Journals / The European Research Journal / 2020 / Cilt: 6 - Sayı: 6

A perspective of biometric, visual and refractive outcomes of cataract surgery: a report of an ophthalmologist in compulsory governmental service

Pages
647–654
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

These results may be helpful in calculating intraocular lens power and evaluating refractive error for young ophthalmologists who have to work with ultrasound biometry in compulsory service.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: Knowledge of normal values of biometric parameters in cohort and relationships of them is helpful for ophthalmologists who want to achieve successful results.
📊
Key Findings & Data:Preoperative biometric and postoperative refractive data including axial length (AL), mean keratometry (K), anterior chamber depth (ACD), astigmatism, lens thickness (LT) of 310 patients who had cataract surgery were reviewed.
💡
Conclusion & Impact:These results may be helpful in calculating intraocular lens power and evaluating refractive error for young ophthalmologists who have to work with ultrasound biometry in compulsory service.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Cataract · biometric parameters · Turkish population

Abstract

Objectives: Knowledge of normal values of biometric parameters in cohort and relationships of them is helpful for ophthalmologists who want to achieve successful results. The aim of this study is to define these parameters in the light of experiences of an individual cataract surgeon after her residency program. Methods: This is a retrospective, register-based study. Preoperative biometric and postoperative refractive data including axial length (AL), mean keratometry (K), anterior chamber depth (ACD), astigmatism, lens thickness (LT) of 310 patients who had cataract surgery were reviewed. Ultrasound and optical biometry were used to evaluate the biometric parameters of the eyes. Results: 0.5 D of refractive target (RT) was obtained in 52.1% (186 eyes) of eyes, 1.0 D of RT in 82.20% (293 eyes) and 2.0 D of RT in 98.3% (351 eyes). Analyses of visual acuity show that 43.7% and 86.3% of eyes reached 0.00 and 0.30 log MAR or better. Age, ACD, LT, AL, preoperative corrected distance visual acuity, preoperative astigmatism and preoperative K were correlated between each other significantly (p < 0.001). The longer AL was found associated with older age (β = .745, p = 0.003), and lower K (β = -0.327, p < 0.001). A significant association between K value and older age (β = .680, p = .029) and shorter AL (β = -.660, p < 0.001) was seen. Conclusions: These data show the normative parameters of biometry values for the Turkish population. These results may be helpful in calculating intraocular lens power and evaluating refractive error for young ophthalmologists who have to work with ultrasound biometry in compulsory service.

🔖

Cite This Article

YEŞİLKAYA, E. C. (2020). A perspective of biometric, visual and refractive outcomes of cataract surgery: a report of an ophthalmologist in compulsory governmental service. The European Research Journal, Cilt: 6 - Sayı: 6, 647–654. https://ajindex.com/articles/360971

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Low SA, Braga-Mele R, Yan DB, El-Defrawy S. Intraoperative complication rates in cataract surgery performed by ophthalmology resident trainees compared to staff surgeons in a Canadian academic center. J Cataract Refract Surg 2018;44:1344-9
  2. Seitz B, Langenbucher A. Intraocular lens power calculation in eyes after corneal refractive surgery. J Refract Surg 2000;16:349-61
  3. Simsek A. Biometric and intraocular pressure changes after Nd: YAG laser capsulotomy. Eur Res J 2017;3:140-4
  4. Krysik K, Lyssek-Boron A, Janiszewska-Bil D, Wylegala E, Dobrowolski D. Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus. Int J Ophthalmol 2019;12:949-53
  5. Amritanand A, Simha AR, Baglari R, Roselin J, Michael J, Mahasampath G. Agreement of axial length measurements by three different biometric devices. J Clin Diagn Res 2018;12:NC01-NC04
  6. Cartwright NK, Johnston R, Jaycock P, Tole D, Sparrow J. The Cataract National Dataset electronic multicentre audit of 55 567 operations: when should IOLMaster biometric measurements be rechecked? Eye 2010;24:894-900
  7. Day A, Donachie P, Sparrow J, Johnston R. The Royal College of Ophthalmologists’ National Ophthalmology Database study of cataract surgery: report 1, visual outcomes and complications. Eye 2015;29:552-60
  8. Narendran N, Jaycock P, Johnston R, Taylor H, Adams M, Tole D et al. The Cataract National Dataset electronic multicentre audit of 55 567 operations: risk stratification for posterior capsule rupture and vitreous loss. Eye 2009;23:31-7
  9. Bikbov M, Fayzrakhmanov RR, Kazakbaeva G, Jonas JB. Ural Eye and Medical Study: description of study design and methodology, Ophthalmic Epidemiol 2018;25:187-98
  10. Varma R, Paz SH, Azen SP, Klein R, Globe D, Torres M et al, L.A.L.E.S. Group. The Los Angeles Latino Eye Study: Design, methods, and baseline data. Ophthalmology 2004;111:1121-31
  11. Yin G, Wang YX, Zheng ZY, Yang H, Xu L, Jonas JB, B.E.S. Group. Ocular axial length and its associations in Chinese: the Beijing Eye Study. PloS One 2012;7:e43172
  12. Ferreira TB, Hoffer KJ, Ribeiro F, Ribeiro P, O’Neill JG. Ocular biometric measurements in cataract surgery candidates in Portugal. PloS One 2017;12:e0184837
  13. Hashemi H, Khabazkhoob M, Miraftab M, Emamian MH, Shariati M, Abdolahinia T, et al. The distribution of axial length, anterior chamber depth, lens thickness, and vitreous chamber depth in an adult population of Shahroud, Iran.