⚡ TL;DR(Too Long; Didn't Read)

There was a statistically significant difference between thegroups concerning comorbidity, postoperative complications, the length of hospitalization stay and recurrence.Conclusion: We believe that the onlay technique will be more appropriate than the inlay technique when only prolen mesh ispreferred because the recurrence rates are higher in the inlay technique.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: The selection of incision type, closure type of incision and the suture material are some of the important factors to prevent hernia development.
📊
Key Findings & Data:In this retrospective study, our main goal was to compare the recurrencerates in patients who underwent incisional hernia repair with onlay and inlay mesh techniques.Methods: This retrospective study included 185 patients who underwent surgery due to incisional hernia in our clinic betweenJanuary 2012 and October 2017.
💡
Conclusion & Impact:There was a statistically significant difference between thegroups concerning comorbidity, postoperative complications, the length of hospitalization stay and recurrence.Conclusion: We believe that the onlay technique will be more appropriate than the inlay technique when only prolen mesh ispreferred because the recurrence rates are higher in the inlay technique.
🔬Design:Research Article
📍Scope:2012 Verileri
⚙️Variables:Domain Parameters

Özet

Objectives: The selection of incision type, closure type of incision and the suture material are some of the important factors to prevent hernia development. We should aim to perform the best procedure with the best technique to reduce the risk of recurrence.Surgical options include primary repair and open or laparoscopic repair with mesh. Mesh repairs can be performed as onlay, sublayor inlay according to the area where the mesh is to be laid. In this retrospective study, our main goal was to compare the recurrencerates in patients who underwent incisional hernia repair with onlay and inlay mesh techniques.Methods: This retrospective study included 185 patients who underwent surgery due to incisional hernia in our clinic betweenJanuary 2012 and October 2017. Patients were divided into two groups according to the technique as Group 1 with onlay meshrepair and Group 2 with inlay mesh repair. The same type of mesh (prolen) was applied to all patients.Results: There were 121 patients in Group 1 and 64 patients in Group 2. According to data we obtained, 64.3% of the patients werewomen and the mean age of all patients was 58.4±16.4 years. Postoperative complications (such as seroma-hematoma, surgicalsite infection, mesh rejection, postoperative ileus) developed in 29.2% (n=54) of the patients. The length of hospital stay was 4.2±3days in Group 1 and 5.6±5 days in Group 2. The mean follow-up period was 48.6 months (24-93 months), with the recurrence ratesof 5.8% (n=7) in Group 1 and 10.9% (n=7) in Group 2, respectively. There was a statistically significant difference between thegroups concerning comorbidity, postoperative complications, the length of hospitalization stay and recurrence.Conclusion: We believe that the onlay technique will be more appropriate than the inlay technique when only prolen mesh ispreferred because the recurrence rates are higher in the inlay technique.

🔖

Cite This Article

ACAR, T., ACAR, N., SÜR, Y., KAMER, E., ATAHAN, M. K., GENÇ, H., HACIYANLI, M. (2020). The Effects of Operation Technique on Recurrence of Incisional Hernia Repair. Şişli Etfal Hastanesi Tıp Bülteni, Cilt: 54 - Sayı: 1, 23–28. https://ajindex.com/articles/363687

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Ambe P, Meyer A, Köhler L. Repair of small and medium size ventral hernias with a Proceed Ventral Patch: a single center retrospective analysis. Surg Today 2013;43:381–5
  2. Flum DR, Horvath K, Koepsell T. Have outcomes of incisional hernia repair improved with time? A population-based analysis. Ann Surg 2003;237:129–35
  3. Cassar K, Munro A. Surgical treatment of incisional hernia. Br J Surg 2002;89:534–45
  4. Zarmpis N, Wassenberg D, Ambe PC. Repair of Small and Medium Size Umbilical Hernias with the "Proceed Ventral Patch" in the Preperitoneal Position. Am Surg 2015;81:1144–8
  5. Fink C, Baumann P, Wente MN, Knebel P, Bruckner T, Ulrich A, et al. Incisional hernia rate 3 years after midline laparotomy. Br J Surg 2014;101:51–4
  6. Venclauskas L, Silanskaite J, Kanisauskaite J, Kiudelis M. Longterm results of incisional hernia treatment. Medicina (Kaunas) 2007;43:855–60
  7. Bucknall TE, Cox PJ, Ellis H. Burst abdomen and incisional hernia: a prospective study of 1129 major laparotomies. Br Med J (Clin Res Ed) 1982;284:931–3
  8. Ellis H, Coleridge-Smith PD, Joyce AD. Abdominal incisions-vertical or transverse?. Postgrad Med J 1984;60:407–10
  9. DeSouza A, Domajnko B, Park J, Marecik S, Prasad L, Abcarian H. Incisional hernia, midline versus low transverse incision: what is the ideal incision for specimen extraction and hand-assisted laparoscopy?. Surg Endosc. 2011;25(4):1031–1036
  10. Halm JA, Lip H, Schmitz PI, Jeekel J. Incisional hernia after upper abdominal surgery: a randomised controlled trial of midline versus transverse incision. Hernia 2009;13:275–80
  11. Fassiadis N, Roidl M, Hennig M, South LM, Andrews SM. Randomized clinical trial of vertical or transverse laparotomy for abdominal aortic aneurysm repair. Br J Surg 2005;92:1208–11
  12. Martel G, Ahmad J, Taylor M. Novel treatment of refractory seroma after incisional hernia repair. Gut 2013;62:A19–20
  13. Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, IJzermans JN, et al. A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 2000;343:392–8
  14. Kingsnorth A, LeBlanc K. Hernias: inguinal and incisional. Lancet 2003;362:1561–71
  15. Saeed N, Iqbal SA, Shaikh BA, Baqai F. Comparison between onlay and sublay methods of mesh repair of incisional hernia. J Post Med Inst 2014;28:400–3
  16. Leithy M, Loulah M, Greida HA, Baker FA, Hayes AM. Sublay hernio plasty versus onlay hernioplasty in incisional hernia in diabetic patients. Menoufia Med J 2014;27:35