Journals / The European Research Journal / 2019 / Cilt: 5 - Sayı: 2

A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation

Pages
407–409
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

We describe a case where a coronary stent was placed to stabilize the lead against the vessel wall.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:During cardiac resynchronization therapy implantation, left ventricular lead placement involves transvenous placement of leads via the coronary sinus and into a tributary branch.
📊
Key Findings & Data:At present, the most widely used method for left ventricular (LV) lead placement involves a transvenous LV lead placement via the coronary sinus into a tributary branch.
💡
Conclusion & Impact:We describe a case where a coronary stent was placed to stabilize the lead against the vessel wall.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Lead dislodgement · CRT · lead stabilization

Abstract

During cardiac resynchronization therapy implantation, left ventricular lead placement involves transvenous placement of leads via the coronary sinus and into a tributary branch. At present, the most widely used method for left ventricular (LV) lead placement involves a transvenous LV lead placement via the coronary sinus into a tributary branch. Lead dislodgement is a common cause for reoperation. We describe a case where a coronary stent was placed to stabilize the lead against the vessel wall.

🔖

Cite This Article

AGARWAL, D., MAKHİJA, A., MOHANTY, A., MANTRİ, R. R. (2019). A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation. The European Research Journal, Cilt: 5 - Sayı: 2, 407–409. https://ajindex.com/articles/359764

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Bulava A, Lukl J. Single-centre experiencewith coronary sinus lead stability and long-term pacing parameters. Europace 2007;9:523-7
  2. Fujii S, Tasaka H, Kawakami T, Mitsudo K, Takenada S. Stent placement to stabilize the left ventricularlead in the coronary sinus. J Arrhythm 2008;24:162-5
  3. Cesario DA, Shenoda M, Brar R, Shivkumar K. Left ventricular lead stabilization utilizing a coronary stent. Pacing Clin Electrophysiol 2006;29:427-8
  4. Szilagyi S, Merkely B, Roka A, Zima E, Fulop G, Kutyifa V, et al. Stabilization of the coronary sinus electrode position with coronary stent implantation to prevent and treat dislocation. J Cardiovasc Electrophysiol 2007;18:303-7
  5. Biffi M, Bertini M, Ziacchi M, Diemberger I, Martignani C, Boriani G. Left ventricular lead stabilization to retain cardiac resynchronization therapy at long term: when is it advisable? Europace 2014;16:533-40.