Randomized Prospective Comparison of Glidescope Video Laryngoscope with Macintosh Laryngoscope in Adult who Underwent Thyroid or Parathyroid Surgery Using Neuromonitorization

Pages
320–326
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

There was nosignificant difference between the groups’ number of trials and intubation-associated complications.Conclusion: Despite its long intubation time, we believe that GVL may be the first choice laryngoscopy method in the thyroidor parathyroid cases that intubated with a low dose muscle relaxant for neuromonitoring since it has a slight effect than ML onhemodynamism it does not increase mucosal damage and has improved visibility.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: The present study aims to compare the effects of Glidescope Video Laryngoscope (GVL) and Machintosh Laryngoscope(ML) on the hemodynamic response, intubation time and mucosal damage in adult patients who underwent thyroid orparathyroid surgery using neuromonitorization.Methods: In this study, 180 patients, aged between 22 and 65 classified as Class I-II in ASA (American Society of Anesthesiologists)and operated under elective conditions were included.
📊
Key Findings & Data:Patients were assigned into two groups: Patients intubated with GVL GroupG (n=90) and patients intubated with ML Group M (n=90).
💡
Conclusion & Impact:There was nosignificant difference between the groups’ number of trials and intubation-associated complications.Conclusion: Despite its long intubation time, we believe that GVL may be the first choice laryngoscopy method in the thyroidor parathyroid cases that intubated with a low dose muscle relaxant for neuromonitoring since it has a slight effect than ML onhemodynamism it does not increase mucosal damage and has improved visibility.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objectives: The present study aims to compare the effects of Glidescope Video Laryngoscope (GVL) and Machintosh Laryngoscope(ML) on the hemodynamic response, intubation time and mucosal damage in adult patients who underwent thyroid orparathyroid surgery using neuromonitorization.Methods: In this study, 180 patients, aged between 22 and 65 classified as Class I-II in ASA (American Society of Anesthesiologists)and operated under elective conditions were included. Patients were assigned into two groups: Patients intubated with GVL GroupG (n=90) and patients intubated with ML Group M (n=90). In both groups, intubation time and the number of trials were recorded.HR (Heart Rate), SpO2 (Peripheral Capillary Oxygen Saturation), SBP (Systolic Blood Pressure), DBP (Diastolic Blood Pressure) andMBP (Mean Blood Pressure) scores were recorded at preinduction, post-induction, post-intubation and three minutes after intubation.Post-operative intubation-associated complications were recorded.Results: Post intubation HR, DBP and MBP scores were found to be significantly higher in Group M than Group G (p=0,006, p=0.013,p=0.011). Intubation time was found to be significantly higher in Group G than in group M (35.3±10.3, 22.1±7.7 sec). There was nosignificant difference between the groups’ number of trials and intubation-associated complications.Conclusion: Despite its long intubation time, we believe that GVL may be the first choice laryngoscopy method in the thyroidor parathyroid cases that intubated with a low dose muscle relaxant for neuromonitoring since it has a slight effect than ML onhemodynamism it does not increase mucosal damage and has improved visibility.

🔖

Cite This Article

GÜNEŞ, M., ÇINAR, A. S., ULUDAĞ, M. (2020). Randomized Prospective Comparison of Glidescope Video Laryngoscope with Macintosh Laryngoscope in Adult who Underwent Thyroid or Parathyroid Surgery Using Neuromonitorization. Şişli Etfal Hastanesi Tıp Bülteni, Cilt: 54 - Sayı: 3, 320–326. https://ajindex.com/articles/363398

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Kayhan Z. Klinik Anestezi. 3rd ed. İstanbul: Logos Publishing; 2004. p. 243–73
  2. Channa AB. Video laryngoscopes. Saudi J Anaesth 2011;5:357–9
  3. İsgör A. Tiroid Hastalıkları ve Cerrahisi. 1st ed. Istanbul: Avrupa Tıp; 2000. p. 515–93
  4. Eisele DW. Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve. Laryngoscope 1996;106:443–49
  5. Han YD, Liang F, Chen P. Dosage effect of rocuronium on intraoperative neuromonitoring in patients undergoing thyroid surgery. Cell Biochem Biophys 2015;71:143–6
  6. Lu IC, Tsai CJ, Wu CW, Cheng KI, Wang FY, Tseng KY, et al. A comparative study between 1 and 2 effective doses of rocuronium for intraoperative neuromonitoring during thyroid surgery. Surgery 2011;149:543–8
  7. Parasa M, Yallapragada SV, Vemuri NN, Shaik MS. Comparison of GlideScope video laryngoscope with Macintosh laryngoscope in adult patients undergoing elective surgical procedures. Anesth Essays Res 2016;10:245–9
  8. Pournajafian AR, Ghodraty MR, Faiz SH, Rahimzadeh P, Goodarzynejad H, Dogmehchi E. Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial. Iran Red Crescent Med J 2014;16:e12334
  9. Misirlioglu G, Sen O. Comparison of GlideScope video laryngoscopy and Macintosh laryngoscope in ear-nose and throat surgery. Ir J Med Sci 2016;185:729–33
  10. Amini S, Shakib M. Hemodynamic changes following endotracheal intubation in patients undergoing cesarean section with general anesthesia: application of glidescope® videolaryngoscope versus direct laryngoscope. Anesth Pain Med 2015;5:e21836
  11. Dashti M, Amini S, Azarfarin R, Totonchi Z, Hatami M. Hemodynamic changes following endotracheal intubation with glidescope( ®) video-laryngoscope in patients with untreated hypertension. Res Cardiovasc Med 2014;3:e17598
  12. Kanotra SP, Kuriloff DB, Lesser J, Rest-Flarer F. GlideScope-assisted nerve integrity monitoring tube placement for intra-operative recurrent laryngeal nerve monitoring. J Laryngol Otol 2012;126:1271–3
  13. Aqil M, Khan MU, Hussain A, Khokhar RS, Mansoor S, Alzahrani T. Routine Use of Glidescope and Macintosh Laryngoscope by Trainee Anesthetists. J Coll Physicians Surg Pak 2016;26:245–9
  14. Cirilla DJ 2nd, Ngo J, Vaisman V, Daly C, Ata A, Sandison M, et al. Does the incidence of sore throat postoperatively increase with the use of a traditional intubation blade or the GlideScope? J Clin Anesth 2015;27:646–51