The Effect of Noise Meters Giving Visual and Auditory Alarms Used on Reducing Noise in Neonatal Intensive Care Unit

Pages
456–461
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results: It was found that the total mean noise level in group 1 was significantly lower than group 2 for the two weeks (p 0.05).

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: This study was conducted to determine the effect of the use of a noise meter emitting visual and auditory alarms on reducing noise.
📊
Key Findings & Data:In the study, a noise meter emitting visual and auditory alarms and a digital noise meter were placed in a room (group 1); whereas, in the other room, only a digital noise meter was placed (group 2).
💡
Conclusion & Impact:Results: It was found that the total mean noise level in group 1 was significantly lower than group 2 for the two weeks (p 0.05).
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Aim: This study was conducted to determine the effect of the use of a noise meter emitting visual and auditory alarms on reducing noise. Materials and Methods: The study was conducted in an experimental design in a hospital in a Neonatal Intensive Care Unit (NICU). In the study, a noise meter emitting visual and auditory alarms and a digital noise meter were placed in a room (group 1); whereas, in the other room, only a digital noise meter was placed (group 2). The noise meter emitting visual and auditory alarms was hung on the most visible wall in the room and thus visual and auditory alarms were provided to the staff members in the room. The digital noise meter was hidden behind a closet in the same area in both rooms. The noise levels of the rooms were measured via the digital noise meter in both rooms in a way that data would come in continuously for two weeks. Results: It was found that the total mean noise level in group 1 was significantly lower than group 2 for the two weeks (p 0.05). Conclusion: The use of a noise meter emitting visual and auditory alarms might be effective in reducing noise in NICUs.

🔖

Cite This Article

BALCI, S., İNCEKAR, M. Ç., TAŞTEKİN, A. (2021). The Effect of Noise Meters Giving Visual and Auditory Alarms Used on Reducing Noise in Neonatal Intensive Care Unit. The Journal of Pediatric Research, Cilt: 8 - Sayı: 4, 456–461. https://ajindex.com/articles/362726

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Symington A, Pinelli J. Developmental care for promoting developmental and preventing morbidity in preterm infants. Cochrane Database Syst Rev 2006; 19:CD001814
  2. Coughlin M, Gibbins S, Hoath S. Core measures for developmentally supportive care in neonatal intensive care units: theory, precedence and practice. J Adv Nurs 2009; 65:2239-48
  3. Akçay Didişen N. Travma bilgisi içeren yaşa uygun bakım. İçinde: Başbakkal, Z, Yardımcı, F, Akçay Didişen, N (editörler). Yenidoğan Yoğun Bakım Ünitelerinde Dönüşümsel Hemşirelik. Ankara, Nobel, 2016
  4. Coughlin M. Transformative Nursing in the NICU: Traumainformed Age-Appropriate Care. New York, Springer Publishing Company, 2014
  5. Coughlin M. Trauma-informed, neuroprotective car efor hospitalised newborns and infants. Infant 2017; 13:176-9
  6. Noise: a hazard for the fetus and newborn. American Academy of Pediatrics. Committee on Environmental Health. Pediatrics 1997; 100:724-7
  7. Calikusu Incekar M, Balci S. The effect of training on noise reduction in neonatal intensive care units. J Spec Pediatr Nurs 2017; 22:1-8
  8. Çalıkuşu İncekar M, Çeçen E, Balcı S, Mutlu B, Ulu Öğüt N, Hamilçıkan Ş. The effect of education in reducing noise on health personnels’ knowledge level and behavioral change. J Turk Soc Intens Care 2019; 17:31-7
  9. Disher TC, Benoit B, Inglis D, et al. Striving for Optimum Noise- Decreasing Strategies in Critical Care: Initial Measurements and Observations. J Perinat Neonatal Nurs 2017; 31:58-66
  10. Gomes ELFD, Santos CMD, Santos ADCS, et al. Autonomic responses of premature newborns to body position and environmental noise in the neonatal intensive care unit. Rev Bras Ter Intensiva 2019; 31:296-302
  11. Kol E, İlaslan E, İnce S. Noise Sources and Levels in Intensive Care Units. J Turk Soc Intens Care 2015; 13:122-8
  12. Cardoso SM, Kozlowski Lde C, Lacerda AB, Marques JM, Ribas A. Newborn physiological responses to noise in the neonatal unit. Braz J Otorhinolaryngol 2015; 81:583-8
  13. Khalesi N, Khosravi N, Ranjbar A, Godarzi Z, Karimi A. The effectiveness of earmuffs on the physiologic and behavioral stability in preterm infants. Int J Pediatr Otorhinolaryngol 2017; 98:43-7
  14. Williams AL, Sanderson M, Lai D, Selwyn BJ, Lasky RE. Intensive care noise and mean arterial blood pressure in extremely lowbirth- weight neonates. Am J Perinatol 2009; 26:323-9
  15. Long JG, Lucey JF, Philip AG. Noise and hypoxemia in the intensive care nursery. Pediatrics 1980; 65:143-5
  16. Perlman JM, Volpe J