engineering Copyright VC 2016 by ASME DECEMBER 2016, Vol. 138 / 061008-1 [12] Gao, Y., Fan, R., Zhang, X. Y., An, Y. J., Wang, M. X., Gao, Y. K., Yu, Y., “Thermal Performance And Parameter Analysis Of A U-Pipe Evacuated Solar Tube Collector”, Solar Energy 107, 714–727, 2014
  11. Ghoneim, A. A., Shabana H. M., Shaaban, M. S., Mohammedien, A. M. “Performance Analysis of Evacuated Tube Collector in Hot Climate”, European International Journal of Science and Technology Vol. 5 No. 3 April, 2016
  12. Badar, A. W., Buchholz, R., Ziegler, F., “Experimental and Theoretical Evaluation Of The Overall Heat Loss Coefficient Of Vacuum Tubes Of