Journals / Şişli Etfal Hastanesi Tıp Bülteni / 2021 / Cilt: 55 - Sayı: 2

Anatomical, Functional, and Dynamic Evidences Obtained by Intraoperative Neuromonitoring Improving the Standards of Thyroidectomy

Pages
146–155
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Reduction of amplitude more than 50% on CTM is related with poor voice outcome.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The use of intraoperative neuromonitoring (IONM) is getting more common in thyroidectomy.
📊
Key Findings & Data:These evidences obtained through IONM increase the rate of detection and visual identification of recurrent laryngeal nerve (RLN) as well as the detection rate of extralaryngeal branches which are the most common anatomic variations of RLN.
💡
Conclusion & Impact:Reduction of amplitude more than 50% on CTM is related with poor voice outcome.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

The use of intraoperative neuromonitoring (IONM) is getting more common in thyroidectomy. The data obtained by the usage of IONM regarding the laryngeal nerves’ anatomy and function have provided important contributions for improving the standards of the thyroidectomy. These evidences obtained through IONM increase the rate of detection and visual identification of recurrent laryngeal nerve (RLN) as well as the detection rate of extralaryngeal branches which are the most common anatomic variations of RLN. IONM helps early identification and preservation of the non-recurrent laryngeal nerve. Crucial knowledge has been acquired regarding the complex innervation pattern of the larynx. Extralaryngeal branches of the RLN may contribute to the motor innervation of the cricothyroid muscle (CTM). Anterior branch of the extralaryngeal branching RLN has always motor function and gives motor branches both to the abductor and adductor muscles. In addition, up to 18% of posterior branches may have adductor and/ or abductor motor fibers. In 70–80% of cases, external branch of superior laryngeal nerve (EBSLN) provides motor innervation to the anterior 1/3 of the thyroarytenoid muscle which is the main adductor of the vocal cord through the human communicating nerve. Furthermore, approximately 1/3 of the cases, EBSLN may contribute to the innervation of posterior cricoarytenoid muscle which is the main abductor of ipsilateral vocal cord. RLN and/or EBSLN together with pharyngeal plexus usually contribute to the motor innervation of cricopharyngeal muscle that is the main component of upper esophageal sphincter. Traction trauma is the most common reason of RLN injuries and constitutes of 67–93% of cases. More than 50% of EBSLN injuries are caused by nerve transection. A specific point of injury on RLN can be detected in Type 1 (segmental) injury, however, Type 2 (global) injury is the loss of signal (LOS) throughout ipsilateral vagus-RLN axis and there is no electrophysiologically detectable point of injury. Vocal cord paralysis (VCP) develops in 70–80% of cases when LOS persists or incomplete recovery of signal occurs after waiting for 20 min. In case of complete recovery of signal, VCP is not expected. VCP is temporary in patients with incomplete recovery of signal and permanent VCP is not anticipated. Visual changes may be seen in only 15% of RLN injuries, on the other hand, IONM detects 100% of RLN injuries. IONM can prevent bilateral VCP. Continuous IONM (C-IONM) is a method in which functional integrity of vagus-RLN axis is evaluated in real time and C-IONM is superior to intermittent IONM (I-IONM). During upper pole dissection, IONM makes significant contributions to the visual and functional identification of EBSLN. Routine use of IONM may minimalize the risk of nerve injury. Reduction of amplitude more than 50% on CTM is related with poor voice outcome.

🔖

Cite This Article

AYGÜN, N., KÖSTEK, M., İŞGÖR, A., ULUDAĞ, M. (2021). Anatomical, Functional, and Dynamic Evidences Obtained by Intraoperative Neuromonitoring Improving the Standards of Thyroidectomy. Şişli Etfal Hastanesi Tıp Bülteni, Cilt: 55 - Sayı: 2, 146–155. https://ajindex.com/articles/363334

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Grover G, Sadler GP, Mihai R. Morbidity after thyroid surgery: patient perspective. Laryngoscope 2013;123:2319–23
  2. Nam IC, Park YH. Pharyngolaryngeal symptoms associated with thyroid disease. Curr Opin Otolaryngol Head Neck Surg 2017;25:469–74
  3. Lahey FH, Hoover WB. Injuries to the recurrent laryngeal nerve in thyroid operations: their management and avoidance. Ann Surg 1938;108:545–62
  4. Randolph GW, Dralle H; International Intraoperative Monitoring Study Group, Abdullah H, Barczynski M, Bellantone R, Brauckhoff M, et al. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 2011;121 Suppl 1:S1–16
  5. Shedd DP, Durham C. Electrical identification of the recurrent laryngeal nerve. I. Response of the canine larynx to electrical stimulation of the recurrent laryngeal nerve. Ann Surg 1966;163:47–50
  6. Riddell V. Thyroidectomy: prevention of bilateral recurrent nerve palsy. Results of identification of the nerve over 23 consecutive years (1946-69) with a description of an additional safety measure. Br J Surg 1970;57:1–11
  7. Eisele DW. Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve. Laryngoscope 1996;106:443–9
  8. Lamade W, Fogel W, Rieke K, Senninger N, Herfarth C. Intraoperative monitoring of the recurrent laryngeal nerve. A new method. [Article in German]. Chirurg 1996;67:451–4
  9. Lamadé W, Meyding-Lamadé U, Hund E, Senninger N, Herfarth C. Transtracheal monitoring of the recurrent laryngeal nerve. Prototype of a new tube. [Article in German]. Chirurg 1997;68:193–5
  10. Lamadé W, Ulmer C, Seimer A, Molnar V, Meyding-Lamadé U, Thon KP, et al. A new system for continuous recurrent laryngeal nerve monitoring. Minim Invasive Ther Allied Technol 2007;16:149–54
  11. Schneider R, Lorenz K, Machens A, Thanh PN, Randolph GW, Dralle H. Continuous intraoperative neuromonitoring (CIONM) of the recurrent laryngeal nerve. In: Randolph GW, editor. The Recurrentand Superior Laryngeal Nerves. 1st ed. Switzerland: Springer International Publishing AG; 2016. p. 169–83
  12. International Neural Monitoring Study Group (INMSG). Available at: http://www.inmsg.org. Accessed Jun 07, 2021
  13. Barczyński M, Randolph GW, Cernea CR, Dralle H, Dionigi G, Alesina PF, et al; International Neural Monitoring Study Group. External branch of the superior laryngeal nerve monitoring during thyroid and parathyroid surgery: International Neural Monitoring